IEEE Sensors Journal

Suppression Method of Light Shift in K-Rb Hybrid Optical Pumping SERF Atomic Comagnetometer

Feng Liu, Lihong Duan, Wenfeng Fan, Haoying Pang, Sixun Liu, Jiaqi Wu, Wei Quan

Published Oct 26, 2021• 14 citations
Publisher

Abstract

The light shift generated by the circularly polarized light leads to an error in the spin-exchange relaxation-free (SERF) comagnetometer, since it turns the fluctuations of the pumping light frequency and intensity into a drift in the SERF comagnetometer. Moreover, the light shift is a source of cross-talk effect between the two sensitive axes. Firstly, the relationship between the vapor cell temperature and the total light shift felt by Rb atoms in the K-Rb hybrid pumping SERF comagnetometer is formulated and simulated. It is found that the total light shift is the result of the collision mixing of K and Rb ac Stark shifts and the increase of cell temperature makes the light shift of K felt by Rb dominate the total light shift. Furthermore, different from the method of adjusting the frequency of laser, a new method that suppresses the total light shift in hybrid pumping by adjusting the cell temperature is proposed and experimentally verified. The total light shift at 165.7°C is -0.00152 nT experimentally, which is 3 orders of magnitude smaller than that at 185.0°C, indicating that it can be suppressed effectively by adjusting the cell temperature. The method does not require any extra hardware or sacrifice the pumping efficiency and can be applied to suppress the error induced by the pumping light and the cross-talk effect between the axes. In addition, the relationship between total relaxation rate and cell temperature is briefly discussed.

DOI
10.1109/jsen.2021.3122990

Related papers

Suppression Method of AC-Stark Shift in SERF Atomic Magnetometer

Yang Li, Ming Ding, Xuejing Liu +3 more

In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.

IEEE photonics journal•Sep 27, 2018•21 citations

Suppression of the vapor cell temperature error in a spin-exchange relaxation-free comagnetometer

Jiali Liu, Liwei Jiang, Chi Fang +2 more

Abstract The fluctuation of the vapor cell temperature leads to the variations of the density of the alkali metal atoms, which seriously damages the long-term stability of the spin-exchange relaxation-free (SERF) comagnetometer. To address this problem, we propose a novel method for suppressing the cell temperature error by manipulating the probe laser frequency. A temperature coefficient model of the SERF comagnetometer is established based on the steady-state response, which indicates that the comagnetometer can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, and the working point is determined by the relaxation rate of the alkali metal atoms. The method is verified in a K−Rb− 21Ne comagnetometer, and the experimental results are consistent with the theory. The theory and method presented here lay a foundation for the practical applications of the SERF comagnetometer.

Chinese Physics B•Oct 9, 2024•4 citations

Rotation sensing decoupling of a dual-axis K-Rb-21Ne atomic comagnetometer

Lihong Duan, Wei Quan, Yao Chen +5 more

A dual-axis atomic comagnetometer can sense the angular rotation of two measurement axes simultaneously and independently. However, there is a cross-talk coupling effect between the two axes because of the residual magnetic field and the light shift arising from the pumping laser. Here, we propose a scheme to eliminate the rotation coupling of dual-axis K-Rb-N21e atomic comagnetometers. The residual magnetic field can be effectively removed by controlling the comagnetometer at the magnetic compensation point and the magnetic shielding layer. The light shift could be eliminated by using the K atom light shift to counteract the Rb atom light shift, in which the light shift of K atoms was optimized to the decoupling point by finely adjusting the pumping laser wavelength of the K D1 line. The feasibility and efficiency of this decoupling scheme have been experimentally verified. The output response of the coupling axis is reduced by two orders of magnitude compared to the sensitive axis. This scheme can also be applied to any atomic comagnetometer with hybrid optical pumping that experiences cross-talk coupling.

