Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

High precision measurements of atomic number densities

W. T. Hill, Kiyoshi Ueda

Published Jan 1, 1985• 0 citations
Publisher

Abstract

A quick and simple technique for determining line of sight number densities in atomic vapor ovens will be presented. The technique is based on measuring the frequency-dependent distortion of interference fringe profiles which is produced when an absorbing vapor is placed in one arm of a Mach-Zehnder interferometer. In contrast to previous interferometric methods, in which only the peak intensity positions of the fringes are measured, this method relies on measuring the entire intensity profiles of the fringes. This is made possible by placing a 1024-channel diode array detector at the exit plane of a spectrograph. The density is then determined with a precision of 1 % or better by fitting the experimental data to a simple analytic expression.

DOI
10.1364/oam.1985.fn4

Related papers

Column-density meter: a high precision technique for measuring line-of-sight vapor densities

W. T. Hill

A technique suitable for making automated high precision (1%) measurements of column densities Nl in vapor cells and ovens will be presented. The method employs a single-pass low finesse interferometer (e.g., a Mach-Zehnder), a broadband light source, and a 1024-element diode array in the image plane of a stigmatic spectrograph to measure photometrically the frequency-dependent intensity profiles of distorted interference fringes produced by the anomalous dispersion near an absorption line. Experimental measurements of Ba, Ca, and Li column densities show that Nl can be determined with high precision by numerically fitting a small segment (5–20 nm) of the spectrum to a simple analytic expression describing the intensity.

Applied Optics•Dec 1, 1986•13 citations

Nondestructive interferometric characterization of an optical dipole trap

Plamen G. Petrov, Daniel Oblak, Carlos L. Garrido Alzar +2 more

A method for nondestructive characterization of a dipole-trapped atomic sample is presented. It relies on a measurement of the phase shift imposed by cold atoms on an optical pulse that propagates through a free-space Mach-Zehnder interferometer. Using this technique we are able to determine, with very good accuracy, relevant trap parameters such as the atomic sample temperature, trap oscillation frequencies, and loss rates. Another important feature is that our method is faster than conventional absorption or fluorescence techniques, allowing the combination of high-dynamical range measurements and a reduced number of spontaneous emission events per atom.

arXiv:quant-ph/0610107•Physical Review A•Mar 6, 2007•27 citations

Precision atom interferometry

Achim Peters, Keng Yeow Chung, Brent C. Young +2 more

The basic physical principles behind atom interferometers based on optical pulses of light are summarized. This method of atom interferometry is based on measurements in the time and frequency domain and is an inherently precise measurement technique. After a brief discussion of some of the important technical requirements for good fringe accuracy and visibility, we describe an interferometer that has measured the acceleration of an atom due to gravity with a resolution better than one part in 1010. We project that the absolute accuracy of our measurement will be of the order of a few parts in 109. We also describe an interferometer experiment that measures the recoil energy shift of an atom when it absorbs a photon. When combined with the value of the Rydberg constant and the mass ratios MCs/mp and mp/me, one can obtain a value for α, the fine structure constant. Currently, we have an experimental resolution Δα/α ∼ 10-8 after two hours of integration time and are studying the systematic effects that affect the measurement.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Dec 15, 1997•80 citations

A New Technique for Measuring Atomic Recoil Frequency Using Coherence Functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Bulletin of the American Physical Society•May 22, 2009•0 citations

Technique for measuring atomic recoil frequency using coherence functions

Scott Beattie, B. Barrett, I. Y. Chan +3 more

We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.

Physical Review A•Feb 13, 2009•13 citations

Measurement of the refraction index for atom waves

Marion Jacquey, M Büchner, G. Trénec +1 more

We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.

Annales de Physique•Jan 1, 2007•0 citations
A quick and simple technique for determining line of sight number densities in atomic vapor ovens will be presented. The technique is based on measuring the frequency-dependent distortion of interference fringe profiles which is produced when an absorbing vapor is placed in one arm of a Mach-Zehnder interferometer. In contrast to previous interferometric methods, in which only the peak intensity positions of the fringes are measured, this method relies on measuring the entire intensity profiles of the fringes. This is made possible by placing a 1024-channel diode array detector at the exit plane of a spectrograph. The density is then determined with a precision of 1 % or better by fitting the experimental data to a simple analytic expression.
A technique suitable for making automated high precision (1%) measurements of column densities Nl in vapor cells and ovens will be presented. The method employs a single-pass low finesse interferometer (e.g., a Mach-Zehnder), a broadband light source, and a 1024-element diode array in the image plane of a stigmatic spectrograph to measure photometrically the frequency-dependent intensity profiles of distorted interference fringes produced by the anomalous dispersion near an absorption line. Experimental measurements of Ba, Ca, and Li column densities show that Nl can be determined with high precision by numerically fitting a small segment (5–20 nm) of the spectrum to a simple analytic expression describing the intensity.
A method for nondestructive characterization of a dipole-trapped atomic sample is presented. It relies on a measurement of the phase shift imposed by cold atoms on an optical pulse that propagates through a free-space Mach-Zehnder interferometer. Using this technique we are able to determine, with very good accuracy, relevant trap parameters such as the atomic sample temperature, trap oscillation frequencies, and loss rates. Another important feature is that our method is faster than conventional absorption or fluorescence techniques, allowing the combination of high-dynamical range measurements and a reduced number of spontaneous emission events per atom.
The basic physical principles behind atom interferometers based on optical pulses of light are summarized. This method of atom interferometry is based on measurements in the time and frequency domain and is an inherently precise measurement technique. After a brief discussion of some of the important technical requirements for good fringe accuracy and visibility, we describe an interferometer that has measured the acceleration of an atom due to gravity with a resolution better than one part in 1010. We project that the absolute accuracy of our measurement will be of the order of a few parts in 109. We also describe an interferometer experiment that measures the recoil energy shift of an atom when it absorbs a photon. When combined with the value of the Rydberg constant and the mass ratios MCs/mp and mp/me, one can obtain a value for α, the fine structure constant. Currently, we have an experimental resolution Δα/α ∼ 10-8 after two hours of integration time and are studying the systematic effects that affect the measurement.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency r as a function of the time at which the third pulse is applied, allowing r to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We have developed a technique for measuring the atomic recoil frequency using a single-state echo-type atom interferometer that manipulates laser-cooled atoms in the ground state. The interferometer relies on momentum-state interference due to two standing-wave pulses that produce density gratings. The interference is modified by applying a third standing-wave pulse during the interferometer pulse sequence. As a result, the grating contrast exhibits periodic revivals at the atomic recoil frequency ${\ensuremath{\omega}}_{r}$ as a function of the time at which the third pulse is applied, allowing ${\ensuremath{\omega}}_{r}$ to be measured easily and precisely. The contrast is accurately described by a coherence function, which is the Fourier transform of the momentum distribution, produced by the third pulse and by the theory of echo formation. If the third pulse is a traveling wave, loss of grating contrast is observed, an effect also described by a coherence function. The decay of the grating contrast as a function of continuous-wave light intensity is used to infer the cross section for photon absorption.
We have developed a Mach-Zehnder atom interferometer which uses elastic diffraction of lithium atom on laser standing waves for the coherent manipulation of the atom wave. The interference signal is of sufficient quality to achieve a phase sensitivity near 10 milliradians/. With this apparatus, we have recently measured the index of refraction of several gases for lithium waves. The interference signals give access to the real and imaginary parts of () and we have tested the linear dependence of these two quantities with gas density. The measured values of () are in good agreement with calculations and they exhibit glory oscillations, as predicted by theory.