Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Differential compressive correlated imaging

Bai Xu, Yongqiang Li, Shengmei Zhao

Published Jan 1, 2013• 16 citations
Publisher

Abstract

Correlated imaging offers great potentiality, with respect to standard imaging, to obtain the imaging of objects located in optically harsh or noisy environment. It can solve the problems which are difficult to solve by conventional imaging techniques. Recently, it has become one of the hot topics in quantum optics. In this paper, we propose a new scheme of correlated imaging with differential correlated imaging based on compressive sensing, named differential compressive correlated imaging. The new scheme takes advantage of the high signal-to-noise ratio of the differential correlated imaging and low-imaging sampling frequency of the compressed sensing technique. In the scheme, we utilize the intensity of the thermal light, which is in line with the Gaussian distribution, as the measurement matrix of compressive sensing. We extract the differential object information as the image object information which could be recovered via orthogonal matching pursuit algorithm with high quality. By numerical simulations, we verify the proposed scheme. Here, we select the two gray-scale images, such as double-slit and NUPT, as well as the two multi-grayscale images (Lena and Boats) as the object. We take sampling 350 times in differential compressive correlated imaging for measurement. The numerical simulation results show that for the above image objects, the average mean-square error (MSE) over 10 times for the differential compressive correlated imaging scheme is reduced by 97.7%, 93.9%, 92.5% and 71.4% respectively with respect to that of the differential correlated imaging scheme. Moreover, compared with the compressive ghost imaging, the MSE value of the same double-slit in CDGI, as well as Lena and Boats under the same conditions, is reduced by 50.4%, 72.9% and 66.8% separately, which indicates that the compressive differential correlated imaging scheme can greatly improve the signal-to-noise ratio of the imaging, and significantly reduce the imaging time.

DOI
10.7498/aps.62.044209

Related papers

Robust Entangled-Photon Ghost Imaging with Compressive Sensing

Jun Li, Wenyu Gao, Jiachuan Qian +3 more

This work experimentally demonstrates that the imaging quality of quantum ghost imaging (GI) with entangled photons can be significantly improved by properly handling the errors caused by the imperfection of optical devices. We also consider compressive GI to reduce the number of measurements and thereby the data acquisition time. The image reconstruction is formulated as a sparse total least square problem which is solved with an iterative algorithm. Our experiments show that, compared with existing methods, the new method can achieve a significant performance gain in terms of mean square error and peak signal⁻noise ratio.

Sensors•Jan 7, 2019•16 citations

Quantum differential ghost microscopy

Elena Losero, Ivano Ruo Berchera, Alice Meda +3 more

Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol stemming from the differential ghost imaging, a scheme elaborated so far in the limit of bright thermal light, particularly suitable in the relevant case of faint or sparse objects. The extension toward the quantum regime represents an important step as quantum correlations allow low-brightness imaging, desirable for reducing the absorption dose. Furthermore, we optimize the protocol in terms of signal-to-noise ratio, to compensate for the detrimental effects of detection noise and losses. We perform the experiment using spontaneous parametric down conversion light in a microscope configuration. The image is reconstructed exploiting nonclassical intensity correlation in the low photon flux regime, rather than photon pairs detection coincidences. On the one side, we validate the theoretical model and on the other we show the applicability of this technique by imaging biological samples.

arXiv:1903.12630•Physical Review A•Dec 10, 2019•23 citations

Sampling number of image reconstruction arithmetic based on quantum correlated imaging

SU Fen

Quantum correlated imaging technology adopts single-point intensity detecting,huge information storage,slow imaging speed,so faster image reconstruction algorithm was required.The simulation of samples with image reconstructing algorithm was based on statistical arithmetic and compressed sensing respectively.The inputs of the compressed sensing algorithm are sparse images which are calculated with discrete cosine transform(DCT) and Gauss random matrices,reconstructing image with orthogonal matching pursuit(OMP).The result shows that the correlated imaging algorithm based on compressed sensing can lessen the number of measurements and save data space and speed.Therefore,the study of quantum correlated imaging image reconstruction algorithm has great significance for lessening the number of samples and improving imaging speed.