Applied Optics•Feb 22, 2018•9 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•2 citations

Balanced Light-Assisted Hybrid Spin Exchange Optical Pumping in SERF Comagnetometers

Zitong Xu, Kai Wei, Xiaofei Huang +7 more

Ultrasensitive spin exchange relaxation-free (SERF) comagnetometers have been widely applied in various new physics experiments and show great potential for inertial navigation. However, the spatially nonuniform spin polarization of alkali metal (AM) and noble gas (NG) atoms results in an effective magnetic field gradient on the order of 100 nT/cm which is much larger than that is produced by the coils and remanence on the magnitude of 1 nT/cm, thereby reducing the suppression ability of the magnetic noise and limiting the scale factor and noise floor of the comagnetometers. In this study, we establish a model of the effective magnetic field gradient caused by uneven spin polarization and analyze the influencing factors. Our results indicate that optimizing the density ratio of hybrid AM atoms can suppress the effective magnetic field gradient. Nevertheless, the available pump light power imposes a limitation on the density ratio. To further address this issue, we propose a balanced light-assisted hybrid spin exchange optical pumping (HSEOP) method. Our experimental results confirm the effectiveness of the mentioned approach, with 67% suppression of the nuclear transverse relaxation rate and a nearly threefold increase in the scale factor. Furthermore, the optimal density ratio in experimental applications can be reduced from 200 to below 80, thereby overcoming the limitation of laser power in SERF comagnetometers and providing the possibility for wider applications. Finally, the suppression factor of magnetic noise is enhanced by 89% by optimizing the density ratio and the balanced light-assisted HSEOP method. This research sheds light on the fundamental physics experiments and potential for inertial navigation.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•5 citations

Analysis and Suppression of the Pump Light Intensity Error in the K–Rb– 21 Ne Atomic Spin Comagnetometer

