Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Instruments and Experimental Techniques

Up-conversion of near-infrared emission frequency and the distribution of photocounts in a detector with parametric frequency conversion

V S Dugin, I. N. Matveev, S M Pshenichnikov, N. P. Sopina, A F Umnov

Published Dec 1, 1975• 0 citations
OpenAlex

Related papers

Photocount distribution from the coherent signal recorded by a detector with variable efficiency against the background of noise

Александр Сергеевич Мазманишвили

Radiophysics and Quantum Electronics•Jan 1, 2000•0 citations

Investigation of the statistical characteristics of spontaneous noise in parametric frequency converters

I. N. Matveev, S M Pshenichnikov, A F Umnov

An experimental investigation was made of the statistical characteristics of spontaneous parametric luminescence generated in the course of parametric frequency up-conversion. It was found that the laws governing the amplitude distribution and the distribution of photocounts of parametric luminescence were nearly of the Poisson type.

Soviet Journal of Quantum Electronics•Nov 30, 1980•0 citations

Photocount distribution for intensity-modulated laser emission

G. Ia. Umarov, As T Mirzaev, Kh. Kh. Khadzhimukhamedov

•Jan 1, 1977•0 citations

Statistics of photocounts in parametric frequency conversion

Yu A Il'inskiĭ, Vera M. Petnikova

The variance and average value of photocounts (counts of electrons emitted by the cathode of a photodetector) are calculated allowing for the existence of the following sources of noise in a frequency converter: fluctuations of the pump intensity, conversion of background radiation, thermal fluctuations of fields in the converter crystal, spontaneous generation of the difference frequency, and illumination of the photodetector with the pump radiation transmitted by filters. A function representing the distribution of photocounts is obtained for short time intervals allowing for fluctuations of the pumping intensity in the case of conversion of a random Gaussian signal.

Soviet Journal of Quantum Electronics•May 31, 1974•0 citations

Statistics of photocounts recorded by a detector with variable quantum efficiency

Александр Сергеевич Мазманишвили

Radiophysics and Quantum Electronics•Aug 1, 1998•0 citations

Towards Integrated on-Chip Liquid Sensing Based on Correlated Photons

Joschka Schöner, Chiara Lindner, Simon J. Herr +2 more

The emissions of two identical spontaneous parametric down-conversion (SPDC) sources pumped coherently, e.g. with the same beam (c.f. Fig. 1(a)), show interference in both, the signal and idler light. This phenomenon results from the indistinguishability of the photon pairs emitted by the identical sources [1]. If a medium between the two SPDC sources absorbs the idler light, the photon pairs from the first and second SPDC source become distinguishable and the interference contrast decreases for both, signal and idler light. By measuring the signal light spectrum in the visible or near-infrared (NIR) range and the corresponding interference contrast, we obtain the information about the idler light absorption of the analyte in the mid-infrared (MIR). Hereby, we enable spectroscopy in the MIR using a standard silicon detector, making detection easier and more efficient than using typical MIR detectors [2].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations
The variance and average value of photocounts (counts of electrons emitted by the cathode of a photodetector) are calculated allowing for the existence of the following sources of noise in a frequency converter: fluctuations of the pump intensity, conversion of background radiation, thermal fluctuations of fields in the converter crystal, spontaneous generation of the difference frequency, and illumination of the photodetector with the pump radiation transmitted by filters. A function representing the distribution of photocounts is obtained for short time intervals allowing for fluctuations of the pumping intensity in the case of conversion of a random Gaussian signal.
The emissions of two identical spontaneous parametric down-conversion (SPDC) sources pumped coherently, e.g. with the same beam (c.f. Fig. 1(a)), show interference in both, the signal and idler light. This phenomenon results from the indistinguishability of the photon pairs emitted by the identical sources [1]. If a medium between the two SPDC sources absorbs the idler light, the photon pairs from the first and second SPDC source become distinguishable and the interference contrast decreases for both, signal and idler light. By measuring the signal light spectrum in the visible or near-infrared (NIR) range and the corresponding interference contrast, we obtain the information about the idler light absorption of the analyte in the mid-infrared (MIR). Hereby, we enable spectroscopy in the MIR using a standard silicon detector, making detection easier and more efficient than using typical MIR detectors [2].