Chinese Journal of Quantum Electronics•Jan 1, 2015•0 citations

Complementary Normalized Compressive Ghost Imaging With Entangled Photons

Dawei Liu, Lifei Li, Hui Chen +5 more

We demonstrate a compressive normalized ghost imaging system with entangled photons employing complementary compressive imaging (CCI) technique. The quantum ghost image reconstruction was achieved with 19.53% sampling ratio of raster scanning and average 0.78 photons/pixel of each measurement. Using the special +1/-1 type sensing matrix and appropriate optimal algorithm, the photon utilization efficiency, and robustness of the imaging system is enhanced significantly. Our results reveal the great potential of CCI technique applied in quantum imaging and other quantum optics field such as quantum characterizing and quantum state tomography to use the information loaded in each photon with high efficiency.

arXiv:1703.04348•IEEE photonics journal•Mar 12, 2018•5 citations

COMPARATIVE ANALYSIS OF QUANTUM COMPRESSIVE IMAGING IN LOW PHOTON REGIME BY CONSIDERING PHOTON STATISTICS

Vamsi krishna Manthapuram

Compressive Imaging has been an extensively researched area inoptical imaging, object tracking,satellite applications,etc. There are many signalrecovery methods and comparative analyses of different algorithms in the presence of Gaussian noise. However, certain applications such as optical imaging at low photon intensityhavecounts of discrete events, which cannot be modelled using a Gaussian noise model. Instead, anoise model that incorporates photon statistics is needed. Researchers haveworkedon the Poisson noise modeland a different compressive sensing reconstruction was found.In this thesis, weconsidered a more general scenario of Compressive Imaging using non-classical photon states as light sources. We assumed that the Compressive Imaging system that consists of digital micromirror device (DMD), lenses, and detectors are perfect so that all noises comes from photons. Fock states and squeezed light thatpossess non-Poissonian statistics plays animportant role in Quantum Imaging. The image reconstruction was performed using several common compressive sensing signal reconstruction algorithms assuming Gaussian noise. This thesis showedthe behavior of the root mean square error (RMSE)with respectto the signal-to-noise ratio (SNR)for different photon statistics. In particular, the study showedthat all the noises perform similarly for the different algorithms. Based on the performance results for the different light sources, this researchcan be helpful in designing ageneralized Compressive Sensing model incorporating the photon statistics thatareapplicable in the field of Quantum Optics.

•Jun 22, 2016•0 citations

Entangled-photons compressive ghost imaging based on spatial correlation of sensing matrix

Dawei Liu, Lifei Li, Yixing Geng +5 more

Using the entangled photons generated by the spontaneous parametric down conversion as a light source, we demonstrate the first quantum ghost imaging system with a modified compressive sensing technique based on the spatial correlation of sensing matrix (SCCS). The ghost image is achieved at 16.27% sampling ratio of raster scanning and 0.65 photons/pixel at each measurement on average. Our results show that image quality and photon-utilization efficiency are remarkably enhanced in comparison with the traditional compressive imaging technique, due to the sensing matrix and noise-free measurement vector rebuilt by SCCS technique. It suggests the great potential of SCCS technique applied in quantum imaging and other quantum optics fields, such as quantum charactering and quantum state tomography to use the information loaded in each photon with high efficiency.

