Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser Cooling and Slowing of Rubidium.

S. Padua

Published Jan 1, 1993• 0 citations
OpenAlex

Related papers

Laser Cooling and Magnetic Laser Cooling of Rubidium.

B. Sheehy

•Jan 1, 1990•0 citations

Sub-Doppler Laser Cooling of Rubidium

Song-Quan Shang

•Jan 1, 1991•0 citations

High resolution laser spectroscopy and laser cooling of rubidium vapour

Shrabana Chakrabarti

•Jan 1, 2016•0 citations

Laser cooling and compression of an atomic rubidium beam

G. Offermans

•Jan 1, 2015•0 citations

Novel Schemes for Sub-Doppler Laser Cooling of Rubidium.

Rajeev Gupta

•Jan 1, 1993•0 citations

Laser cooling and trapping of rubidium

Christopher D. Wallace, Timothy T. Grove, T. Dinneen +2 more

We have laser cooled an atomic beam of rubidium with diode lasers and have used these slow atoms to load a magneto-optical trap. The cooling is performed with the frequency-chirp method,1,2 in which the laser's frequency is ramped linearly (by the injection currant) to maintain resonance with the decelerating atoms. Two synchronously chirped lasers are required to prevent optical hyperfine pumping of the ground state. The chirp typically covers 500 MHz in 10 ms. At the end of each ramp, the resulting velocity distribution is measured with a pulsed probe laser. By varying the end point of the chirp, we are able to obtain slow atoms with average velocities ranging from 200 to −50 m/s. The widths of the velocity distributions are measured to be approximately 40 m/s. This relatively large width results from the inherent linewidth (~30 MHz) of the free-running diode lasers used for both cooling and probing.

Quantum Electronics and Laser Science Conference•May 12, 1991•0 citations
We have laser cooled an atomic beam of rubidium with diode lasers and have used these slow atoms to load a magneto-optical trap. The cooling is performed with the frequency-chirp method,1,2 in which the laser's frequency is ramped linearly (by the injection currant) to maintain resonance with the decelerating atoms. Two synchronously chirped lasers are required to prevent optical hyperfine pumping of the ground state. The chirp typically covers 500 MHz in 10 ms. At the end of each ramp, the resulting velocity distribution is measured with a pulsed probe laser. By varying the end point of the chirp, we are able to obtain slow atoms with average velocities ranging from 200 to −50 m/s. The widths of the velocity distributions are measured to be approximately 40 m/s. This relatively large width results from the inherent linewidth (~30 MHz) of the free-running diode lasers used for both cooling and probing.