Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Journal of Chemical Physics

Bimodal velocity and size distributions of pulsed superfluid helium droplet beams

Rahul Pandey, Steven Tran, Jie Zhang, Yuzhong Yao, Wei Kong

Published Apr 1, 2021• 8 citations
Publisher

Abstract

We report detailed measurements of velocities and sizes of superfluid helium droplets produced from an Even-Lavie pulse valve at stagnation pressures of 20-60 atm and temperatures between 5.7 and 18.0 K. By doping neutral droplets with Rhodamine 6G cations produced from an electrospray ionization source and detecting the positively charged droplets at two different locations along the beam path, we determine the velocities of the different groups of droplets. By subjecting the doped droplet beam to a retardation field, size distributions can then be analyzed. We discover that at stagnation temperatures above 8.0 K, a single group of droplets is observed at both locations, but at 8.0 K and below, two different groups of droplets with different velocities are detectable. The slower group, considered from fragmentation of liquid helium, cannot be deterred by the retardation voltage at 9 kV, implying an exceedingly large size. The faster group, considered from condensation of gaseous helium, has a bimodal distribution when the stagnation temperatures are below 12.3 K at 20 and 40 atm, or 16.1 K at 60 atm. We also report similar size measurements using low energy electrons for impact ionization, and this latter method can be used for facile in situ characterization of pulsed droplet beams. The mechanism of the bimodal size distribution of the condensation group and the reason for the coexistence of both the condensation and fragmentation groups remain elusive.

DOI
10.1063/5.0047158

Related papers

Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams

Yunteng He, Jie Zhang, Yang Li +2 more

We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He2(+) and He4(+), which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl4 doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He)(n)C(+), (He)(n)Cl(+), and (He)(n)CCl(+). Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

Review of Scientific Instruments•Aug 1, 2015•14 citations

Rapidly pulsed helium droplet source

Dominik Pentlehner, Ricarda Riechers, Bernhard Dick +5 more

A pulsed valve connected to a closed-cycle cryostat was optimized for producing helium droplets. The pulsed droplet beam appeared with a bimodal size distribution. The leading part of the pulse consists of droplets suitable for doping with molecules. The average size of this part can be varied between 10(4) and 10(6) helium atoms, and the width of the distribution is smaller as compared to a continuous-flow droplet source. The system has been tested in a single pulse mode and at repetition rates of up to 500 Hz with almost constant intensity. The droplet density was found to be increased by more than an order of magnitude as compared to a continuous-flow droplet source.

Review of Scientific Instruments•Apr 1, 2009•86 citations

Sizes of large He droplets

Luis F. Gomez, Evgeny Loginov, Russell Sliter +1 more

Helium droplets spanning a wide size range, N(He) = 10(3)-10(10), were formed in a continuous-nozzle beam expansion at different nozzle temperatures and a constant stagnation pressure of 20 bars. The average sizes of the droplets have been obtained by attenuation of the droplet beam through collisions with argon and helium gases at room temperature. The results obtained are in good agreement with previous measurements in the size range N(He) = 10(5)-10(7). Moreover, the measurements give the average sizes in the previously uncharacterized range of very large droplets of 10(7)-10(10) atoms. The droplet sizes and beam flux increase rapidly at nozzle temperatures below 6 K, which is ascribed to the formation of droplets within the nozzle interior. The mass spectra of the droplet beam upon electron impact ionization have also been obtained. The spectra show a large increase in the intensity of the He(4) (+) signal upon increase of the droplet size, an effect which can be used as a secondary size standard in the droplet size range N(He) = 10(4)-10(9) atoms.

The Journal of Chemical Physics•Oct 18, 2011•180 citations

Sizes of pure and doped helium droplets from single shot x-ray imaging

Rico Mayro P. Tanyag, Camila Bacellar, Weiwu Pang +36 more

Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. This imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 109–1011 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.

The Journal of Chemical Physics•Jan 7, 2022•7 citations

Controlled growth of helium nanodroplets from a pulsed source

Shengfu Yang, Scott M. Brereton, Andrew M. Ellis

Factors affecting the size of liquid-helium droplets produced by a pulsed nozzle are described. The shape of the nozzle orifice is found to be important in allowing control of the size of the droplets. With an appropriate choice of nozzle geometry, the average droplet size is shown to be continuously variable over nearly two orders of magnitude by adjustment of the helium gas stagnation pressure and/or temperature. A scaling law similar to, but not identical with, that found for helium droplets produced by continuous supersonic expansion sources is found for the pulsed source. The pulsed nozzle described in this article has been used to make helium droplets ranging in size from a few thousand atoms up to nearly 105 helium atoms.

