Third Harmonic Microwave Generation by Superconductors

Brian P. Wilfley

Published Jan 1, 1983• 0 citations
OpenAlex

Related papers

Microwave amplification with superconductors

A.S. Clorfeine

Proceedings of the IEEE•Jan 1, 1964•18 citations

Analysis and Simulation of the Effects of Distributed Nonlinearities in Microwave Superconducting Devices

Carlos Collado, Jordi Mateu, Joan M. O'Callaghan

This paper presents a comprehensive study of microwave nonlinearities in superconductors, with an emphasis on intermodulation distortion and third-harmonic generation. It contains the analysis of various resonant and nonresonant test devices and its validation using numerical simulations based on harmonic balance (HB). The HB simulations made on test devices show that the closed-form equations for intermodulation and third-harmonic generation are only valid at low power levels. The paper also contains examples of application of HB to illustrate that this technique is useful to simulate superconductive devices other than simple test devices, and that the validity of the simulations is not restricted to low drive power levels. Most of the analyses and simulations of this paper are based on electrical parameters that describe the nonlinearities in the superconducting material. These parameters are compatible with many existing models of microwave nonlinearities in superconductors. We discuss the particulars on how to relate these electrical parameters with one of the existing models that postulates that the nonlinear effects are due to a dependence of the penetration depth on the current density in the superconductor.

IEEE Transactions on Applied Superconductivity•Mar 1, 2005•62 citations

Superconducting Microwave Resonators

Charles Neill, A. Megrant, M. Lenander +17 more

Bulletin of the American Physical Society•Mar 1, 2012•0 citations

Third harmonic generation through shaped superconductors

T. Badri Narayana, M. Satyam

This paper describes a methodology of obtaining only third harmonic along with the fundamental using shaped superconductors. It also indicates how one can design a nonlinear superconducting resistor with the required current versus resistance variation.

Review of Scientific Instruments•Jan 1, 1995•3 citations

One-third (period three) harmonic generation in microwave-driven Josephson tunnel junctions

Jørn Bindslev Hansen, John L. Clarke, J. Mygind +2 more

One-third harmonic signals have been generated in the zero voltage state of a Josephson tunnel junction driven with a microwave current in the frequency range 8–20 GHz. The signal was as much as 50 dB above the noise level of the detector with a linewidth of less than 100 Hz. The junction parameters and microwave current were measured in situ in separate experiments. The subharmonic generation occurred for ranges of microwave current and frequency that were in reasonable agreement with the results of digital computer simulations.

Applied Physics Letters•Dec 22, 1986•3 citations

Microwave Superconductivity

Springer eBooks•Jan 1, 2001•25 citations
This paper presents a comprehensive study of microwave nonlinearities in superconductors, with an emphasis on intermodulation distortion and third-harmonic generation. It contains the analysis of various resonant and nonresonant test devices and its validation using numerical simulations based on harmonic balance (HB). The HB simulations made on test devices show that the closed-form equations for intermodulation and third-harmonic generation are only valid at low power levels. The paper also contains examples of application of HB to illustrate that this technique is useful to simulate superconductive devices other than simple test devices, and that the validity of the simulations is not restricted to low drive power levels. Most of the analyses and simulations of this paper are based on electrical parameters that describe the nonlinearities in the superconducting material. These parameters are compatible with many existing models of microwave nonlinearities in superconductors. We discuss the particulars on how to relate these electrical parameters with one of the existing models that postulates that the nonlinear effects are due to a dependence of the penetration depth on the current density in the superconductor.
One-third harmonic signals have been generated in the zero voltage state of a Josephson tunnel junction driven with a microwave current in the frequency range 8–20 GHz. The signal was as much as 50 dB above the noise level of the detector with a linewidth of less than 100 Hz. The junction parameters and microwave current were measured in situ in separate experiments. The subharmonic generation occurred for ranges of microwave current and frequency that were in reasonable agreement with the results of digital computer simulations.