Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

STIN

Nuclear magnetic resonance gyroscope

David M. Pepper, H. T. M. Wang

Published Dec 1, 1982• 1 citation
OpenAlex

Abstract

A study of the physics of a nuclear magnetic resonance gyroscope is described. Experimental results in nuclear polarization and relaxation in 3He are obtained using an optical pumping apparatus and a high resolution rf spectroscopic technique. Polarization in the metastable states of the heavy noble gases (20, 21 Ne, 129, 132 Xe) was observed using a similar optical pumping apparatus. A sensitive detection method based on optical polarization of an excited state transition is developed and compared with the conventional method of monitoring optical transmission through the optical pumping cell. A new concept for the optical pumping of odd-mass-numbered heavy noble was isotopes to provide for ground-state nuclear polarization is discussed. Significant polarization in excited state neon was observed via collisional transfer from optically pumped helium in a cell filled with a mixture of helium and neon isotopes. The measured polarization was essentially independent of the isotopic composition. (Author)

Related papers

Record nuclear polarization in optically pumped 3He gas using a high power LNA laser

N. P. Bigelow, Christian Larat, Pierre-Jean Nacher +1 more

Optical pumping is an efficient method for creating nuclear polarization M in a gas of 3He. M is first achieved in the metastable 23S state and then transfered to the ground state. Polarized 3He has numerous applications: quantum fluids, precision magnetometry, nuclear targets, etc. Much progress in achieving high values of M has resulted from the development of efficient IR lasers capable of exciting the 23S–23P3He transition at 1.08 μm. Using a novel lamp pumped LNA laser delivering 5 W cw, we have achieved M >85% for samples in the torr pressure range. To measure M we have developed an accurate technique based on the change as a function of M of the ratio between σ and π polarized light absorbed from a weak; probe beam by the 23S metastable atoms. The probe was delivered by a single mode tunable diode pumped LNA laser that was frequency modulated by using an étalon mounted on a galvoplate. M was also measured by monitoring the circular polarization of the 668 nm line emitted by the dis charge. Experimental and theoretical results on the optimization of the pumping will be presented, and the laser systems will be discussed.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Production of Hyperpolarized 129Xe Using Spin Exchange Optical Pumping

Vladimir Vladimirovich Kavtanyuk, Wooyoung Kim, Yu Ando +3 more

We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.

Journal of the Korean Physical Society•Nov 1, 2018•1 citation

Light-induced Frequency Shift and Relaxation of Ground-State 3He via Metastability-Exchange Collisions

L. Y. Wu, H. Yan

Metastability-exchange collisions (MECs) lie at the heart of metastability-exchange optical pumping (MEOP) in 3He, enabling the transfer of polarization from the metastable state to the ground state, as well as the optical detection of nuclear magnetic resonance. Leveraging MECs, optically pumped 3He nuclear magnetometers have been developed since the earliest demonstrations of MEOP. However, it also induces an additional frequency shift and relaxation of the nuclear spin precession, thereby limiting the sensitivity of the magnetometer. In this work, we identify a new source of frequency shift and relaxation in the 3He nuclear spin, arising from the light shift. This effect arises from an MEC-mediated interaction between light and the nucleon spin. We develop a theoretical model to describe this light-induced effect and highlight its significance in low magnetic fields. This effect is experimentally demonstrated, and its dependence on various parameters -- including magnetic field strength, light intensity, and wavelength -- is investigated. Our result provides a better understanding of the frequency shift and relaxation of 3He spin precession under MEOP conditions. Moreover, our experiment reveals an MEC-mediated coupling between the 3He nuclear spin and light, which may indicate the feasibility of MEC-assisted optical manipulation of 3He nuclear spins at the quantum level, as proposed in several theoretical schemes.

quant-pharXiv:2511.01313•Nov 4, 2025

Comparative Measurement of Transverse Nuclear Magnetization of Polarized 129 Xe and 131 Xe by Spin-exch ange Optical Pumping

Yu. Ye Jin, Seong Ho Min, Han-Seb Moon

We analyze the transverse nuclear magnetizations of 129Xe and 131Xe in a vapor cell containing natural Xe, 87Rb, and buffer gases. The Xe atoms are polarized through spin-exchange optical pumping (SEOP) with Rb atoms under low-magnetic-field conditions. From the free-induction-decay (FID) signal, we measure the nuclear magnetization of the Xe atoms in the Xe-Rb vapor cell. Furthermore, we measure the dependence of the gyromagnetic ratio on the magnetization of 129Xe and 131Xe by examining the amplitude of the FID signal of each isotope, and we evaluate the relationship between the magnetic field gradient and transverse relaxation rate for both of the 129Xe and 131Xe isotopes.

