Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

An objective lens for efficient fluorescence detection of single atoms

Alt, W

Published Aug 28, 2001• 42 citations
OpenAlex

Abstract

We present the design of a diffraction limited, long working distance monochromatic objective lens for efficient light collection. Consisting of four spherical lenses, it has a numerical aperture of 0.29, an effective focal length of 36 mm and a working distance of 36.5 mm. This inexpensive system allows us to detect 8*10^4 fluorescence photons per second from a single cesium atom stored in a magneto-optical trap.

Related papers

Long working distance objective lenses for single atom trapping and imaging

J. D. Pritchard, J. A. Isaacs, M. Saffman

We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm, respectively, that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.

arXiv:1605.09051•Review of Scientific Instruments•Jul 1, 2016•23 citations

Long working distance objective lenses for single atom trapping and imaging

Pritchard, J.D., Isaacs, J.A., Mark E. Saffman

We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm respectively that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.

•Jul 26, 2016•7 citations

Diffraction-limited optics for single-atom manipulation

Yvan R. P. Sortais, H. Marion, Charles Tuchendler +8 more

We present an optical system designed to capture and observe a single neutral atom in an optical dipole trap, created by focusing a laser beam using a large-numerical-aperture $(\mathrm{NA}=0.5)$ aspheric lens. We experimentally evaluate the performance of the optical system and show that it is diffraction limited over a broad spectral range $(\ensuremath{\sim}200\phantom{\rule{0.3em}{0ex}}\mathrm{nm})$ with a large transverse field $(\ifmmode\pm\else\textpm\fi{}25\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m})$. The optical tweezer created at the focal point of the lens is able to trap single atoms of $^{87}\mathrm{Rb}$ and to detect them individually with a large collection efficiency. We measure the oscillation frequency of the atom in the dipole trap and use this value as an independent determination of the waist of the optical tweezer. Finally, we produce with the same lens two dipole traps separated by $2.2\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m}$ and show that the imaging system can resolve the two atoms.

arXiv:quant-ph/0610071•Physical Review A•Jan 8, 2007•119 citations

Detection of a single lithium atom in a magneto-optical trap

Hyok Sang Han, Seokchan Yoon, D. Cho

We report fluorescence detection of a single 7 Li atom in a magneto-optical trap (MOT). We use a double MOT system, which allows us to control the loading rate of the second MOT by simply turning on or off the first MOT and to use a modest magnetic field gradient of 46 G/cm. A single atom is trapped for longer than 100 s. The fluorescence from the trapped atoms is imaged onto an electron-multiplying charge-coupled device with a unit magnification factor by a pair of aspheric lenses. The numerical aperture of the objective lens is 0.22 with a collecting efficiency of 1.3%. Accumulated fluorescence is extracted by integrating the signal over a region of interest of 500×350 μ m 2 . For a 200-ms exposure time, the fluorescence count from a single atom is 8.8×10 3 and the background count from scattered MOT beams is 6.8 × 10 4 . We actively stabilize the trap beam power to reduce the noise and the measured noise is two times the statistical noise. Overall signal-to-noise ratio of the single-atom detection is 37/√ Hz. We also describe a modification of the system that is adapted to an experimental configuration for quantum manipulation of single atoms in a 1D optical lattice.

Journal of the Korean Physical Society•Jun 1, 2015•4 citations

Trapping and detection of single rubidium atoms in an optical dipole trap using a long-focus objective lens

Ilya I. Beterov, Elena A. Yakshina, Denis B. Tretyakov +7 more

Abstract The trapping of single atoms in optical dipole traps is widely used in experiments on the implementation of quantum processors based on neutral atoms, and studying interatomic interactions. Typically, such experiments employ lenses with a large numerical aperture (NA > 0.5), highly sensitive EMCCD cameras, or photon counters. In this work, we demonstrate trapping and detection of single rubidium atoms using a long-focus objective lens with a numerical aperture NA = 0.172 and a FLir Tau CNV sCMOS camera.