Jiale Quan, Ye Liu, Longyan Ma +5 more

As a novel quantum sensor utilizing atomic spin coupling mechanisms, spin-exchange relaxation-free (SERF) comagnetometers demonstrate promising applications in precision metrology such as magnetic field and rotation sensing. However, the ultra-high precision measurement capability exhibits vulnerability to multiple disturbance factors, with pump light intensity fluctuations emerging as a critical instability source that compromises operational reliability during prolonged measurements. In this paper, a model-driven paradigm for pump light intensity error suppression in SERF comagnetometers is proposed. The nonlinear dynamics are rigorously linearized via Taylor expansion within their valid range to construct a state-space model, ultimately deriving the pump light intensity frequency response model. The proposed methodology undergoes experimental validation on a K-Rb-21Ne comagnetometry platform, confirming the predictive capability for stability degradation mechanisms. Through theoretical analysis and experimental verification, this study reveals that magneto-optical non-orthogonality, which introduces a differential component in the light intensity transfer function, creates an approximate proportional relationship between the output signal and pump light intensity within the operating bandwidth. Light intensity noise is decomposed, and light intensity errors are quantitatively evaluated via the frequency response model. To address this critical issue affecting inertial measurement accuracy, a closed-loop control-based suppression method with optimized feedback gain is proposed. By dynamically adjusting the closed-loop feedback gain through real-time intensity monitoring, the intensity instability associated with optical pumping is suppressed from 0.56% to 0.14%, concomitant with a 2.8-fold improvement in the long-term stability of the SERF comagnetometer.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•2 citations
The light shift generated by the circularly polarized light leads to an error in the spin-exchange relaxation-free (SERF) comagnetometer, since it turns the fluctuations of the pumping light frequency and intensity into a drift in the SERF comagnetometer. Moreover, the light shift is a source of cross-talk effect between the two sensitive axes. Firstly, the relationship between the vapor cell temperature and the total light shift felt by Rb atoms in the K-Rb hybrid pumping SERF comagnetometer is formulated and simulated. It is found that the total light shift is the result of the collision mixing of K and Rb ac Stark shifts and the increase of cell temperature makes the light shift of K felt by Rb dominate the total light shift. Furthermore, different from the method of adjusting the frequency of laser, a new method that suppresses the total light shift in hybrid pumping by adjusting the cell temperature is proposed and experimentally verified. The total light shift at 165.7°C is -0.00152 nT experimentally, which is 3 orders of magnitude smaller than that at 185.0°C, indicating that it can be suppressed effectively by adjusting the cell temperature. The method does not require any extra hardware or sacrifice the pumping efficiency and can be applied to suppress the error induced by the pumping light and the cross-talk effect between the axes. In addition, the relationship between total relaxation rate and cell temperature is briefly discussed.
In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.
Abstract The fluctuation of the vapor cell temperature leads to the variations of the density of the alkali metal atoms, which seriously damages the long-term stability of the spin-exchange relaxation-free (SERF) comagnetometer. To address this problem, we propose a novel method for suppressing the cell temperature error by manipulating the probe laser frequency. A temperature coefficient model of the SERF comagnetometer is established based on the steady-state response, which indicates that the comagnetometer can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, and the working point is determined by the relaxation rate of the alkali metal atoms. The method is verified in a K−Rb− 21Ne comagnetometer, and the experimental results are consistent with the theory. The theory and method presented here lay a foundation for the practical applications of the SERF comagnetometer.
A dual-axis atomic comagnetometer can sense the angular rotation of two measurement axes simultaneously and independently. However, there is a cross-talk coupling effect between the two axes because of the residual magnetic field and the light shift arising from the pumping laser. Here, we propose a scheme to eliminate the rotation coupling of dual-axis K-Rb-N21e atomic comagnetometers. The residual magnetic field can be effectively removed by controlling the comagnetometer at the magnetic compensation point and the magnetic shielding layer. The light shift could be eliminated by using the K atom light shift to counteract the Rb atom light shift, in which the light shift of K atoms was optimized to the decoupling point by finely adjusting the pumping laser wavelength of the K D1 line. The feasibility and efficiency of this decoupling scheme have been experimentally verified. The output response of the coupling axis is reduced by two orders of magnitude compared to the sensitive axis. This scheme can also be applied to any atomic comagnetometer with hybrid optical pumping that experiences cross-talk coupling.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.
Ultrasensitive spin exchange relaxation-free (SERF) comagnetometers have been widely applied in various new physics experiments and show great potential for inertial navigation. However, the spatially nonuniform spin polarization of alkali metal (AM) and noble gas (NG) atoms results in an effective magnetic field gradient on the order of 100 nT/cm which is much larger than that is produced by the coils and remanence on the magnitude of 1 nT/cm, thereby reducing the suppression ability of the magnetic noise and limiting the scale factor and noise floor of the comagnetometers. In this study, we establish a model of the effective magnetic field gradient caused by uneven spin polarization and analyze the influencing factors. Our results indicate that optimizing the density ratio of hybrid AM atoms can suppress the effective magnetic field gradient. Nevertheless, the available pump light power imposes a limitation on the density ratio. To further address this issue, we propose a balanced light-assisted hybrid spin exchange optical pumping (HSEOP) method. Our experimental results confirm the effectiveness of the mentioned approach, with 67% suppression of the nuclear transverse relaxation rate and a nearly threefold increase in the scale factor. Furthermore, the optimal density ratio in experimental applications can be reduced from 200 to below 80, thereby overcoming the limitation of laser power in SERF comagnetometers and providing the possibility for wider applications. Finally, the suppression factor of magnetic noise is enhanced by 89% by optimizing the density ratio and the balanced light-assisted HSEOP method. This research sheds light on the fundamental physics experiments and potential for inertial navigation.
As a novel quantum sensor utilizing atomic spin coupling mechanisms, spin-exchange relaxation-free (SERF) comagnetometers demonstrate promising applications in precision metrology such as magnetic field and rotation sensing. However, the ultra-high precision measurement capability exhibits vulnerability to multiple disturbance factors, with pump light intensity fluctuations emerging as a critical instability source that compromises operational reliability during prolonged measurements. In this paper, a model-driven paradigm for pump light intensity error suppression in SERF comagnetometers is proposed. The nonlinear dynamics are rigorously linearized via Taylor expansion within their valid range to construct a state-space model, ultimately deriving the pump light intensity frequency response model. The proposed methodology undergoes experimental validation on a K-Rb-21Ne comagnetometry platform, confirming the predictive capability for stability degradation mechanisms. Through theoretical analysis and experimental verification, this study reveals that magneto-optical non-orthogonality, which introduces a differential component in the light intensity transfer function, creates an approximate proportional relationship between the output signal and pump light intensity within the operating bandwidth. Light intensity noise is decomposed, and light intensity errors are quantitatively evaluated via the frequency response model. To address this critical issue affecting inertial measurement accuracy, a closed-loop control-based suppression method with optimized feedback gain is proposed. By dynamically adjusting the closed-loop feedback gain through real-time intensity monitoring, the intensity instability associated with optical pumping is suppressed from 0.56% to 0.14%, concomitant with a 2.8-fold improvement in the long-term stability of the SERF comagnetometer.