The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.
In the present study we extend and generalize previous results for coherent-state and squeezed-state Michelson interferometer quantum mechanical uncertainties (or fluctuations), which are commonly referred to as `quantum noise'. The calculation of photon counting (PC) fluctuations in the squeezed-state interferometer is extended to fourth-order correlation functions used as the measured signal. We also generalize a `unified model' for treating both PC and radiation pressure fluctuations in the coherent-state interferometer, by using mathematical methods which apply to Kerr-type interactions. The results are more general than those reported previously in two ways. First, we obtain exact expressions, which lead to previous results under certain approximations. Second, we deal with cases in which the responses of the two mirrors to radiation pressure are not equal.
In many quantum-mechanical measurements, the total uncertainties (\ensuremath{\sigma}) are greater than or equal to the intrinsic uncertainties (${\ensuremath{\sigma}}_{I}$) of the quantities to be measured; the differences are due to the particular measurement processes chosen. In each of these situations, a measurement uncertainty ${\ensuremath{\sigma}}_{M}$ can be defined as ${\ensuremath{\sigma}}_{M}$=(${\ensuremath{\sigma}}^{2}$-${\ensuremath{\sigma}}_{I}$
2)1/2. A question to ask is whether ${\ensuremath{\sigma}}_{M}$ is independent of the initial quantum state of the system to be measured, i.e., whether ${\ensuremath{\sigma}}_{M}$ is only dependent on the measurement process chosen. For a Michelson interferometer, we extend Loudon's model to show that in the model ${\ensuremath{\sigma}}_{M}$ is only dependent on the measurement process chosen for the case with small radiation-pressure fluctuation. When the intensity and radiation-pressure fluctuation are high, there are cross-correlated terms. Some of these terms are negative and give hope to the possibility of uncertainty reductions for appropriate schemes.
We discuss quantum measurements of position and repeated-measurement schemes for monitoring free-mass position to an arbitrary accuracy. Using these schemes, weak classical forces can be monitored to an arbitrary accuracy. To illustrate various measurement uncertainties and intrinsic uncertainties, we consider the case of a Michelson interferometer. In the low-intensity limit, two measurement uncertainties, photon counting error and radiation pressure error, are independent of the intrinsic uncertainty. The uses of squeezed states and number eigenstates are discussed.
The radiation pressure interaction of light with a mechanical oscillator leads to a fundamental disturbance on the oscillator. This disturbance - measurement backaction - is due to the quantum fluctuations in the amplitude of the light. When the phase of the light is detected to infer the mechanical position, quantum fluctuations in the phase - measurement imprecision - leads to a further uncertainty in the estimate of the position. In this conventional measurement strategy, these two noise sources impose a fundamental limit on the ability to estimate the position of the mechanical object - the so-called standard quantum limit [1]. However, the two noise contributions are in general correlated. The fluctuations in the amplitude quadrature drive the mechanical oscillator, and this backaction driven motion is transduced into the phase quadrature. Correlations thus established [2] form a valuable quantum mechanical resource that can be directly employed for back-action cancellation in the measurement record via “variational measurements” [3].
It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output [the photon number flux
N(t) entering the final photodetector] commutes with itself at different times in the Heisenberg picture, $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})]=0$ and thus can be regarded as classical. (ii) This number flux is linear to high accuracy in the test-mass initial position and momentum operators
xo and
po, and those operators influence the measured photon flux
N(t) in manners that can easily be removed by filtering. For example, in most interferometers
xo and
po appear in
N(t) only at the test masses' $\ensuremath{\sim}1\mathrm{Hz}$ pendular swinging frequency and their influence is removed when the output data are high-pass filtered to get rid of noise below $\ensuremath{\sim}10\mathrm{Hz}.$ The test-mass operators
xo and
po contained in the unfiltered output
N(t) make a nonzero contribution to the commutator $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})].$ That contribution is precisely canceled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in
N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations, and get identically the same result. These conclusions are all true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.