Acta Physica Sinica

Generation of femtosecond pulsed quadrature phase squeezed light

Hongyu Liu, Chen Li, Liu Ling, Ming Ying, Liu Kui, Junxiang Zhang, Gao Jiang-Rui

Published Jan 1, 2013• 4 citations
Publisher

Abstract

We demonstrate experimentally the short pulse amplitude squeezed light from a singly resonant synchronously pumped optical parametric oscillator (SPOPO). The SPOPO operates in the frequency degenerate case and below threshold, with using a periodically poled potassium titanyl phosphate crystal. The pump laser is the second harmonic of a ultrashort mode-locked femtosecond pulse at 850 nm. The reduction of quantum noise of 2.58 dB is obtained experimentally. The squeezing extent is deduced to be 4.48 dB.

DOI
10.7498/aps.62.164206

Related papers

Effect of group-velocity dispersion on the generation of multimode pulsed squeezed light in a synchronously pumped optical parametric oscillator

Valentin Averchenko, Danil Malyshev, K. S. Tikhonov

Parametric down-conversion in a nonlinear crystal is a widely employed technique for generating quadrature squeezed light with multiple modes, which finds applications in quantum metrology, quantum information and communication. Here we study the generation of temporally multimode femtosecond pulsed squeezed light in a synchronously pumped optical parametric oscillator (SPOPO) operating below the oscillation threshold, while considering the presence of non-compensated intracavity group-velocity dispersion. Based on the developed time-domain model of the system, we show that the dispersion results in mode-dependent detuning of the broadband supermodes of the pulsed parametric process from the cavity resonance due to temporal Gouy phase, as well as linear coupling between these supermodes. With perturbation theory up to the second order in the coupling coefficients between modes, we obtained a solution for the amplitudes of multiple supermodes given an arbitrary sub-threshold pump level. The dispersion affects the quantum state of the supermodes by influencing their squeezing level and the rotation of the squeezing ellipse. It also affects the entanglement among the supermodes, leading to reduced suppression of shot noise level as measured in the balanced homodyne detection scheme. Furthermore, our study highlights the potential of SPOPO with group-velocity dispersion as a testbench for experimental investigations of multimode effects in linearly evanescent coupled parametric oscillators.

arXiv:2407.18826•New Journal of Physics•Dec 1, 2024•6 citations

3 dB squeezing by single-pass parametric amplification in a periodically poled KTiOPO_4 crystal

Takuya Hirano, K. Kotani, T. Ishibashi +2 more

We present the experimental observation of pulsed squeezed light from a degenerate optical parametric amplifier pumped by a second harmonic of a continuous-wave mode-locked Nd:YVO4 laser. With a single pass through a 10 mm long periodically poled KTiOPO4 crystal, the classical parametric gain of 11 is observed. The measured noise reduction in the quiet quadrature is 3.2 dB below the shot-noise level.

Optics Letters•Jul 1, 2005•34 citations

Observation of Squeezed Light in the 2 μm Region

Georgia L. Mansell, T. McRae, P. A. Altin +5 more

We present the generation and detection of squeezed light in the 2 μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1 dB of squeezing and 10.5±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.

arXiv:1805.12128•Physical Review Letters•May 17, 2018•52 citations

Generation and detection of squeezed states via a synchronously pumped optical parametric oscillator

Edoardo Suerra, Samuele Altilia, Stefano Olivares +7 more

A synchronously pumped optical parametric oscillator (SPOPO) operating at 93 MHz is used to generate squeezed states at 1035 nm. The system features a counter-propagating beam at the same wavelength as the quantum state, which simultaneously actively stabilizes the cavity and, after transmission, acts as the local oscillator for homodyne detection. By deriving the local oscillator directly from the SPOPO cavity, the setup establishes an intrinsically excellent spatial mode overlap and high interference visibility, forming a distinctive self-referenced architecture. Two spatial light modulators enable precise spectral shaping of both the pump and the local oscillator in amplitude and phase, allowing investigation of the spectral properties of the generated states. The versatility of the setup further allows exploration of different SPOPO configurations, including regimes with varied finesse and escape efficiency. Representative measurements, including homodyne traces and squeezing levels as functions of pump power and local oscillator bandwidth, demonstrate the performance of the system. Theoretical simulations based on a multimode singular-value-decomposition model reproduce well the measured dependence of squeezing on pump power and LO bandwidth, confirming the accuracy of the description and the robustness of the setup. Measured squeezing levels up to − 3.3 dB are achieved, corresponding to − 5.7 dB at SPOPO output, evidencing the robustness and versatility of this platform for stable pulsed squeezed-light generation and advanced quantum optical applications.

