Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Atom interferometric method for eliminating Doppler effects in precision measurements

Wilpers, Oates, Hollberg

Published Jan 1, 2004• 0 citations
OpenAlex

Related papers

Precision measurements with atom interferometry

Steven Chu, David S. Weiss, Brent C. Young

Quantum Electronics and Laser Science Conference•May 2, 1993•0 citations

Atom interferometric method for eliminating Doppler effects in precision measurements

G. Wilpers, Chris W. Oates, Leo W. Hollberg

Abstract: We present a method to reduce the residual Doppler effect by almost two orders of magnitude in our optical frequency standard. The approach combines atom interferometry and launching of microkelvin neutral atoms.

Conference on Lasers and Electro-Optics•May 16, 2004•0 citations

Precision Measurements with Atom Interferometers

David E. Pritchard

APS•Apr 1, 1997•0 citations

Doppler- and recoil-free laser excitation of Rydberg states via three-photon transitions

I. I. Ryabtsev, Ilya I. Beterov, Denis B. Tretyakov +2 more

Three-photon laser excitation of Rydberg states by three different laser beams can be arranged in a starlike geometry that simultaneously eliminates the recoil effect and Doppler broadening. Our analytical and numerical calculations for a particular laser excitation scheme $5{S}_{1/2}\ensuremath{\rightarrow}5{P}_{3/2}\ensuremath{\rightarrow}6{S}_{1/2}\ensuremath{\rightarrow}nP$ in Rb atoms have shown that, compared to the one- and two-photon laser excitation, this approach provides much narrower linewidth and longer coherence time for both cold atom samples and hot vapors, if the intermediate one-photon resonances of the three-photon transition are detuned by more than respective single-photon Doppler widths. This method can be used to improve fidelity of Rydberg quantum gates and precision of spectroscopic measurements in Rydberg atoms.

arXiv:1110.0576•Physical Review A•Nov 11, 2011•79 citations

Precisely mapping the magnetic field gradient in vacuum with an atom interferometer

Min-Kang Zhou, Zhong-Kun Hu, Xiao‐Chun Duan +3 more

The magnetic field gradient has been measured with an atom interferometer using the magnetic sublevels of $^{87}\mathrm{Rb}$ atoms. The Doppler-insensitive measurement effectively eliminates the contribution from gravity and background vibration noise, and the differential measurement also can reject some systematic errors. A resolution of $300$ pT/mm has been demonstrated with a $90$-s integration time and a spatial resolution of $1.4$ mm. The gradiometer was then used to measure the magnetic field gradient in an ultrahigh-vacuum environment. The technique will also be very useful to subtract the systematic error arising from the magnetic field inhomogeneity in precision atom-interferometry experiments, such as gravity measurement.

Physical Review A•Dec 10, 2010•61 citations

Precision atom interferometry

Brian Anderson, T. L. Gustavson, Arnaud Landragin +4 more

Journal of the Communications Research Laboratory•Dec 1, 1999•0 citations
Three-photon laser excitation of Rydberg states by three different laser beams can be arranged in a starlike geometry that simultaneously eliminates the recoil effect and Doppler broadening. Our analytical and numerical calculations for a particular laser excitation scheme $5{S}_{1/2}\ensuremath{\rightarrow}5{P}_{3/2}\ensuremath{\rightarrow}6{S}_{1/2}\ensuremath{\rightarrow}nP$ in Rb atoms have shown that, compared to the one- and two-photon laser excitation, this approach provides much narrower linewidth and longer coherence time for both cold atom samples and hot vapors, if the intermediate one-photon resonances of the three-photon transition are detuned by more than respective single-photon Doppler widths. This method can be used to improve fidelity of Rydberg quantum gates and precision of spectroscopic measurements in Rydberg atoms.
The magnetic field gradient has been measured with an atom interferometer using the magnetic sublevels of 87Rb^{87}\mathrm{Rb}87Rb atoms. The Doppler-insensitive measurement effectively eliminates the contribution from gravity and background vibration noise, and the differential measurement also can reject some systematic errors. A resolution of 300300300 pT/mm has been demonstrated with a 909090-s integration time and a spatial resolution of 1.41.41.4 mm. The gradiometer was then used to measure the magnetic field gradient in an ultrahigh-vacuum environment. The technique will also be very useful to subtract the systematic error arising from the magnetic field inhomogeneity in precision atom-interferometry experiments, such as gravity measurement.