Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Enhanced performance of an all-optical parity checker using a single Mach-Zehnder interferometer

Yow, Chai Chai, Williams, Penty, Ian H. White

Published Jan 1, 2003• 0 citations
OpenAlex

Related papers

Hermitian operator of a Mach–Zehnder interferometer combined with parity detection and its applications

Shuai Wang, Jiandong Zhang

Optics Communications•Sep 15, 2022•5 citations

Parity measurements versus dual-homodyne measurements in coherent-state Mach–Zehnder interferometry

Jeffrey H. Shapiro

Previous studies [J. Opt. Soc. Am. B27, A170 (2010)JOBPDE0740-322410.1364/JOSAB.27.00A170; J. Appl. Phys.114, 193102 (2013)JAPIAU0021-897910.1063/1.4829016] have asserted that a coherent-state Mach–Zehnder interferometer (MZI) with parity-based phase estimation can achieve superresolution at the shot-noise limit (SNL). We show that these studies have ignored the need for repeated measurements in order to achieve root-mean-square accuracy at the SNL. Consequently, their superresolution claims need major revision. For comparison, we present the performance of a coherent-state MZI that uses dual-homodyne detection and show that it can achieve SNL scaling in a single measurement, albeit without superresolution.

Journal of the Optical Society of America B•Jul 25, 2017•3 citations

Parity measurements in optical interferometry and tests of quantum mechanics

Adil Benmoussa

•Jan 1, 2005•0 citations

Parity detection in Quantum Optical metrology

Aravind Chiruvelli, Hwang Lee

Bulletin of the American Physical Society•May 21, 2009•1 citation

Gain sensitivity of the Mach-Zehnder interferometer by photon subtraction strategy

Mikhail S. Podoshvedov, Sergey A. Podoshvedov

We study sensitivity of phase estimation of Mach-Zehnder (MZ) interferometer with original two-mode squeezed vacuum (TMSV) state. At the initial stage, the TMSV state is converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted by measurement by photon-number resolving (PNR) detector in auxiliary modes. New measurement-induced continuous variable (CV) states of a certain parity can already demonstrate gain sensitivity more than 20 dB in relation to the initial SMSV states at the output from the MZ interferometer and follow to Heisenberg scaling in the case of subtracting a large number of photons in the measuring channels for practical values of the SMSV squeezing 5 dB>. Using only one measurement-induced CV state of a certain parity together with the SMSV state shows an increase in sensitivity of no more than 11 dB. We show that the sensitivity of the phase estimation obtained by measuring the intensity difference of two measurement-induced CV states in two arms of the MZ interferometer can surpass quantum Cramer-Rao (QCR) boundary of the original two SMSV states just in the practical range of input squeezing 5 dB>. In general, the strategy with preliminary subtraction of photons from two SMSV enables greatly enhance the sensitivity of the MZ interferometer in the practical case of small values of squeezing.

arXiv:2405.16261•May 25, 2024•0 citations

Optimal non-Gaussian operations in difference-intensity detection and parity detection-based Mach-Zehnder interferometer

Manali Verma, Chandan Kumar, Karunesh Kumar Mishra +1 more

We investigate the benefits of probabilistic non-Gaussian operations in phase estimation using difference-intensity and parity detection-based Mach-Zehnder interferometers (MZI). We consider an experimentally implementable model to perform three different non-Gaussian operations, namely photon subtraction (PS), photon addition (PA), and photon catalysis (PC) on a single-mode squeezed vacuum (SSV) state. In difference-intensity detection-based MZI, two PC operation is found to be the most optimal, while for parity detection-based MZI, two PA operation emerges as the most optimal process. We have also provided the corresponding squeezing and transmissivity parameters at best performance, making our study relevant for experimentalists. Further, we have derived the general expression of moment-generating function, which shall be useful in exploring other detection schemes such as homodyne detection and quadratic homodyne detection.

arXiv:2312.10774•Dec 17, 2023•2 citations
Previous studies [J. Opt. Soc. Am. B27, A170 (2010)JOBPDE0740-322410.1364/JOSAB.27.00A170; J. Appl. Phys.114, 193102 (2013)JAPIAU0021-897910.1063/1.4829016] have asserted that a coherent-state Mach–Zehnder interferometer (MZI) with parity-based phase estimation can achieve superresolution at the shot-noise limit (SNL). We show that these studies have ignored the need for repeated measurements in order to achieve root-mean-square accuracy at the SNL. Consequently, their superresolution claims need major revision. For comparison, we present the performance of a coherent-state MZI that uses dual-homodyne detection and show that it can achieve SNL scaling in a single measurement, albeit without superresolution.
We study sensitivity of phase estimation of Mach-Zehnder (MZ) interferometer with original two-mode squeezed vacuum (TMSV) state. At the initial stage, the TMSV state is converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted by measurement by photon-number resolving (PNR) detector in auxiliary modes. New measurement-induced continuous variable (CV) states of a certain parity can already demonstrate gain sensitivity more than 20 dB in relation to the initial SMSV states at the output from the MZ interferometer and follow to Heisenberg scaling in the case of subtracting a large number of photons in the measuring channels for practical values of the SMSV squeezing 5 dB>. Using only one measurement-induced CV state of a certain parity together with the SMSV state shows an increase in sensitivity of no more than 11 dB. We show that the sensitivity of the phase estimation obtained by measuring the intensity difference of two measurement-induced CV states in two arms of the MZ interferometer can surpass quantum Cramer-Rao (QCR) boundary of the original two SMSV states just in the practical range of input squeezing 5 dB>. In general, the strategy with preliminary subtraction of photons from two SMSV enables greatly enhance the sensitivity of the MZ interferometer in the practical case of small values of squeezing.
We investigate the benefits of probabilistic non-Gaussian operations in phase estimation using difference-intensity and parity detection-based Mach-Zehnder interferometers (MZI). We consider an experimentally implementable model to perform three different non-Gaussian operations, namely photon subtraction (PS), photon addition (PA), and photon catalysis (PC) on a single-mode squeezed vacuum (SSV) state. In difference-intensity detection-based MZI, two PC operation is found to be the most optimal, while for parity detection-based MZI, two PA operation emerges as the most optimal process. We have also provided the corresponding squeezing and transmissivity parameters at best performance, making our study relevant for experimentalists. Further, we have derived the general expression of moment-generating function, which shall be useful in exploring other detection schemes such as homodyne detection and quadratic homodyne detection.