Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cold-atom clock based on a diffractive optic

Rachel Elvin, Gregory W. Hoth, Wright, M., Ben Lewis, J. P. McGilligan, Aidan S. Arnold, Paul F. Griffin, Erling Riis

Published Dec 18, 2019• 14 citations
OpenAlex

Abstract

Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects 10 7 87Rb atoms, which are subsequently cooled to 20 µK in optical molasses. We optically probe the microwave atomic ground-state splitting using lin┴lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only 0.5 mm, the measured short-term fractional frequency stability is 2 × 10 −11/√τ.

Related papers

Cold-atom clock based on a diffractive optic

R. Elvin, G. W. Hoth, M. Wright +5 more

Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects $10^7$ $^{87}$Rb atoms, which are subsequently cooled to $20\,μ$K in optical molasses. We optically probe the microwave atomic ground-state splitting using lin$\perp$lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only $0.5\,$mm, the measured short-term fractional frequency stability is $2 \times 10 ^{-11} /\sqrtτ$.

arXiv:1909.04361•Optics Express•Dec 5, 2019•51 citations

Towards a compact, optically interrogated, cold-atom microwave clock

Rachel Elvin, Michael W. Wright, Ben Lewis +6 more

Abstract A compact platform for cold atoms opens a range of exciting possibilities for portable, robust and accessible quantum sensors. In this work, we report on the development of a cold-atom microwave clock in a small package. Our work utilises the grating magneto-optical trap and high-contrast coherent population trapping in the lin ⊥ $\perp $ lin polarisation scheme. We optically probe the atomic ground-state splitting of cold 87Rb atoms using a Ramsey-like sequence whilst the atoms are in free-fall. We have measured a short-term fractional frequency stability of 5 × 10 − 11 / τ $5{\times}{10}^{-11}/\sqrt{\tau }$ with a projected quantum projection noise limit at the 10 − 13 / τ ${10}^{-13}/\sqrt{\tau }$ level.

Advanced Optical Technologies•Sep 7, 2019•7 citations

Progress of a compact microwave clock based on atoms cooled with a diffractive optic

Rachel Elvin, Gregory W. Hoth, Michael W. Wright +6 more

An atomic clock based on a compact source of cold atoms and coherent population trapping (CPT) is an encouraging goal for future low-volume atomic frequency references. Our experiment seeks to investigate the performance of such a system by applying CPT in a high-contrast lin⊥lin polarisation scheme to our 87Rb grating magneto optical trap (GMOT) apparatus. In this paper, we report on our progress of improving short- term stability of our cold-atom CPT apparatus. Our recent measurements have shown a short-term stability of 5 x 10-11/√τ, with the ability to average down for times τ>100s.

SPIE eBooks•Feb 25, 2020•0 citations

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

A cold-atom Ramsey clock with a low volume physics package

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

arXiv:2305.02944•Scientific Reports•Jan 9, 2024•20 citations

Towards a compact atomic clock based on coherent population trapping and the grating magneto-optical trap

Erling Riis, Gregory W. Hoth, Rachel Elvin +4 more

The combination of coherent population trapping (CPT) and laser cooled atoms is a promising platform for realizing the next generation of compact atomic frequency references. Towards this goal, we have developed an apparatus based on the grating magneto-optical trap (GMOT) and the high-contrast lin ⊥ lin CPT scheme in order to explore the performance that can be achieved. One important trade-off for cold-atom systems arises from the need to simultaneously maximize the number of cold atoms available for interrogation and the repetition rate of the system. This compromise can be mitigated by recapturing cold atoms from cycle to cycle. Here, we report a quantitative characterization of the cold atom number in the recapture regime for our system, which will enable us to optimize this trade-off. We also report recent measurements of the short-term frequency stability with a short-term Allan deviation of 3 × 10-11/τ up to an averaging time of τ = 10 s.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•4 citations
Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects 10 7 87Rb atoms, which are subsequently cooled to 20 µK in optical molasses. We optically probe the microwave atomic ground-state splitting using lin┴lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only 0.5 mm, the measured short-term fractional frequency stability is 2 × 10 −11/√τ.
Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects 10710^7107 87^{87}87Rb atoms, which are subsequently cooled to 20 μ20\,μ20μK in optical molasses. We optically probe the microwave atomic ground-state splitting using lin⊥\perp⊥lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only 0.5 0.5\,0.5mm, the measured short-term fractional frequency stability is 2×10−11/τ2 \times 10 ^{-11} /\sqrtτ2×10−11/τ​.
Abstract A compact platform for cold atoms opens a range of exciting possibilities for portable, robust and accessible quantum sensors. In this work, we report on the development of a cold-atom microwave clock in a small package. Our work utilises the grating magneto-optical trap and high-contrast coherent population trapping in the lin ⊥ $\perp $ lin polarisation scheme. We optically probe the atomic ground-state splitting of cold 87Rb atoms using a Ramsey-like sequence whilst the atoms are in free-fall. We have measured a short-term fractional frequency stability of 5 × 10 − 11 / τ 5×10−11/τ5{\times}{10}^{-11}/\sqrt{\tau }5×10−11/τ​ with a projected quantum projection noise limit at the 10 − 13 / τ 10−13/τ{10}^{-13}/\sqrt{\tau }10−13/τ​ level.
An atomic clock based on a compact source of cold atoms and coherent population trapping (CPT) is an encouraging goal for future low-volume atomic frequency references. Our experiment seeks to investigate the performance of such a system by applying CPT in a high-contrast lin⊥lin polarisation scheme to our 87Rb grating magneto optical trap (GMOT) apparatus. In this paper, we report on our progress of improving short- term stability of our cold-atom CPT apparatus. Our recent measurements have shown a short-term stability of 5 x 10-11/√τ, with the ability to average down for times τ>100s.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
The combination of coherent population trapping (CPT) and laser cooled atoms is a promising platform for realizing the next generation of compact atomic frequency references. Towards this goal, we have developed an apparatus based on the grating magneto-optical trap (GMOT) and the high-contrast lin ⊥ lin CPT scheme in order to explore the performance that can be achieved. One important trade-off for cold-atom systems arises from the need to simultaneously maximize the number of cold atoms available for interrogation and the repetition rate of the system. This compromise can be mitigated by recapturing cold atoms from cycle to cycle. Here, we report a quantitative characterization of the cold atom number in the recapture regime for our system, which will enable us to optimize this trade-off. We also report recent measurements of the short-term frequency stability with a short-term Allan deviation of 3 × 10-11/τ up to an averaging time of τ = 10 s.