Current Optics and Photonics•Dec 25, 2020•2 citations

Nuclear Spin Gyroscope Based on an Atomic Comagnetometer

Thomas W. Kornack, Rajat K. Ghosh, Michael V. Romalis

We describe a nuclear spin gyroscope based on an alkali-metal--noble-gas comagnetometer. Optically pumped alkali-metal vapor is used to polarize the noble-gas atoms and detect their gyroscopic precession. Spin precession due to magnetic fields as well as their gradients and transients can be cancelled in this arrangement. The sensitivity is enhanced by using a high-density alkali-metal vapor in a spin-exchange relaxation free regime. With a $\mathrm{K}\mathrm{\text{\ensuremath{-}}}^{3}\mathrm{He}$ comagnetometer we demonstrate rotation sensitivity of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}\text{ }\text{ }\mathrm{rad}\text{ }{\mathrm{s}}^{\ensuremath{-}1}\text{ }{\mathrm{Hz}}^{\ensuremath{-}1/2}$, equivalent to a magnetic field sensitivity of $2.5\text{ }\text{ }\mathrm{fT}/{\mathrm{Hz}}^{1/2}$. The rotation signal can be increased by a factor of 10 using $^{21}\mathrm{Ne}$ with a smaller magnetic moment. The comagnetometer is also a promising tool in searches for anomalous spin couplings beyond the standard model.

arXiv:physics/0505089•Physical Review Letters•Nov 29, 2005•566 citations

Parameter analysis for a nuclear magnetic resonance gyroscope based on 133 Cs– 129 Xe/ 131 Xe

Dawei Zhang, Zhengyi Xu, Min Zhou +1 more

We theoretically investigate several parameters for the nuclear magnetic resonance gyroscope based on 133 Cs– 129 Xe/ 131 Xe. For a cell containing a mixture of 133 Cs at saturated pressure, we investigate the optimal quenching gas (N 2 ) pressure and the corresponding pump laser intensity to achieve 30% 133 Cs polarization at the center of the cell when the static magnetic field B 0 is 5 μ T with different 129 Xe/ 131 Xe pressure. The effective field produced by spin-exchange polarized 129 Xe or 131 Xe sensed by 133 Cs can also be discussed in different 129 Xe/ 131 Xe pressure conditions. Furthermore, the relationship between the detected signal and the probe laser frequency is researched. We obtain the optimum probe laser detuning from the D2 ( 6 2 S 1 / 2 → 6 2 P 3 / 2 ) resonance with different 129 Xe/ 131 Xe pressure owing to the pressure broadening.