arXiv:2510.26414•Applied Physics B•Feb 17, 2026•7 citations

飞秒压缩光相位抖动抑制

孙倩 Sun Qian, 刘宏波 Liu Hongbo, 张云豪 Zhang Yunhao +2 more

Objective As a crucial quantum light source, the squeezed state of light plays a pivotal role in advancing quantum information, quantum networks, quantum computing, and quantum-precision measurements. The emergence of optical frequency combs is of great significance in the field of precision measurements and offers a novel avenue for achieving high-precision and long-distance measurements. The optical frequency comb represents a new class of light sources characterized by periodic ultrashort pulses, resulting in a spectrum with equally spaced frequencies. Based on the special properties of the optical frequency comb, researchers applied it to the quantum field, obtaining the “quantum frequency comb,” which is a new quantum resource contributing to the development of the quantum field. The generation of a femtosecond squeezed state in an optical field is challenging because of the extended cavity and optical path of the resonator. Compared with continuous waves, femtosecond pulses are more sensitive to external noise, posing difficulties in achieving a stable squeezed state. This limitation hinders the practical application of femtosecond squeezed light in quantum information protocols. Thus, achieving a long-term stable femtosecond pulse-squeezed state of the light field is considered a fundamental requirement. Methods A titanium sapphire laser is used to generate pulsed light with a central wavelength of 850 nm, pulse width of 130 fs, and pulse repetition rate of 76 MHz. A femtosecond pulse-squeezed vacuum state of the light field is obtained without signal injection based on a synchronously pumped optical parametric oscillator below the threshold. Nevertheless, the primary hurdle is the effective suppression of noise through the implementation of phase-locking between the signal and local components. To address this, the relative phase between the pump and local field is locked to suppress the phase noise. A bismuth borate (BIBO) nonlinear crystal with a thickness of 2 mm is used to generate the second harmonic. The second harmonic light generated by the pump is interference-locked with the pump. The interference signal is segmented into two paths and subtracted using a half-wave plate and polarization beam splitter (PBS) to improve the signal-to-noise ratio. Finally, the error signal is directed toward the proportion integration differentiation (PID) controller, which drives the piezoelectric ceramic in the local field. This achieves effective phase synchronization between the local field and pump. This synchronization locks the experimental light path before the 50/50 beam splitter. By improving the relative phase stability of the beams, a long-term stable femtosecond pulse-squeezed vacuum state of light is achieved. The degree of phase drift of the squeezed light is measured and analyzed for both the locked and unlocked phase loops. Results and Discussions In the absence of locked phase loops, the measured squeezed vacuum noise fluctuates significantly owing to external factors. Long-term monitoring reveals a large left-right drift in the power spectrum line of the squeezed vacuum noise, with a phase jitter range of 0.507 rad (Fig. 2). After locking the relative phase between the local field and pump, the stability of the system improves. The stability of the noise power spectrum of the squeezed light is significantly enhanced compared with that of the unlocked situation (Fig. 6). Simultaneously, the left-right drift at the squeezed light in both cases is analyzed, and data points are extracted and plotted in a scatter plot. The standard deviation of the two sets of data reflects the degree of phase jitter. The analysis results show that the random phase jitter is suppressed by 68.05% during the experiment (Fig. 7). Finally, the noise signals in both cases are smoothed. Under long-term measurement, the long-term squeezing degree increases from 0.6 dB to 3.2 dB, effectively inhibiting random phase jitter and improving the quality and accuracy of squeeze test results (Fig. 8). Conclusions Based on a synchronously pumped optical parametric oscillator below the threshold, a femtosecond pulse-squeezed vacuum state of the light field is obtained without signal field injection. This study successfully achieves a long-term stable output of squeezed vacuum state of femtosecond pulse through a scheme of frequency multiplication of local light and interference locking of frequency multiplication light with the pump. The experimental results demonstrate the successful suppression of 68.05% of the stochastic phase jitter during the squeezing measurement process, leading to an increase in the squeezing degree from 0.6 dB to 3.2 dB. Thus, the stability of the system is significantly enhanced. This methodology addresses the challenges associated with femtosecond pulses, paving the way for advancements in quantum technology.