Optical Engineering•Dec 23, 2017•5 citations
Correlated imaging offers great potentiality, with respect to standard imaging, to obtain the imaging of objects located in optically harsh or noisy environment. It can solve the problems which are difficult to solve by conventional imaging techniques. Recently, it has become one of the hot topics in quantum optics. In this paper, we propose a new scheme of correlated imaging with differential correlated imaging based on compressive sensing, named differential compressive correlated imaging. The new scheme takes advantage of the high signal-to-noise ratio of the differential correlated imaging and low-imaging sampling frequency of the compressed sensing technique. In the scheme, we utilize the intensity of the thermal light, which is in line with the Gaussian distribution, as the measurement matrix of compressive sensing. We extract the differential object information as the image object information which could be recovered via orthogonal matching pursuit algorithm with high quality. By numerical simulations, we verify the proposed scheme. Here, we select the two gray-scale images, such as double-slit and NUPT, as well as the two multi-grayscale images (Lena and Boats) as the object. We take sampling 350 times in differential compressive correlated imaging for measurement. The numerical simulation results show that for the above image objects, the average mean-square error (MSE) over 10 times for the differential compressive correlated imaging scheme is reduced by 97.7%, 93.9%, 92.5% and 71.4% respectively with respect to that of the differential correlated imaging scheme. Moreover, compared with the compressive ghost imaging, the MSE value of the same double-slit in CDGI, as well as Lena and Boats under the same conditions, is reduced by 50.4%, 72.9% and 66.8% separately, which indicates that the compressive differential correlated imaging scheme can greatly improve the signal-to-noise ratio of the imaging, and significantly reduce the imaging time.
This work experimentally demonstrates that the imaging quality of quantum ghost imaging (GI) with entangled photons can be significantly improved by properly handling the errors caused by the imperfection of optical devices. We also consider compressive GI to reduce the number of measurements and thereby the data acquisition time. The image reconstruction is formulated as a sparse total least square problem which is solved with an iterative algorithm. Our experiments show that, compared with existing methods, the new method can achieve a significant performance gain in terms of mean square error and peak signal⁻noise ratio.
Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol stemming from the differential ghost imaging, a scheme elaborated so far in the limit of bright thermal light, particularly suitable in the relevant case of faint or sparse objects. The extension toward the quantum regime represents an important step as quantum correlations allow low-brightness imaging, desirable for reducing the absorption dose. Furthermore, we optimize the protocol in terms of signal-to-noise ratio, to compensate for the detrimental effects of detection noise and losses. We perform the experiment using spontaneous parametric down conversion light in a microscope configuration. The image is reconstructed exploiting nonclassical intensity correlation in the low photon flux regime, rather than photon pairs detection coincidences. On the one side, we validate the theoretical model and on the other we show the applicability of this technique by imaging biological samples.
Quantum correlated imaging technology adopts single-point intensity detecting,huge information storage,slow imaging speed,so faster image reconstruction algorithm was required.The simulation of samples with image reconstructing algorithm was based on statistical arithmetic and compressed sensing respectively.The inputs of the compressed sensing algorithm are sparse images which are calculated with discrete cosine transform(DCT) and Gauss random matrices,reconstructing image with orthogonal matching pursuit(OMP).The result shows that the correlated imaging algorithm based on compressed sensing can lessen the number of measurements and save data space and speed.Therefore,the study of quantum correlated imaging image reconstruction algorithm has great significance for lessening the number of samples and improving imaging speed.
We demonstrate a compressive normalized ghost imaging system with entangled photons employing complementary compressive imaging (CCI) technique. The quantum ghost image reconstruction was achieved with 19.53% sampling ratio of raster scanning and average 0.78 photons/pixel of each measurement. Using the special +1/-1 type sensing matrix and appropriate optimal algorithm, the photon utilization efficiency, and robustness of the imaging system is enhanced significantly. Our results reveal the great potential of CCI technique applied in quantum imaging and other quantum optics field such as quantum characterizing and quantum state tomography to use the information loaded in each photon with high efficiency.
Compressive Imaging has been an extensively researched area inoptical imaging, object tracking,satellite applications,etc. There are many signalrecovery methods and comparative analyses of different algorithms in the presence of Gaussian noise. However, certain applications such as optical imaging at low photon intensityhavecounts of discrete events, which cannot be modelled using a Gaussian noise model. Instead, anoise model that incorporates photon statistics is needed. Researchers haveworkedon the Poisson noise modeland a different compressive sensing reconstruction was found.In this thesis, weconsidered a more general scenario of Compressive Imaging using non-classical photon states as light sources. We assumed that the Compressive Imaging system that consists of digital micromirror device (DMD), lenses, and detectors are perfect so that all noises comes from photons. Fock states and squeezed light thatpossess non-Poissonian statistics plays animportant role in Quantum Imaging. The image reconstruction was performed using several common compressive sensing signal reconstruction algorithms assuming Gaussian noise. This thesis showedthe behavior of the root mean square error (RMSE)with respectto the signal-to-noise ratio (SNR)for different photon statistics. In particular, the study showedthat all the noises perform similarly for the different algorithms. Based on the performance results for the different light sources, this researchcan be helpful in designing ageneralized Compressive Sensing model incorporating the photon statistics thatareapplicable in the field of Quantum Optics.
Using the entangled photons generated by the spontaneous parametric down conversion as a light source, we demonstrate the first quantum ghost imaging system with a modified compressive sensing technique based on the spatial correlation of sensing matrix (SCCS). The ghost image is achieved at 16.27% sampling ratio of raster scanning and 0.65 photons/pixel at each measurement on average. Our results show that image quality and photon-utilization efficiency are remarkably enhanced in comparison with the traditional compressive imaging technique, due to the sensing matrix and noise-free measurement vector rebuilt by SCCS technique. It suggests the great potential of SCCS technique applied in quantum imaging and other quantum optics fields, such as quantum charactering and quantum state tomography to use the information loaded in each photon with high efficiency.