Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Continuous-Variable Measurement-Device-Independent Quantum Key Distribution with One-Time Shot-Noise Unit Calibration

Luyu Huang, Yichen Zhang, Song Yu

Published May 1, 2021• 14 citations
Publisher

Abstract

Imperfections in practical detectors, including limited detection efficiency, and inherent electronic noise, can seriously decrease the transmission distance of continuous-variable measurement-device-independent quantum key distribution systems. Owing to the difficulties inherent in realizing a high-efficiency fiber homodyne detector, challenges still exist in continuous-variable measurement-device-independent quantum key distribution system implementation. We offer an alternative approach in an attempt to solve these difficulties and improve the potential for system implementation. Here, a novel practical detector modeling method is utilized, which is combined with a one-time shot-noise-unit calibration method for the purpose of system realization. The new modeling method benefits greatly from taking advantage of one-time shot-noise-unit calibration methods, such as measuring electronic noise and shot noise directly to a novel shot-noise unit, so as to eliminate the statistical fluctuations found in previous methods; this makes the implementation of such systems simpler, and the calibration progress more accurate. We provide a simulation of the secret key rate versus distance with different parameters. In addition, the minimal detection efficiency required at each distance, as well as the contrast between the two methods, are also shown, so as to provide a reference in terms of system realization.

DOI
10.1088/0256-307x/38/4/040301

Related papers

One-Time Shot-Noise Unit Calibration Method for Continuous-Variable Quantum Key Distribution

Yichen Zhang, Yundi Huang, Ziyang Chen +3 more

The shot-noise unit in continuous-variable quantum key distribution plays an important and fundamental role in experimental implementation, as it is used as a normalization parameter that contributes to performing security analyses and distilling key information. However, the traditional calibration procedure and detector model cannot cover all system noise in practical applications, which results in loopholes and influences the practical security. What is more, the traditional procedure is also rather complicated and has difficulty in providing compatibility with automatic operating systems. In this paper, we propose a calibration model based on a proposed trusted detector model, which could naturally close the loopholes in practical applications. It can help to identify the shot-noise unit in only one step, which can not only effectively simplify the evaluation process but also reduce the statistical fluctuations, while two steps are needed in the traditional method. We prove its feasibility and derive a complete version of the corresponding entanglement-based model. A detailed security analysis against arbitrary collective attacks and numerous simulation results in both the asymptotic-limit regime and the finite-size regime are provided. A proof-of-principle experiment is implemented, and the results indicate that our one-time calibration model can be employed as a powerful alternative method for calibrating the shot-noise unit. Our method paves the way for the deployment of continuous-variable quantum key distribution with real-time calibration and automatic operation.

arXiv:1908.06230•Physical Review Applied•Feb 21, 2020•44 citations

Phase-Matching Continuous-Variable Measurement-Device-Independent Quantum Key Distribution

Peng Huang, Tao Wang, Duan Huang +1 more

Continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) allows remote parties to share information-theoretical secure keys while defending all the side-channel attacks on measurement devices. However, the secure transmission distance and the secret key rate are quite limited due to the high untrusted equivalent excess noise in the Gaussian modulation. More particularly, extremely high-efficiency homodyne detections are required for even non-zero secure transmission distances, which directly restrict its practical realization. Here, we propose a CV-MDI-QKD protocol by encoding the key information into matched discrete phases of two groups of coherent states, which decreases the required detection efficiency for ideally asymmetric cases, and makes it possible to practically achieve secure key distribution with current low-efficiency homodyne detections. Besides, a proof-of-principle experiment with a locally generated oscillator is implemented, which, for the first time, demonstrates the realizability of CV-MDI-QKD using all fiber-based devices. The discrete-modulated phase-matching method provides an alternative direction of an applicable quantum key distribution with practical security.

Symmetry•Mar 13, 2022•2 citations

Rigorous calibration of homodyne detection efficiency for continuous-variable quantum key distribution

Mi Zou, Yingqiu Mao, Teng‐Yun Chen

We propose a rigorous calibration method for homodyne detection efficiency, which combines all the factors that affect detection efficiency to calibrate together through the actual homodyne detection. With this method, the transmittance converted from electronic noise in the one-time calibration method of the shot noise can be attributed to the detection inefficiency. Thus, a trusted detection noise-free model for continuous-variable quantum key distribution (CV-QKD) can be established, which simplifies the calibration of shot noise while having the same performance as the trusted detection noise model. We demonstrate this calibration method with a balanced detector based on a transimpedance amplifier. Experimental results show that detection efficiency will be overestimated if the integration factor of the detector is overlooked. The overestimation of the detection efficiency leads to an underestimation of modulation variance and excess noise when the modulation variance is monitored by the balanced detector, which opens security loopholes. Our method may prove a necessary method in the calibration of detection efficiency for CV-QKD.

