Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America A

Second-order correlation and radiometry (A)

H. Baltes, B. Steinle

Published Oct 1, 1977• 0 citations
OpenAlex

Related papers

Radiometry and Coherence

H. Baltes, Jon Geist, A. Walther

Topics in current physics•Jan 1, 1978•19 citations

A Molecule‐Based Single‐Photon Source Applied in Quantum Radiometry

Pietro Lombardi, Marco Trapuzzano, Maja Colautti +5 more

Abstract Single‐photon sources (SPSs) based on quantum emitters hold promise in quantum radiometry as metrology standard for photon fluxes at the low light level. Ideally this requires control over the photon flux in a wide dynamic range, sub‐Poissonian photon statistics, and narrow‐band emission spectrum. In this work, a monochromatic SPS based on an organic dye molecule is presented, whose photon flux is traceably measured to be adjustable between 144 000 and 1320 000 photons per second at a wavelength of (785.6 ± 0.1) nm, corresponding to an optical radiant flux between 36.5 and 334 fW. The high purity of the single‐photon stream is verified, with a second‐order autocorrelation function at zero time delay below 0.1 throughout the whole range. Such molecule‐based SPS is hence used for the calibration of a single‐photon avalanche detector against a low‐noise analog photodiode traceable to the primary standard for optical radiant flux (i.e., the cryogenic radiometer). Due to the narrow bandwidth of the source, corrections to the detector efficiency arising from the spectral power distribution are negligible. With this major advantage, the developed device may finally realize a low‐photon‐flux standard source for quantum radiometry.

arXiv:1908.00616•Advanced Quantum Technologies•Oct 22, 2019•41 citations

Incoherent Light and Second-order correlation

Elsevier eBooks•Aug 28, 2026•0 citations

Quantum non-demolition measurement of the photon number: an application to radiometry

Stefania Castelletto, Ivo Pietro Degiovanni, Maria Luisa Rastello

This paper proposes a realistically feasible experiment, within the realm of existing technology and proved techniques, to measure the mean photon number of a coherent source by means of a quantum non-demolition scheme, exploiting the parametric amplification of correlated photons in χ (2) media. We deduce the number of photons of an input source interacting with a high-intensity pump field in a nonlinear crystal, using as the probe the shift in the quadrature amplitude of the pump beam induced by the source under measurement. We perform a theoretical evaluation of the noise level associated with this measurement and compare it with the quantum limit. We explore the possible implications of this method for radiometry.

Journal of Optics B Quantum and Semiclassical Optics•Feb 1, 2001•2 citations

Toward the Realization of Single-Photon Sources for Radiometry Applications at Room Temperature

Kee Suk Hong, Hee‐Jin Lim, Dong-Hoon Lee +5 more

Single photon sources based on single emitters such as 2D materials and impurities in diamond are of great interest for many application fields including quantum communication, quantum metrology and quantum sensing. In photometry and radiometry, a single photon source, having the ability to emit only one photon in a well-defined time and frequency domain, represents a promising candidate to realize a photon number-based primary standard for quantum radiometry. At the Korea Research Institute of Standards and Science (KRISS), we have realized three kinds of single photon sources based on various single emitters at room temperature: silicon vacancy in diamond, defects in gallium nitride (GaN), and vacancy in hexagonal boron nitride (hBN). We found common factors related with the relaxation times of the internal states that indirectly affect the photon number stability. We observed a high photon number stability in the GaN emitter due to faster relaxation times compared with the hBN emitter, which on the other hand produced high rates of photons per second (> 106). Moreover, we demonstrate repeatable radiant flux measurements of a bright hBN single photon emitter for a wide radiant flux range from a few tens of femtowatts to one picowatt.

arXiv:2007.10616•IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•3 citations

Photon correlation methods

Edward R. Pike

•Jan 1, 1974•2 citations
Abstract Single‐photon sources (SPSs) based on quantum emitters hold promise in quantum radiometry as metrology standard for photon fluxes at the low light level. Ideally this requires control over the photon flux in a wide dynamic range, sub‐Poissonian photon statistics, and narrow‐band emission spectrum. In this work, a monochromatic SPS based on an organic dye molecule is presented, whose photon flux is traceably measured to be adjustable between 144 000 and 1320 000 photons per second at a wavelength of (785.6 ± 0.1) nm, corresponding to an optical radiant flux between 36.5 and 334 fW. The high purity of the single‐photon stream is verified, with a second‐order autocorrelation function at zero time delay below 0.1 throughout the whole range. Such molecule‐based SPS is hence used for the calibration of a single‐photon avalanche detector against a low‐noise analog photodiode traceable to the primary standard for optical radiant flux (i.e., the cryogenic radiometer). Due to the narrow bandwidth of the source, corrections to the detector efficiency arising from the spectral power distribution are negligible. With this major advantage, the developed device may finally realize a low‐photon‐flux standard source for quantum radiometry.
This paper proposes a realistically feasible experiment, within the realm of existing technology and proved techniques, to measure the mean photon number of a coherent source by means of a quantum non-demolition scheme, exploiting the parametric amplification of correlated photons in χ (2) media. We deduce the number of photons of an input source interacting with a high-intensity pump field in a nonlinear crystal, using as the probe the shift in the quadrature amplitude of the pump beam induced by the source under measurement. We perform a theoretical evaluation of the noise level associated with this measurement and compare it with the quantum limit. We explore the possible implications of this method for radiometry.
Single photon sources based on single emitters such as 2D materials and impurities in diamond are of great interest for many application fields including quantum communication, quantum metrology and quantum sensing. In photometry and radiometry, a single photon source, having the ability to emit only one photon in a well-defined time and frequency domain, represents a promising candidate to realize a photon number-based primary standard for quantum radiometry. At the Korea Research Institute of Standards and Science (KRISS), we have realized three kinds of single photon sources based on various single emitters at room temperature: silicon vacancy in diamond, defects in gallium nitride (GaN), and vacancy in hexagonal boron nitride (hBN). We found common factors related with the relaxation times of the internal states that indirectly affect the photon number stability. We observed a high photon number stability in the GaN emitter due to faster relaxation times compared with the hBN emitter, which on the other hand produced high rates of photons per second (> 106). Moreover, we demonstrate repeatable radiant flux measurements of a bright hBN single photon emitter for a wide radiant flux range from a few tens of femtowatts to one picowatt.