Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Enhanced performance of an all-optical parity checker using a single Mach-Zehnder interferometer

Yow, Chai Chai, Williams, Penty, Ian H. White

Published Jan 1, 2003• 4 citations
OpenAlex

Related papers

Hermitian operator of a Mach–Zehnder interferometer combined with parity detection and its applications

Shuai Wang, Jiandong Zhang

Optics Communications•Sep 15, 2022•5 citations

Parity measurements versus dual-homodyne measurements in coherent-state Mach–Zehnder interferometry

Jeffrey H. Shapiro

Previous studies [J. Opt. Soc. Am. B27, A170 (2010)JOBPDE0740-322410.1364/JOSAB.27.00A170; J. Appl. Phys.114, 193102 (2013)JAPIAU0021-897910.1063/1.4829016] have asserted that a coherent-state Mach–Zehnder interferometer (MZI) with parity-based phase estimation can achieve superresolution at the shot-noise limit (SNL). We show that these studies have ignored the need for repeated measurements in order to achieve root-mean-square accuracy at the SNL. Consequently, their superresolution claims need major revision. For comparison, we present the performance of a coherent-state MZI that uses dual-homodyne detection and show that it can achieve SNL scaling in a single measurement, albeit without superresolution.

Journal of the Optical Society of America B•Jul 27, 2017•3 citations

Parity measurements in optical interferometry and tests of quantum mechanics

Adil Benmoussa

•Jan 1, 2005•0 citations

Phase Sensitivity Optimization For a Hybrid Mach‐Zehnder Interferometer With Internal Parametric Amplifiers and One Input in the Vacuum State

Karunesh Kumar Mishra, Stefan Ataman

In this work, we address the problem of phase sensitivity optimization for a hybrid interferometer. The device we consider is composed of a usual Mach–Zehnder interferometer (MZI), however with parametric amplifiers (PA) inserted in each of its arms. We consider a generic pure input having one port in the vacuum state, and the MZI is assumed to be unbalanced. We address this optimization problem for both detection schemes having access – or not – to an external phase reference. As applications, we discuss a number of input states showing a potential interest in quantum metrology and thoroughly evaluate their performance. We discuss both the QFI and phase sensitivity scaling in respect with the average number of PA photons. We show that the PA‐enhanced MZI can outperform both the usual Mach–Zehnder and also the standard SU(1,1) interferometer having the same input resources. We also address the effect of both internal and external losses on the performance of the hybrid interferometer.

Advanced Quantum Technologies•Oct 1, 2026•0 citations

Matter Neutrality Test Using a Mach-Zehnder Interferometer

C. Champenois, M Büchner, R. Delhuille +4 more

Lecture notes in physics•Jul 11, 2001•10 citations

Enhancement of phase sensitivity by the additional resource in a Mach-Zehnder interferometer

Mengmeng Luo, Yuetao Chen, Jun Liu +2 more

Physics Letters A•Nov 11, 2021•3 citations
Previous studies [J. Opt. Soc. Am. B27, A170 (2010)JOBPDE0740-322410.1364/JOSAB.27.00A170; J. Appl. Phys.114, 193102 (2013)JAPIAU0021-897910.1063/1.4829016] have asserted that a coherent-state Mach–Zehnder interferometer (MZI) with parity-based phase estimation can achieve superresolution at the shot-noise limit (SNL). We show that these studies have ignored the need for repeated measurements in order to achieve root-mean-square accuracy at the SNL. Consequently, their superresolution claims need major revision. For comparison, we present the performance of a coherent-state MZI that uses dual-homodyne detection and show that it can achieve SNL scaling in a single measurement, albeit without superresolution.
In this work, we address the problem of phase sensitivity optimization for a hybrid interferometer. The device we consider is composed of a usual Mach–Zehnder interferometer (MZI), however with parametric amplifiers (PA) inserted in each of its arms. We consider a generic pure input having one port in the vacuum state, and the MZI is assumed to be unbalanced. We address this optimization problem for both detection schemes having access – or not – to an external phase reference. As applications, we discuss a number of input states showing a potential interest in quantum metrology and thoroughly evaluate their performance. We discuss both the QFI and phase sensitivity scaling in respect with the average number of PA photons. We show that the PA‐enhanced MZI can outperform both the usual Mach–Zehnder and also the standard SU(1,1) interferometer having the same input resources. We also address the effect of both internal and external losses on the performance of the hybrid interferometer.