Quantum Electronics•Jun 1, 2020•9 citations

High-resolution ex vacuo objective for cold atom experiments

Xiao Min Li, Feng Zhou, Ke Min +4 more

We present a versatile and cost-efficient objective with a five-lens configuration, which consists completely of commercial singlets. The home-built objective has a numerical aperture (NA) of 0.44 and a long working distance of 35.9 mm, making it suitable for ex vacuo utilization. A diffraction-limited resolution of 1.08 μm and a field of view of about 210 μm are achieved when a 780 nm light passes through a 5 mm thick vacuum window. Moreover, such a design can be well adapted to a broad range of laser wavelengths (560-1000 nm) and vacuum window thicknesses (0-6 mm) by simply modifying one lens spacing, while maintaining a NA of above 0.43. The characteristics of the objective are evaluated experimentally, which are in good agreement with the simulations. Also, the objective has been successfully used for single-atom trapping and detecting in experiments. We believe that it will find more applications in various cold atom experiments.

Applied Optics•Sep 6, 2018•17 citations
We present the design of a diffraction limited, long working distance monochromatic objective lens for efficient light collection. Consisting of four spherical lenses, it has a numerical aperture of 0.29, an effective focal length of 36 mm and a working distance of 36.5 mm. This inexpensive system allows us to detect 8*10^4 fluorescence photons per second from a single cesium atom stored in a magneto-optical trap.
We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm, respectively, that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.
We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm respectively that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.
We present an optical system designed to capture and observe a single neutral atom in an optical dipole trap, created by focusing a laser beam using a large-numerical-aperture (NA=0.5)(\mathrm{NA}=0.5)(NA=0.5) aspheric lens. We experimentally evaluate the performance of the optical system and show that it is diffraction limited over a broad spectral range $(\ensuremath{\sim}200\phantom{\rule{0.3em}{0ex}}\mathrm{nm})$ with a large transverse field $(\ifmmode\pm\else\textpm\fi{}25\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m})$. The optical tweezer created at the focal point of the lens is able to trap single atoms of 87Rb^{87}\mathrm{Rb}87Rb and to detect them individually with a large collection efficiency. We measure the oscillation frequency of the atom in the dipole trap and use this value as an independent determination of the waist of the optical tweezer. Finally, we produce with the same lens two dipole traps separated by $2.2\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m}$ and show that the imaging system can resolve the two atoms.
We report fluorescence detection of a single 7 Li atom in a magneto-optical trap (MOT). We use a double MOT system, which allows us to control the loading rate of the second MOT by simply turning on or off the first MOT and to use a modest magnetic field gradient of 46 G/cm. A single atom is trapped for longer than 100 s. The fluorescence from the trapped atoms is imaged onto an electron-multiplying charge-coupled device with a unit magnification factor by a pair of aspheric lenses. The numerical aperture of the objective lens is 0.22 with a collecting efficiency of 1.3%. Accumulated fluorescence is extracted by integrating the signal over a region of interest of 500×350 μ m 2 . For a 200-ms exposure time, the fluorescence count from a single atom is 8.8×10 3 and the background count from scattered MOT beams is 6.8 × 10 4 . We actively stabilize the trap beam power to reduce the noise and the measured noise is two times the statistical noise. Overall signal-to-noise ratio of the single-atom detection is 37/√ Hz. We also describe a modification of the system that is adapted to an experimental configuration for quantum manipulation of single atoms in a 1D optical lattice.
Abstract The trapping of single atoms in optical dipole traps is widely used in experiments on the implementation of quantum processors based on neutral atoms, and studying interatomic interactions. Typically, such experiments employ lenses with a large numerical aperture (NA > 0.5), highly sensitive EMCCD cameras, or photon counters. In this work, we demonstrate trapping and detection of single rubidium atoms using a long-focus objective lens with a numerical aperture NA = 0.172 and a FLir Tau CNV sCMOS camera.
We present a versatile and cost-efficient objective with a five-lens configuration, which consists completely of commercial singlets. The home-built objective has a numerical aperture (NA) of 0.44 and a long working distance of 35.9 mm, making it suitable for ex vacuo utilization. A diffraction-limited resolution of 1.08 μm and a field of view of about 210 μm are achieved when a 780 nm light passes through a 5 mm thick vacuum window. Moreover, such a design can be well adapted to a broad range of laser wavelengths (560-1000 nm) and vacuum window thicknesses (0-6 mm) by simply modifying one lens spacing, while maintaining a NA of above 0.43. The characteristics of the objective are evaluated experimentally, which are in good agreement with the simulations. Also, the objective has been successfully used for single-atom trapping and detecting in experiments. We believe that it will find more applications in various cold atom experiments.