Optics Express•May 29, 2022•12 citations

Countermeasure for Negative Impact of a Practical Source in Continuous-Variable Measurement-Device-Independent Quantum Key Distribution

Luyu Huang, Xiangyu Wang, Ziyang Chen +3 more

Continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) can fundamentally defend all attacks on the measurement devices. Consequently, higher requirements are put forward for the source of a CV-MDI QKD system. However, the imperfections of the actual source brings practical security risks to the CV-MDI QKD system. Therefore, the characteristics of the realistic source must be controlled in real time to guarantee the practical security of the CV-MDI QKD system. Here we propose a countermeasure for negative impact introduced by the actual source in the CV-MDI QKD system based on the one-time-calibration method, not only eliminating the loophole induced from the relative intensity noise (RIN), which is part of the source noise, but also modeling the source noise thus improves the performance. In particular, three cases in terms of whether the preparation noise of the practical sources are defined or not, where only one of the users or both of the two users operate monitoring on their respective source outputs, are investigated. The simulation results show that the estimated secret key rate without our proposed scheme is about 10.7 times higher than the realistic rate at 18 km transmission distance when the variance of RIN is only 0.4. What is worse, the difference becomes greater and greater with the increase of the variance of RIN. Thus, our proposed scheme makes sense in further completing the practical security of the CV-MDI QKD system. In other words, our work enables the CV-MDI QKD system not only to resist all attacks against detectors, but also to close the vulnerability caused by the actual source, thus making the scheme closer to practical security.

arXiv:2306.15146•Physical Review Applied•Jan 6, 2023•6 citations

Discrete modulation continuous-variable measurement-device-independent quantum key distribution scheme based on realistic detector compensation

Xiaodong Wu, Duan Huang, Peng Huang +1 more

Discrete modulation continuous variable measurement device independent quantum key distribution scheme has good compatibility with efficient error correction codes, which leads to high reconciliation efficiency even at low signal-to-noise ratio. Besides, the implementation of this protocol is simpler than that of Gaussian modulation scheme. However, the quantum efficiency of homodyne detector commonly used in the experiment is only 0.6, which will seriously affect the practical application performance of discrete modulation continuous variable measurement device independent quantum key distribution scheme. To solve this problem, we propose a discrete modulation continuous variable measurement device independent quantum key distribution scheme based on realistic detector compensation. In our scheme, for the outputs of two quantum channels, each adopts a phase sensitive amplifier to compensate for the corresponding realistic homodyne detector. The simulation results show that the phase sensitive amplifier can well compensate for the quantum efficiency of the realistic detector and effectively improve the performance of the discrete modulation continuous variable measurement device independent quantum key distribution scheme with realistic detector in terms of secret key rate and secure transmission distance. The proposed protocol provides an effective method for promoting the practical development of the discrete modulation continuous variable measurement device independent quantum key distribution scheme.

Acta Physica Sinica•Jan 1, 2022•3 citations

An improved shot-noise unit calibration for continuous-variable quantum key distribution

Yichen Zhang, Yundi Huang, Ziyang Chen +2 more

An improved shot-noise unit calibration method for continuous-variable quantum key distribution is proposed with a modified trusted detector model, which could effectively simplify the calibration process and reduce the statistical fluctuation.