Chinese Journal of Lasers•Jan 1, 2024•3 citations

QUADRATURE PHASE-SQUEEZING OF PUMP FIELD REFLECTED FROM TRIPLY RESONANT QUASI-PHASE-MATCHED OPTICAL PARAMETRIC OSCILLATOR

Yongmin Li, Fan Qiao-yun, Kuanshou Zhang +3 more

A quasi- phase-matched optical parametric oscillator(QPM OPO)consisting of a periodically poled LiNbO3(PPLN) crystal is pumped by an all-solid state single frequency Nd:YVO4 laser. The triple resonance of the pump mode and two subharmonic modes with near- degenerate frequencies are experimentally demonstrated by means of precision temperature control of the crystal. The threshold pump power is only 1.2mW. The quadrature phase noise squeezing of the pump field reflected from the OPO up to 1.1dB is observed at the pump power of 2.8 times of the oscillation threshold. The numerically calculated result is in good agreement with the experimentally measured data.

Acta Physica Sinica•Jan 1, 2001•0 citations
We demonstrate experimentally the short pulse amplitude squeezed light from a singly resonant synchronously pumped optical parametric oscillator (SPOPO). The SPOPO operates in the frequency degenerate case and below threshold, with using a periodically poled potassium titanyl phosphate crystal. The pump laser is the second harmonic of a ultrashort mode-locked femtosecond pulse at 850 nm. The reduction of quantum noise of 2.58 dB is obtained experimentally. The squeezing extent is deduced to be 4.48 dB.
Parametric down-conversion in a nonlinear crystal is a widely employed technique for generating quadrature squeezed light with multiple modes, which finds applications in quantum metrology, quantum information and communication. Here we study the generation of temporally multimode femtosecond pulsed squeezed light in a synchronously pumped optical parametric oscillator (SPOPO) operating below the oscillation threshold, while considering the presence of non-compensated intracavity group-velocity dispersion. Based on the developed time-domain model of the system, we show that the dispersion results in mode-dependent detuning of the broadband supermodes of the pulsed parametric process from the cavity resonance due to temporal Gouy phase, as well as linear coupling between these supermodes. With perturbation theory up to the second order in the coupling coefficients between modes, we obtained a solution for the amplitudes of multiple supermodes given an arbitrary sub-threshold pump level. The dispersion affects the quantum state of the supermodes by influencing their squeezing level and the rotation of the squeezing ellipse. It also affects the entanglement among the supermodes, leading to reduced suppression of shot noise level as measured in the balanced homodyne detection scheme. Furthermore, our study highlights the potential of SPOPO with group-velocity dispersion as a testbench for experimental investigations of multimode effects in linearly evanescent coupled parametric oscillators.
We present the generation and detection of squeezed light in the 2 μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1 dB of squeezing and 10.5±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.
A synchronously pumped optical parametric oscillator (SPOPO) operating at 93 MHz is used to generate squeezed states at 1035 nm. The system features a counter-propagating beam at the same wavelength as the quantum state, which simultaneously actively stabilizes the cavity and, after transmission, acts as the local oscillator for homodyne detection. By deriving the local oscillator directly from the SPOPO cavity, the setup establishes an intrinsically excellent spatial mode overlap and high interference visibility, forming a distinctive self-referenced architecture. Two spatial light modulators enable precise spectral shaping of both the pump and the local oscillator in amplitude and phase, allowing investigation of the spectral properties of the generated states. The versatility of the setup further allows exploration of different SPOPO configurations, including regimes with varied finesse and escape efficiency. Representative measurements, including homodyne traces and squeezing levels as functions of pump power and local oscillator bandwidth, demonstrate the performance of the system. Theoretical simulations based on a multimode singular-value-decomposition model reproduce well the measured dependence of squeezing on pump power and LO bandwidth, confirming the accuracy of the description and the robustness of the setup. Measured squeezing levels up to − 3.3 dB are achieved, corresponding to − 5.7 dB at SPOPO output, evidencing the robustness and versatility of this platform for stable pulsed squeezed-light generation and advanced quantum optical applications.
