Journal of the Optical Society of America B

Nonlinear phase measurement using a coherent state in noisy environments

Bao-Hua Yang, Huajie Zou, Weijie Gu

Published Nov 18, 2021• 0 citations
Publisher

Abstract

Nonlinear phase measurement plays an important role in many dynamic processes. In this paper, we propose a single-mode measurement scheme for second-order nonlinear phase shifts that utilizes coherent states and homodyne measurement. The sensitivity at operating point φ = 0 is 1 / 4 N 3 / 2 with N photons on average and approaches the quantum Cramér–Rao bound. In addition, sensitivity with a small value of φ is discussed. For practical purposes, we analyze the effects of photon losses, thermal photon noise, and phase diffusion on sensitivities with φ = 0 as well as a small value of φ . The sensitivity still scales as 1 / N 3 / 2 in the presence of photon losses and thermal photon noise but degrades to the scaling of 1 / N with phase diffusion.

DOI
10.1364/josab.439500

Related papers

Nonlinear phase estimation via nonlinear-linear hybrid interferometers

Jiandong Zhang, Chuang Li, Shuai Wang

Estimating nonlinear phase shifts is useful to analyze many dynamical processes. In this work, with respect to the second-order nonlinear phase shifts, we propose an estimation scheme with a coherent state as the input and balanced homodyne detection as the readout strategy. The measurement setup is a nonlinear-linear hybrid interferometer composed of an optical parametric amplifier and a beam splitter. We analyze the precision and determine the optimal parameters of our scheme. The precision is compared with the quantum Cramér–Rao bound as well as the precision of a conventional nonlinear interferometer. In view of the fact that photon loss is ubiquitous, the effects of transmission loss and detection loss on the precision are addressed. At low gain, our scheme is superior to the scheme using a conventional nonlinear interferometer, and the precision can saturate the quantum Cramér–Rao bound.

Journal of the Optical Society of America B•Mar 21, 2022•5 citations

Phase sensitivity approaching the quantum Cramér-Rao bound in a modified SU(1,1) interferometer

Jiandong Zhang, Chenglong You, Chuang Li +1 more

SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second nonlinear element annihilates some of the photons inside. Here we focus on improving phase sensitivity and propose a different protocol based on a modified SU(1,1) interferometer, where the second nonlinear element is replaced by a beam splitter. We utilize two coherent states as inputs and implement balanced homodyne measurement at the output. Our analysis suggests that the protocol we propose can achieve the sub-shot-noise-limited phase sensitivity and is robust against photon loss as well as background noise. Our work is important for practical quantum metrology using SU(1,1) interferometers.

arXiv:2012.04236•Physical Review A•Mar 29, 2021•32 citations

Nonlinear phase estimation: Parity measurement approaches the quantum Cramér-Rao bound for coherent states

Jiandong Zhang, Zijing Zhang, Longzhu Cen +2 more

Quantum-enhanced phase estimation paves the way for precision measurements and is of great realistic significance. In this paper we theoretically investigate the second-order nonlinear phase estimation using a coherent state and parity measurement. A numerical expression of the parity signal is derived, and its visibility is analyzed. The resolution and sensitivity of the signal are compared to a linear phase estimation protocol with the same input and measurement. Additionally, by using the phase-averaging approach, we make an attempt at unveiling the lowdown on a conclusive sensitivity limit without external phase reference. Finally, the effects of several realistic scenarios on the resolution and sensitivity are studied, including photon loss, imperfect detector, those which are a combination thereof, and unbalanced beam splitter.

arXiv:1809.04821•Physical Review A•Feb 6, 2019•26 citations

Improving phase sensitivity of a hybrid interferometer with the two-mode squeezed coherent state

Tao Shao, Pengxiang Ruan, Minyang Zhang +4 more

Abstract We investigate the enhancement of phase sensitivity of a nonlinear-linear hybrid interferometer with the input of the two-mode squeezed coherent state (TMSCS). With the TMSCS produced by four-wave mixing, the quantum Cramér-Rao bounds (QCRB) can beat the Heisenberg limit (HL). Under the phase matched conditions, the optimal phase sensitivity with the balanced homodyne detection measurement can beat the HL and approach QCRB. The effects of internal and external losses on the measurement accuracy are also discussed. The results demonstrate that the scheme is robustness against to internal losses and this protocol can resist external detection loss which is up to 39%. Our results improve the performance of hybrid interferometers and this scheme can find important practical applications in quantum metrology.