Review of Scientific Instruments•Oct 1, 2005•32 citations

Characterisation of a pulsed superfluid liquid helium droplet beam source

James Harries, Arisa Iguchi, Susumu Kuma

We have developed a new pulsed superfluid liquid helium droplet beam source for use as a target source for imaging and quantum optics experiment at a synchrotron or x-ray free-electron laser beamline. The characteristics of the source have been investigated using the titration method to estimate droplet sizes for different source temperatures and pressures.

•Jun 24, 2024•0 citations
We report detailed measurements of velocities and sizes of superfluid helium droplets produced from an Even-Lavie pulse valve at stagnation pressures of 20-60 atm and temperatures between 5.7 and 18.0 K. By doping neutral droplets with Rhodamine 6G cations produced from an electrospray ionization source and detecting the positively charged droplets at two different locations along the beam path, we determine the velocities of the different groups of droplets. By subjecting the doped droplet beam to a retardation field, size distributions can then be analyzed. We discover that at stagnation temperatures above 8.0 K, a single group of droplets is observed at both locations, but at 8.0 K and below, two different groups of droplets with different velocities are detectable. The slower group, considered from fragmentation of liquid helium, cannot be deterred by the retardation voltage at 9 kV, implying an exceedingly large size. The faster group, considered from condensation of gaseous helium, has a bimodal distribution when the stagnation temperatures are below 12.3 K at 20 and 40 atm, or 16.1 K at 60 atm. We also report similar size measurements using low energy electrons for impact ionization, and this latter method can be used for facile in situ characterization of pulsed droplet beams. The mechanism of the bimodal size distribution of the condensation group and the reason for the coexistence of both the condensation and fragmentation groups remain elusive.
We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He2(+) and He4(+), which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl4 doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He)(n)C(+), (He)(n)Cl(+), and (He)(n)CCl(+). Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.
A pulsed valve connected to a closed-cycle cryostat was optimized for producing helium droplets. The pulsed droplet beam appeared with a bimodal size distribution. The leading part of the pulse consists of droplets suitable for doping with molecules. The average size of this part can be varied between 10(4) and 10(6) helium atoms, and the width of the distribution is smaller as compared to a continuous-flow droplet source. The system has been tested in a single pulse mode and at repetition rates of up to 500 Hz with almost constant intensity. The droplet density was found to be increased by more than an order of magnitude as compared to a continuous-flow droplet source.
Helium droplets spanning a wide size range, N(He) = 10(3)-10(10), were formed in a continuous-nozzle beam expansion at different nozzle temperatures and a constant stagnation pressure of 20 bars. The average sizes of the droplets have been obtained by attenuation of the droplet beam through collisions with argon and helium gases at room temperature. The results obtained are in good agreement with previous measurements in the size range N(He) = 10(5)-10(7). Moreover, the measurements give the average sizes in the previously uncharacterized range of very large droplets of 10(7)-10(10) atoms. The droplet sizes and beam flux increase rapidly at nozzle temperatures below 6 K, which is ascribed to the formation of droplets within the nozzle interior. The mass spectra of the droplet beam upon electron impact ionization have also been obtained. The spectra show a large increase in the intensity of the He(4) (+) signal upon increase of the droplet size, an effect which can be used as a secondary size standard in the droplet size range N(He) = 10(4)-10(9) atoms.
Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. This imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 109–1011 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.
Factors affecting the size of liquid-helium droplets produced by a pulsed nozzle are described. The shape of the nozzle orifice is found to be important in allowing control of the size of the droplets. With an appropriate choice of nozzle geometry, the average droplet size is shown to be continuously variable over nearly two orders of magnitude by adjustment of the helium gas stagnation pressure and/or temperature. A scaling law similar to, but not identical with, that found for helium droplets produced by continuous supersonic expansion sources is found for the pulsed source. The pulsed nozzle described in this article has been used to make helium droplets ranging in size from a few thousand atoms up to nearly 105 helium atoms.