The Japan Society of Applied Physics

Effects of finite-width pulses in dynamical decoupling sequences on AC magnetometry using nitrogen-vacancy centers in a diamond

T. Ishikawa, Akio Yoshizawa, Satoshi Kashiwaya, Yasunori Mawatari, Hideyuki Watanabe

Published Jul 10, 2018• 0 citations
OpenAlex

Related papers

Preserving electron spin coherence by dynamical decoupling based on Nitrogen-Vacancy center in diamond

Jiangfeng Du

Bulletin of the American Physical Society•Mar 20, 2013•0 citations

Influence of Dynamical Decoupling Sequences with Finite-Width Pulses on Quantum Sensing for AC Magnetometry

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Dynamical decoupling sequences of multiple pulses offer filter functions for the time evolution of a qubit superposition state, and thus are indispensable tools for quantum sensing. The authors investigate the effects of sequences of finite-width pulses on ac magnetometry based on nitrogen-vacancy centers in isotopically controlled diamond. This experimental and theoretical study shows that finite pulse width alters the optimum acquisition time, and shows how to correct the resulting frequency shift, providing a guideline for accurate measurement of the frequency, linewidth, and amplitude of an ac field.

arXiv:1807.00946•Physical Review Applied•Nov 27, 2018•14 citations

Progress towards magnetometry with nitrogen-vacancy ensembles in diamond

Víctor M. Acosta, Erik Bauch, M. P. Ledbetter +1 more

Bulletin of the American Physical Society•May 22, 2009•0 citations

Finite-pulse-width effect on quantum sensing for an asynchronous alternating-current magnetic field to dynamical decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Quantum sensors based on the electron spin states of nitrogen vacancy centers in diamond have found wide application in magnetometry and nuclear spin magnetic resonance measurements. Previously, we have theoretically and experimentally investigated the effect of finite pulse width on quantum sensing for synchronous alternating-current (AC) magnetic fields to dynamical decoupling sequences [T. Ishikawa et al., Phys. Rev. Appl. 10, 054059 (2018)]. However, many biological and condensed-matter systems exhibit fluctuating AC fields over time, and thus, our model needs modifications because of additional non-ideal conditions in practical measurements. Here, we investigate the effects of finite pulse width of multiple-pulse decoupling sequences on quantum sensing for asynchronous AC magnetic fields. For this purpose, we use a spin ensemble of nitrogen vacancy centers in an isotopically purified diamond film. We reveal through experiments that the finite-width pulse causes shifts in AC magnetometry signals in a free-precession-time plot. In addition, our results indicate that the finite-width pulse affects the amplitude of magnetometry signals, implying that the finite-pulse-width effect should be taken into account for realizing accurate measurement of the frequency and amplitude of asynchronous AC magnetic fields.

AIP Advances•Jul 1, 2019•3 citations

High-dynamic-range magnetometry with a single electronic spin in diamond

Naufer Nusran, M. Ummal Momeen, M. V. Gurudev Dutt

Nature Nanotechnology•Dec 18, 2011•83 citations

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, Andrey Jarmola, Dmitry Budker +1 more

Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure $^{12}$C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ($> 500$) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches $T_1$ at a small number of applied DD pulses.

•Jan 1, 2018•10 citations
Dynamical decoupling sequences of multiple pulses offer filter functions for the time evolution of a qubit superposition state, and thus are indispensable tools for quantum sensing. The authors investigate the effects of sequences of finite-width pulses on ac magnetometry based on nitrogen-vacancy centers in isotopically controlled diamond. This experimental and theoretical study shows that finite pulse width alters the optimum acquisition time, and shows how to correct the resulting frequency shift, providing a guideline for accurate measurement of the frequency, linewidth, and amplitude of an ac field.
Quantum sensors based on the electron spin states of nitrogen vacancy centers in diamond have found wide application in magnetometry and nuclear spin magnetic resonance measurements. Previously, we have theoretically and experimentally investigated the effect of finite pulse width on quantum sensing for synchronous alternating-current (AC) magnetic fields to dynamical decoupling sequences [T. Ishikawa et al., Phys. Rev. Appl. 10, 054059 (2018)]. However, many biological and condensed-matter systems exhibit fluctuating AC fields over time, and thus, our model needs modifications because of additional non-ideal conditions in practical measurements. Here, we investigate the effects of finite pulse width of multiple-pulse decoupling sequences on quantum sensing for asynchronous AC magnetic fields. For this purpose, we use a spin ensemble of nitrogen vacancy centers in an isotopically purified diamond film. We reveal through experiments that the finite-width pulse causes shifts in AC magnetometry signals in a free-precession-time plot. In addition, our results indicate that the finite-width pulse affects the amplitude of magnetometry signals, implying that the finite-pulse-width effect should be taken into account for realizing accurate measurement of the frequency and amplitude of asynchronous AC magnetic fields.
Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12^{12}12C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (>500> 500>500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches T1T_1T1​ at a small number of applied DD pulses.