Chinese Physics B•Feb 1, 2017•13 citations
A study of the physics of a nuclear magnetic resonance gyroscope is described. Experimental results in nuclear polarization and relaxation in 3He are obtained using an optical pumping apparatus and a high resolution rf spectroscopic technique. Polarization in the metastable states of the heavy noble gases (20, 21 Ne, 129, 132 Xe) was observed using a similar optical pumping apparatus. A sensitive detection method based on optical polarization of an excited state transition is developed and compared with the conventional method of monitoring optical transmission through the optical pumping cell. A new concept for the optical pumping of odd-mass-numbered heavy noble was isotopes to provide for ground-state nuclear polarization is discussed. Significant polarization in excited state neon was observed via collisional transfer from optically pumped helium in a cell filled with a mixture of helium and neon isotopes. The measured polarization was essentially independent of the isotopic composition. (Author)
Optical pumping is an efficient method for creating nuclear polarization M in a gas of 3He. M is first achieved in the metastable 23S state and then transfered to the ground state. Polarized 3He has numerous applications: quantum fluids, precision magnetometry, nuclear targets, etc. Much progress in achieving high values of M has resulted from the development of efficient IR lasers capable of exciting the 23S–23P3He transition at 1.08 μm. Using a novel lamp pumped LNA laser delivering 5 W cw, we have achieved M >85% for samples in the torr pressure range. To measure M we have developed an accurate technique based on the change as a function of M of the ratio between σ and π polarized light absorbed from a weak; probe beam by the 23S metastable atoms. The probe was delivered by a single mode tunable diode pumped LNA laser that was frequency modulated by using an étalon mounted on a galvoplate. M was also measured by monitoring the circular polarization of the 668 nm line emitted by the dis charge. Experimental and theoretical results on the optimization of the pumping will be presented, and the laser systems will be discussed.
We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.
Metastability-exchange collisions (MECs) lie at the heart of metastability-exchange optical pumping (MEOP) in 3He, enabling the transfer of polarization from the metastable state to the ground state, as well as the optical detection of nuclear magnetic resonance. Leveraging MECs, optically pumped 3He nuclear magnetometers have been developed since the earliest demonstrations of MEOP. However, it also induces an additional frequency shift and relaxation of the nuclear spin precession, thereby limiting the sensitivity of the magnetometer. In this work, we identify a new source of frequency shift and relaxation in the 3He nuclear spin, arising from the light shift. This effect arises from an MEC-mediated interaction between light and the nucleon spin. We develop a theoretical model to describe this light-induced effect and highlight its significance in low magnetic fields. This effect is experimentally demonstrated, and its dependence on various parameters -- including magnetic field strength, light intensity, and wavelength -- is investigated. Our result provides a better understanding of the frequency shift and relaxation of 3He spin precession under MEOP conditions. Moreover, our experiment reveals an MEC-mediated coupling between the 3He nuclear spin and light, which may indicate the feasibility of MEC-assisted optical manipulation of 3He nuclear spins at the quantum level, as proposed in several theoretical schemes.
We analyze the transverse nuclear magnetizations of 129Xe and 131Xe in a vapor cell containing natural Xe, 87Rb, and buffer gases. The Xe atoms are polarized through spin-exchange optical pumping (SEOP) with Rb atoms under low-magnetic-field conditions. From the free-induction-decay (FID) signal, we measure the nuclear magnetization of the Xe atoms in the Xe-Rb vapor cell. Furthermore, we measure the dependence of the gyromagnetic ratio on the magnetization of 129Xe and 131Xe by examining the amplitude of the FID signal of each isotope, and we evaluate the relationship between the magnetic field gradient and transverse relaxation rate for both of the 129Xe and 131Xe isotopes.
We describe a nuclear spin gyroscope based on an alkali-metal--noble-gas comagnetometer. Optically pumped alkali-metal vapor is used to polarize the noble-gas atoms and detect their gyroscopic precession. Spin precession due to magnetic fields as well as their gradients and transients can be cancelled in this arrangement. The sensitivity is enhanced by using a high-density alkali-metal vapor in a spin-exchange relaxation free regime. With a $\mathrm{K}\mathrm{\text{\ensuremath{-}}}^{3}\mathrm{He}$ comagnetometer we demonstrate rotation sensitivity of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}\text{ }\text{ }\mathrm{rad}\text{ }{\mathrm{s}}^{\ensuremath{-}1}\text{ }{\mathrm{Hz}}^{\ensuremath{-}1/2}$, equivalent to a magnetic field sensitivity of 2.5  fT/Hz1/22.5\text{ }\text{ }\mathrm{fT}/{\mathrm{Hz}}^{1/2}2.5  fT/Hz1/2. The rotation signal can be increased by a factor of 10 using 21Ne^{21}\mathrm{Ne}21Ne with a smaller magnetic moment. The comagnetometer is also a promising tool in searches for anomalous spin couplings beyond the standard model.
We theoretically investigate several parameters for the nuclear magnetic resonance gyroscope based on 133 Cs– 129 Xe/ 131 Xe. For a cell containing a mixture of 133 Cs at saturated pressure, we investigate the optimal quenching gas (N 2 ) pressure and the corresponding pump laser intensity to achieve 30% 133 Cs polarization at the center of the cell when the static magnetic field B 0 is 5 μ T with different 129 Xe/ 131 Xe pressure. The effective field produced by spin-exchange polarized 129 Xe or 131 Xe sensed by 133 Cs can also be discussed in different 129 Xe/ 131 Xe pressure conditions. Furthermore, the relationship between the detected signal and the probe laser frequency is researched. We obtain the optimum probe laser detuning from the D2 ( 6 2 S 1 / 2 → 6 2 P 3 / 2 ) resonance with different 129 Xe/ 131 Xe pressure owing to the pressure broadening.