Objective As a crucial quantum light source, the squeezed state of light plays a pivotal role in advancing quantum information, quantum networks, quantum computing, and quantum-precision measurements. The emergence of optical frequency combs is of great significance in the field of precision measurements and offers a novel avenue for achieving high-precision and long-distance measurements. The optical frequency comb represents a new class of light sources characterized by periodic ultrashort pulses, resulting in a spectrum with equally spaced frequencies. Based on the special properties of the optical frequency comb, researchers applied it to the quantum field, obtaining the “quantum frequency comb,” which is a new quantum resource contributing to the development of the quantum field. The generation of a femtosecond squeezed state in an optical field is challenging because of the extended cavity and optical path of the resonator. Compared with continuous waves, femtosecond pulses are more sensitive to external noise, posing difficulties in achieving a stable squeezed state. This limitation hinders the practical application of femtosecond squeezed light in quantum information protocols. Thus, achieving a long-term stable femtosecond pulse-squeezed state of the light field is considered a fundamental requirement. Methods A titanium sapphire laser is used to generate pulsed light with a central wavelength of 850 nm, pulse width of 130 fs, and pulse repetition rate of 76 MHz. A femtosecond pulse-squeezed vacuum state of the light field is obtained without signal injection based on a synchronously pumped optical parametric oscillator below the threshold. Nevertheless, the primary hurdle is the effective suppression of noise through the implementation of phase-locking between the signal and local components. To address this, the relative phase between the pump and local field is locked to suppress the phase noise. A bismuth borate (BIBO) nonlinear crystal with a thickness of 2 mm is used to generate the second harmonic. The second harmonic light generated by the pump is interference-locked with the pump. The interference signal is segmented into two paths and subtracted using a half-wave plate and polarization beam splitter (PBS) to improve the signal-to-noise ratio. Finally, the error signal is directed toward the proportion integration differentiation (PID) controller, which drives the piezoelectric ceramic in the local field. This achieves effective phase synchronization between the local field and pump. This synchronization locks the experimental light path before the 50/50 beam splitter. By improving the relative phase stability of the beams, a long-term stable femtosecond pulse-squeezed vacuum state of light is achieved. The degree of phase drift of the squeezed light is measured and analyzed for both the locked and unlocked phase loops. Results and Discussions In the absence of locked phase loops, the measured squeezed vacuum noise fluctuates significantly owing to external factors. Long-term monitoring reveals a large left-right drift in the power spectrum line of the squeezed vacuum noise, with a phase jitter range of 0.507 rad (Fig. 2). After locking the relative phase between the local field and pump, the stability of the system improves. The stability of the noise power spectrum of the squeezed light is significantly enhanced compared with that of the unlocked situation (Fig. 6). Simultaneously, the left-right drift at the squeezed light in both cases is analyzed, and data points are extracted and plotted in a scatter plot. The standard deviation of the two sets of data reflects the degree of phase jitter. The analysis results show that the random phase jitter is suppressed by 68.05% during the experiment (Fig. 7). Finally, the noise signals in both cases are smoothed. Under long-term measurement, the long-term squeezing degree increases from 0.6 dB to 3.2 dB, effectively inhibiting random phase jitter and improving the quality and accuracy of squeeze test results (Fig. 8). Conclusions Based on a synchronously pumped optical parametric oscillator below the threshold, a femtosecond pulse-squeezed vacuum state of the light field is obtained without signal field injection. This study successfully achieves a long-term stable output of squeezed vacuum state of femtosecond pulse through a scheme of frequency multiplication of local light and interference locking of frequency multiplication light with the pump. The experimental results demonstrate the successful suppression of 68.05% of the stochastic phase jitter during the squeezing measurement process, leading to an increase in the squeezing degree from 0.6 dB to 3.2 dB. Thus, the stability of the system is significantly enhanced. This methodology addresses the challenges associated with femtosecond pulses, paving the way for advancements in quantum technology.
A quasi- phase-matched optical parametric oscillator(QPM OPO)consisting of a periodically poled LiNbO3(PPLN) crystal is pumped by an all-solid state single frequency Nd:YVO4 laser. The triple resonance of the pump mode and two subharmonic modes with near- degenerate frequencies are experimentally demonstrated by means of precision temperature control of the crystal. The threshold pump power is only 1.2mW. The quadrature phase noise squeezing of the pump field reflected from the OPO up to 1.1dB is observed at the pump power of 2.8 times of the oscillation threshold. The numerically calculated result is in good agreement with the experimentally measured data.