Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

OSA Quantum 2.0 Conference

Quantum Correlations with Human-Scale Oscillators in LIGO

Haocun Yu

Published Jan 1, 2020• 0 citations
Publisher

Abstract

By injecting squeezing in the Advanced LIGO, and exploiting quantum correlations from the radiation pressure induced coupling of light with the 40 kg mirrors, we measure their displacements with quantum noise 3dB below the SQL.
DOI
10.1364/quantum.2020.qw6a.6

Related papers

Quantum Enhancement of Advanced LIGO Detector Using Squeezed Vacuum States

M. Tse

The Advanced LIGO detector measures the distortion of spacetime from gravitational waves using Michelson interferometers. By injecting a squeezed vacuum state, we have demonstrated shot noise reduction, which enhanced the sensitivity of the LIGO detector. © 2019 The Author(s)

Conference on Lasers and Electro-Optics•May 5, 2019•0 citations

Quantum correlations between light and the kilogram-mass mirrors of LIGO

Hang Yu, Lee P. McCuller, M. Tse +97 more

Abstract The measurement of minuscule forces and displacements with ever greater precision is inhibited by the Heisenberg uncertainty principle, which imposes a limit to the precision with which the position of an object can be measured continuously, known as the standard quantum limit1–4. When light is used as the probe, the standard quantum limit arises from the balance between the uncertainties of the photon radiation pressure applied to the object and of the photon number in the photoelectric detection. The only way to surpass the standard quantum limit is by introducing correlations between the position/momentum uncertainty of the object and the photon number/phase uncertainty of the light that it reflects5. Here we confirm experimentally the theoretical prediction5 that this type of quantum correlation is naturally produced in the Laser Interferometer Gravitational-wave Observatory (LIGO). We characterize and compare noise spectra taken without squeezing and with squeezed vacuum states injected at varying quadrature angles. After subtracting classical noise, our measurements show that the quantum mechanical uncertainties in the phases of the 200-kilowatt laser beams and in the positions of the 40-kilogram mirrors of the Advanced LIGO detectors yield a joint quantum uncertainty that is a factor of 1.4 (3 decibels) below the standard quantum limit. We anticipate that the use of quantum correlations will improve not only the observation of gravitational waves, but also more broadly future quantum noise-limited measurements.

Civil War Book Review•Jan 1, 2020•62 citations

Quantum correlations between light and the kilogram-mass mirrors of LIGO

Haocun Yu, Lee P. McCuller, M. Tse +97 more

arXiv:2002.01519•Nature•Jul 1, 2020•197 citations

Frequency-Dependent Squeezing for Advanced LIGO

Lee P. McCuller, Chris Whittle, D. Ganapathy +13 more

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

arXiv:2003.13443•Physical Review Letters•Apr 28, 2020•173 citations

Observing and evading quantum back-action on a kilogram-scale oscillator

Begüm Kabagöz, Eric Oelker, Dhruva Ganapathy +203 more

Continuous quantum displacement measurements are fundamentally limited by a trade-off between readout imprecision and measurement back-action, constrained by the Heisenberg uncertainty principle. In the Laser Interferometric Gravitational-Wave Observatory (LIGO), these two quantum noise components dominate much of the observation band, making it an excellent testbed. We induce a sub-Hz-linewidth optomechanical mode by trapping the differential motion of the 40-kg mirrors in a band where radiation-pressure back-action dominates the motion. Engineering the quantum state entering the dark port creates correlations between imprecision and back-action that partially cancel their contributions, reducing observed motion near resonance by ~47%. A framework resolving the imprecision, back-action, and correlation terms identifies the origin of this suppression. These results demonstrate quantum back-action evasion and quantum reservoir engineering in a macroscopic optomechanical system.

quant-pharXiv:2609.19317•Sep 18, 2026•0 citations

Quantum Enhancement of Advanced LIGO Detector Using Squeezed Vacuum States

M. Tse

Conference on Lasers and Electro-Optics•Jan 1, 2019•0 citations
Abstract The measurement of minuscule forces and displacements with ever greater precision is inhibited by the Heisenberg uncertainty principle, which imposes a limit to the precision with which the position of an object can be measured continuously, known as the standard quantum limit1–4. When light is used as the probe, the standard quantum limit arises from the balance between the uncertainties of the photon radiation pressure applied to the object and of the photon number in the photoelectric detection. The only way to surpass the standard quantum limit is by introducing correlations between the position/momentum uncertainty of the object and the photon number/phase uncertainty of the light that it reflects5. Here we confirm experimentally the theoretical prediction5 that this type of quantum correlation is naturally produced in the Laser Interferometer Gravitational-wave Observatory (LIGO). We characterize and compare noise spectra taken without squeezing and with squeezed vacuum states injected at varying quadrature angles. After subtracting classical noise, our measurements show that the quantum mechanical uncertainties in the phases of the 200-kilowatt laser beams and in the positions of the 40-kilogram mirrors of the Advanced LIGO detectors yield a joint quantum uncertainty that is a factor of 1.4 (3 decibels) below the standard quantum limit. We anticipate that the use of quantum correlations will improve not only the observation of gravitational waves, but also more broadly future quantum noise-limited measurements.
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
Continuous quantum displacement measurements are fundamentally limited by a trade-off between readout imprecision and measurement back-action, constrained by the Heisenberg uncertainty principle. In the Laser Interferometric Gravitational-Wave Observatory (LIGO), these two quantum noise components dominate much of the observation band, making it an excellent testbed. We induce a sub-Hz-linewidth optomechanical mode by trapping the differential motion of the 40-kg mirrors in a band where radiation-pressure back-action dominates the motion. Engineering the quantum state entering the dark port creates correlations between imprecision and back-action that partially cancel their contributions, reducing observed motion near resonance by ~47%. A framework resolving the imprecision, back-action, and correlation terms identifies the origin of this suppression. These results demonstrate quantum back-action evasion and quantum reservoir engineering in a macroscopic optomechanical system.