Lecture notes in electrical engineering

The Electronic System of 87Rb CPT Maser Atomic Clock

Wenyu Zhao, Xin Wang, Xiaofeng Li, Jie Liu, Kan Zhao, Shougang Zhang

Published May 4, 2013• 0 citations
Publisher
DOI
10.1007/978-3-642-37407-4_28

Related papers

Comparison of field shifts in an atomic clock based on the effect of coherent population trapping in 87Rb atoms under modulation of laser pump current at frequencies of 3.4 and 6.8 GHz

S M Ignatovich, Mikhail N Skvortsov, I. S. Mesenzova +4 more

Experimental parameters of the resonance of coherent population trapping (CTP) on D1 line in 87Rb and light shifts are compared under modulation of the laser pump current at frequencies of 3.4 and 6.8 GHz. Reproducibility of the parameters of a laser with a vertical cavity needed for long-term stability of an atomic clock is considered. The instabilities of atomic CPT-clock obtained for 1 s are 1.2 × 10−11 and 3 × 10−12 for frequencies of 3.4 GHz and 6.8 GHz, respectively.

Quantum Electronics•Mar 30, 2022•1 citation

In A DIODE LASER PUMPED 87Rb ATOMIC CLOCK

Minoru Hashimoto, Motoichi Ohtsu, Hiroyuki Furuta

•Jan 1, 1987•0 citations

A polarization converting device for an interfering enhanced CPT atomic clock

Kewei Wang, Yuan Tian, Yi Yin +2 more

With interfering enhanced coherent population trapping (CPT) signals, a CPT atomic clock with improved frequency stability performance can be realized. We explore an optical device that converts single-polarized bichromatic light to left and right circularly polarized superposed bichromatic light to generate interfering enhanced CPT resonance with atoms. We have experimentally studied a tabletop CPT atomic clock apparatus with a microfabricated 87Rb atomic chip-scale cell, and the study results show that it is promising to realize a compact CPT atomic clock, even a chip-scale CPT atomic clock through microfabrication, with improved frequency stability performance.

Review of Scientific Instruments•Nov 1, 2017•5 citations

Novel Scheme for Chip-Scale CPT Atomic Clock

Yi Zhang, Sihong Gu

Lecture notes in electrical engineering•May 4, 2013•1 citation

Active Suppression of the Light Shift in an Atomic Clock Based on Coherent Population Trapping in 87Rb Vapor Using the Phase Jump Technique

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +4 more

The active suppression of light shift of the reference coherent population trapping (CPT) resonance in 87Rb vapor to improve the long-term stability of compact atomic clocks has been demonstrated experimentally. The approach is based on the phase jump technique used to synthesize an error signal, which is proportional to the light shift of the CPT resonance, from an optical transmission signal. The use of this error signal in an additional feedback loop allows one to stabilize the amplitude of a microwave signal for the phase modulation of laser radiation near a value at which the light shift of the CPT resonance is absent. This technique has made it possible to reduce the long-term instability of CPT atomic clocks in our experiments by a factor of 15 at an integration time of 10 000–20 000 s.

Письма в Журнал экспериментальной и теоретической физики•Apr 15, 2023•3 citations

A Chip Scale Lin⊥Lin Laser Scheme for CPT Atomic Clock

谭伯仲, 田原, 杨晶 +2 more

•Jan 1, 2013•0 citations
With interfering enhanced coherent population trapping (CPT) signals, a CPT atomic clock with improved frequency stability performance can be realized. We explore an optical device that converts single-polarized bichromatic light to left and right circularly polarized superposed bichromatic light to generate interfering enhanced CPT resonance with atoms. We have experimentally studied a tabletop CPT atomic clock apparatus with a microfabricated 87Rb atomic chip-scale cell, and the study results show that it is promising to realize a compact CPT atomic clock, even a chip-scale CPT atomic clock through microfabrication, with improved frequency stability performance.
The active suppression of light shift of the reference coherent population trapping (CPT) resonance in 87Rb vapor to improve the long-term stability of compact atomic clocks has been demonstrated experimentally. The approach is based on the phase jump technique used to synthesize an error signal, which is proportional to the light shift of the CPT resonance, from an optical transmission signal. The use of this error signal in an additional feedback loop allows one to stabilize the amplitude of a microwave signal for the phase modulation of laser radiation near a value at which the light shift of the CPT resonance is absent. This technique has made it possible to reduce the long-term instability of CPT atomic clocks in our experiments by a factor of 15 at an integration time of 10 000–20 000 s.