Physica Scripta•Sep 18, 2024•5 citations

Precision bounds for noisy nonlinear quantum metrology

Marcin Zwierz, Howard M. Wiseman

We derive the ultimate bounds on the performance of nonlinear measurement schemes in the presence of noise. In particular, we investigate the precision of the second-order estimation scheme in the presence of the two most detrimental types of noise, photon loss and phase diffusion. We find that the second-order estimation scheme is affected by both types of noise in an analogous way as the linear one. Moreover, we observe that for both types of noise the gain in the phase sensitivity with respect to the linear estimation scheme is given by a multiplicative term $O(1/N)$. Interestingly, we also find that under certain circumstances, a careful engineering of the environment can, in principle, improve the performance of measurement schemes affected by phase diffusion.

arXiv:1309.2039•Physical Review A•Feb 11, 2014•14 citations

A nearly optimal and robust protocol for nonlinear phase estimation using coherent states

Jiandong Zhang, Zijing Zhang, Hu, Jun-Yan +4 more

We propose a protocol for the second-order nonlinear phase estimation with a coherent state as input and balanced homodyne detection as measurement strategy. The sensitivity is sub-Heisenberg limit, which scales as $N^{-3/2}$ for $N$ photons on average. By ruling out hidden resources in quantum Fisher information, the fundamental sensitivity limit is recalculated and compared to the optimal sensitivity of our protocol. In addition, we investigate the effect of photon loss on sensitivity, and discuss the robustness of measurement strategy. The results indicate that our protocol is nearly optimal and robust.

arXiv:1906.08995•Jun 21, 2019•0 citations
Nonlinear phase measurement plays an important role in many dynamic processes. In this paper, we propose a single-mode measurement scheme for second-order nonlinear phase shifts that utilizes coherent states and homodyne measurement. The sensitivity at operating point φ = 0 is 1 / 4 N 3 / 2 with N photons on average and approaches the quantum Cramér–Rao bound. In addition, sensitivity with a small value of φ is discussed. For practical purposes, we analyze the effects of photon losses, thermal photon noise, and phase diffusion on sensitivities with φ = 0 as well as a small value of φ . The sensitivity still scales as 1 / N 3 / 2 in the presence of photon losses and thermal photon noise but degrades to the scaling of 1 / N with phase diffusion.
Estimating nonlinear phase shifts is useful to analyze many dynamical processes. In this work, with respect to the second-order nonlinear phase shifts, we propose an estimation scheme with a coherent state as the input and balanced homodyne detection as the readout strategy. The measurement setup is a nonlinear-linear hybrid interferometer composed of an optical parametric amplifier and a beam splitter. We analyze the precision and determine the optimal parameters of our scheme. The precision is compared with the quantum Cramér–Rao bound as well as the precision of a conventional nonlinear interferometer. In view of the fact that photon loss is ubiquitous, the effects of transmission loss and detection loss on the precision are addressed. At low gain, our scheme is superior to the scheme using a conventional nonlinear interferometer, and the precision can saturate the quantum Cramér–Rao bound.
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second nonlinear element annihilates some of the photons inside. Here we focus on improving phase sensitivity and propose a different protocol based on a modified SU(1,1) interferometer, where the second nonlinear element is replaced by a beam splitter. We utilize two coherent states as inputs and implement balanced homodyne measurement at the output. Our analysis suggests that the protocol we propose can achieve the sub-shot-noise-limited phase sensitivity and is robust against photon loss as well as background noise. Our work is important for practical quantum metrology using SU(1,1) interferometers.
Quantum-enhanced phase estimation paves the way for precision measurements and is of great realistic significance. In this paper we theoretically investigate the second-order nonlinear phase estimation using a coherent state and parity measurement. A numerical expression of the parity signal is derived, and its visibility is analyzed. The resolution and sensitivity of the signal are compared to a linear phase estimation protocol with the same input and measurement. Additionally, by using the phase-averaging approach, we make an attempt at unveiling the lowdown on a conclusive sensitivity limit without external phase reference. Finally, the effects of several realistic scenarios on the resolution and sensitivity are studied, including photon loss, imperfect detector, those which are a combination thereof, and unbalanced beam splitter.
Abstract We investigate the enhancement of phase sensitivity of a nonlinear-linear hybrid interferometer with the input of the two-mode squeezed coherent state (TMSCS). With the TMSCS produced by four-wave mixing, the quantum Cramér-Rao bounds (QCRB) can beat the Heisenberg limit (HL). Under the phase matched conditions, the optimal phase sensitivity with the balanced homodyne detection measurement can beat the HL and approach QCRB. The effects of internal and external losses on the measurement accuracy are also discussed. The results demonstrate that the scheme is robustness against to internal losses and this protocol can resist external detection loss which is up to 39%. Our results improve the performance of hybrid interferometers and this scheme can find important practical applications in quantum metrology.
We derive the ultimate bounds on the performance of nonlinear measurement schemes in the presence of noise. In particular, we investigate the precision of the second-order estimation scheme in the presence of the two most detrimental types of noise, photon loss and phase diffusion. We find that the second-order estimation scheme is affected by both types of noise in an analogous way as the linear one. Moreover, we observe that for both types of noise the gain in the phase sensitivity with respect to the linear estimation scheme is given by a multiplicative term O(1/N)O(1/N)O(1/N). Interestingly, we also find that under certain circumstances, a careful engineering of the environment can, in principle, improve the performance of measurement schemes affected by phase diffusion.
We propose a protocol for the second-order nonlinear phase estimation with a coherent state as input and balanced homodyne detection as measurement strategy. The sensitivity is sub-Heisenberg limit, which scales as N−3/2N^{-3/2}N−3/2 for NNN photons on average. By ruling out hidden resources in quantum Fisher information, the fundamental sensitivity limit is recalculated and compared to the optimal sensitivity of our protocol. In addition, we investigate the effect of photon loss on sensitivity, and discuss the robustness of measurement strategy. The results indicate that our protocol is nearly optimal and robust.