OSA Quantum 2.0 Conference•Jan 1, 2020•1 citation
Imperfections in practical detectors, including limited detection efficiency, and inherent electronic noise, can seriously decrease the transmission distance of continuous-variable measurement-device-independent quantum key distribution systems. Owing to the difficulties inherent in realizing a high-efficiency fiber homodyne detector, challenges still exist in continuous-variable measurement-device-independent quantum key distribution system implementation. We offer an alternative approach in an attempt to solve these difficulties and improve the potential for system implementation. Here, a novel practical detector modeling method is utilized, which is combined with a one-time shot-noise-unit calibration method for the purpose of system realization. The new modeling method benefits greatly from taking advantage of one-time shot-noise-unit calibration methods, such as measuring electronic noise and shot noise directly to a novel shot-noise unit, so as to eliminate the statistical fluctuations found in previous methods; this makes the implementation of such systems simpler, and the calibration progress more accurate. We provide a simulation of the secret key rate versus distance with different parameters. In addition, the minimal detection efficiency required at each distance, as well as the contrast between the two methods, are also shown, so as to provide a reference in terms of system realization.
The shot-noise unit in continuous-variable quantum key distribution plays an important and fundamental role in experimental implementation, as it is used as a normalization parameter that contributes to performing security analyses and distilling key information. However, the traditional calibration procedure and detector model cannot cover all system noise in practical applications, which results in loopholes and influences the practical security. What is more, the traditional procedure is also rather complicated and has difficulty in providing compatibility with automatic operating systems. In this paper, we propose a calibration model based on a proposed trusted detector model, which could naturally close the loopholes in practical applications. It can help to identify the shot-noise unit in only one step, which can not only effectively simplify the evaluation process but also reduce the statistical fluctuations, while two steps are needed in the traditional method. We prove its feasibility and derive a complete version of the corresponding entanglement-based model. A detailed security analysis against arbitrary collective attacks and numerous simulation results in both the asymptotic-limit regime and the finite-size regime are provided. A proof-of-principle experiment is implemented, and the results indicate that our one-time calibration model can be employed as a powerful alternative method for calibrating the shot-noise unit. Our method paves the way for the deployment of continuous-variable quantum key distribution with real-time calibration and automatic operation.
Continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) allows remote parties to share information-theoretical secure keys while defending all the side-channel attacks on measurement devices. However, the secure transmission distance and the secret key rate are quite limited due to the high untrusted equivalent excess noise in the Gaussian modulation. More particularly, extremely high-efficiency homodyne detections are required for even non-zero secure transmission distances, which directly restrict its practical realization. Here, we propose a CV-MDI-QKD protocol by encoding the key information into matched discrete phases of two groups of coherent states, which decreases the required detection efficiency for ideally asymmetric cases, and makes it possible to practically achieve secure key distribution with current low-efficiency homodyne detections. Besides, a proof-of-principle experiment with a locally generated oscillator is implemented, which, for the first time, demonstrates the realizability of CV-MDI-QKD using all fiber-based devices. The discrete-modulated phase-matching method provides an alternative direction of an applicable quantum key distribution with practical security.
We propose a rigorous calibration method for homodyne detection efficiency, which combines all the factors that affect detection efficiency to calibrate together through the actual homodyne detection. With this method, the transmittance converted from electronic noise in the one-time calibration method of the shot noise can be attributed to the detection inefficiency. Thus, a trusted detection noise-free model for continuous-variable quantum key distribution (CV-QKD) can be established, which simplifies the calibration of shot noise while having the same performance as the trusted detection noise model. We demonstrate this calibration method with a balanced detector based on a transimpedance amplifier. Experimental results show that detection efficiency will be overestimated if the integration factor of the detector is overlooked. The overestimation of the detection efficiency leads to an underestimation of modulation variance and excess noise when the modulation variance is monitored by the balanced detector, which opens security loopholes. Our method may prove a necessary method in the calibration of detection efficiency for CV-QKD.
Continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) can fundamentally defend all attacks on the measurement devices. Consequently, higher requirements are put forward for the source of a CV-MDI QKD system. However, the imperfections of the actual source brings practical security risks to the CV-MDI QKD system. Therefore, the characteristics of the realistic source must be controlled in real time to guarantee the practical security of the CV-MDI QKD system. Here we propose a countermeasure for negative impact introduced by the actual source in the CV-MDI QKD system based on the one-time-calibration method, not only eliminating the loophole induced from the relative intensity noise (RIN), which is part of the source noise, but also modeling the source noise thus improves the performance. In particular, three cases in terms of whether the preparation noise of the practical sources are defined or not, where only one of the users or both of the two users operate monitoring on their respective source outputs, are investigated. The simulation results show that the estimated secret key rate without our proposed scheme is about 10.7 times higher than the realistic rate at 18 km transmission distance when the variance of RIN is only 0.4. What is worse, the difference becomes greater and greater with the increase of the variance of RIN. Thus, our proposed scheme makes sense in further completing the practical security of the CV-MDI QKD system. In other words, our work enables the CV-MDI QKD system not only to resist all attacks against detectors, but also to close the vulnerability caused by the actual source, thus making the scheme closer to practical security.
Discrete modulation continuous variable measurement device independent quantum key distribution scheme has good compatibility with efficient error correction codes, which leads to high reconciliation efficiency even at low signal-to-noise ratio. Besides, the implementation of this protocol is simpler than that of Gaussian modulation scheme. However, the quantum efficiency of homodyne detector commonly used in the experiment is only 0.6, which will seriously affect the practical application performance of discrete modulation continuous variable measurement device independent quantum key distribution scheme. To solve this problem, we propose a discrete modulation continuous variable measurement device independent quantum key distribution scheme based on realistic detector compensation. In our scheme, for the outputs of two quantum channels, each adopts a phase sensitive amplifier to compensate for the corresponding realistic homodyne detector. The simulation results show that the phase sensitive amplifier can well compensate for the quantum efficiency of the realistic detector and effectively improve the performance of the discrete modulation continuous variable measurement device independent quantum key distribution scheme with realistic detector in terms of secret key rate and secure transmission distance. The proposed protocol provides an effective method for promoting the practical development of the discrete modulation continuous variable measurement device independent quantum key distribution scheme.