Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Quantum thermometry based on a cavity-QED setup

Dong Xie, Feng-Xiao Sun, Chunling Xu

Published Jun 30, 2020• 10 citations
Publisher

Abstract

We present a quantum thermometry scheme based on a cavity-QED setup, which attains a sensitivity with Heisenberg scaling. A stream of identical two-level systems passes through a thermal bath to be tested. Each system partially thermalizes, carrying information on the temperature of the thermal bath, and it then interacts with a dissipative single-mode cavity. The Heisenberg scaling is attained from the initial coherence of each system. The systems cannot be fully thermalized by the thermal bath. The optimal interaction time between the system and the thermal bath is derived. Direct photon detection is proved to be an optimal measurement when there is no extra thermal bath in the cavity. In the case where there is an extra thermal bath in the cavity independent of the thermal bath to be tested, homodyne detection is the optimal measurement. Moreover, we show that direct photon detection obtains less information in the case where the extra thermal bath in the cavity is in thermal equilibrium with the thermal bath. However, the optimal measurement can utilize the information from the extra thermal bath to improve the estimation precision of the temperature.

DOI
10.1103/physreva.101.063844

Related papers

Two-qubit quantum probes for the temperature of an Ohmic environment

Francesca Gebbia, Claudia Benedetti, Fabio Benatti +3 more

We address a particular instance where open quantum systems may be used as quantum probes for an emergent property of a complex system, as the temperature of a thermal bath. The inherent fragility of the quantum probes against decoherence is the key feature making the overall scheme very sensitive. The specific setting examined here is that of quantum thermometry, which aims to exploit decoherence as a resource to estimate the temperature of a sample. We focus on temperature estimation for a bosonic bath at equilibrium in the Ohmic regime (ranging from sub-Ohmic to super-Ohmic), by using pairs of qubits in different initial states and interacting with different environments, consisting either of a single thermal bath or of two independent ones at the same temperature. Our scheme involves pure dephasing of the probes, thus avoiding energy exchange with the sample and the consequent perturbation of temperature itself. We discuss the role of correlations among the probes and the presence of a local versus a global bath. We show that entanglement improves thermometry at short times if the two qubits are embedded in a common bath, whereas if the interaction time is not constrained, then coherence rather than entanglement is the key resource in quantum thermometry.

arXiv:1912.02442•Physical Review A•Mar 17, 2020•65 citations

Nonequilibrium quantum thermometry with noncommutative system-bath couplings

Youssef Aiache, Abderrahim El Allati, İlkay Demir +1 more

Accurate temperature estimation in the quantum and cryogenic regimes remains a fundamental challenge. Here, we investigate nonequilibrium quantum thermometry using a single-qubit probe coupled to a bosonic bath through noncommuting interaction operators, which unify pure dephasing and dissipative dynamics within a spin-boson model. We show that the interference between these two coupling channels induces strong non-Markovian feedback between populations and coherences, leading to coherence trapping and enhanced thermal sensitivity. Remarkably, by tuning the coupling structure, the probe's temperature sensitivity exhibits a quadratic low-temperature scaling, even under weak coupling. Moreover, while coherence-based measurements are formally suboptimal, they become the most informative in the early nonequilibrium regime, where memory effects dominate. Our findings identify noncommutative system-bath couplings as a practical and tunable resource for achieving high-precision quantum thermometry in realistic open-system architectures.

quant-pharXiv:2512.19607•Physical Review A•Dec 23, 2025•2 citations

Quantum thermometry in a squeezed thermal bath

H Rangani Jahromi

Abstract We address the dephasing dynamics of the quantum Fisher information for the process of quantum thermometry with probes coupled to squeezed thermal baths via the nondemolition interaction. We also calculate the upper bound for the parameter estimation and investigate how the optimal estimation is affected by the initial conditions and decoherence, particularly the squeezing parameters. Moreover, the feasibility of the optimal measurement of the temperature is discussed in detail. Then, the results are generalized for entangled probes and the multi-qubit scenarios for probing the temperature are analysed. Our results show that the squeezing can decrease the number of channel uses for optimal thermometry. Comparing different schemes for multi-qubit estimation, we find that an increase in the number of the qubits, interacting with the channel, does not necessarily vary the precision of estimating the temperature. Besides, we discuss the enhancement of the quantum thermometry using the parallel strategy and starting from the W state.

arXiv:1812.05968•Physica Scripta•Oct 15, 2019•14 citations

Global and local thermometry schemes in coupled quantum systems

Steve Campbell, Mohammad Mehboudi, Gabriele De Chiara +1 more

We study the ultimate bounds on the estimation of temperature for an interacting quantum system. We consider two coupled bosonic modes that are assumed to be thermal and using quantum estimation theory establish the role the Hamiltonian parameters play in thermometry. We show that in the case of a conserved particle number the interaction between the modes leads to a decrease in the overall sensitivity to temperature, while interestingly, if particle exchange is allowed with the thermal bath the converse is true. We explain this dichotomy by examining the energy spectra. Finally, we devise experimentally implementable thermometry schemes that rely only on locally accessible information from the total system, showing that almost Heisenberg limited precision can still be achieved, and we address the (im)possibility for multiparameter estimation in the system.

arXiv:1705.01898•New Journal of Physics•Sep 20, 2017•53 citations

Quantum metrology enhanced by coherence-induced driving in a cavity-QED setup

Weijun Cheng, S. C. Hou, Zhihai Wang +1 more

We propose a quantum metrology scheme in a cavity QED setup to achieve the Heisenberg limit. In our scheme, a series of identical two-level atoms randomly pass through and interact with a dissipative single-mode cavity. Different from the entanglement-based Heisenberg limit metrology scheme, we do not need to prepare the atomic entangled states before they enter into the cavity. We show that the initial atomic coherence will induce an effective driving to the cavity field, whose steady state is an incoherent superposition of orthogonal states, with the superposition probabilities being dependent on the atom-cavity coupling strength. By measuring the average photon number of the cavity in the steady state, we demonstrate that the root mean square of the fluctuation of the atom-cavity coupling strength is proportional to $1/{N}_{c}^{2}$ (${N}_{c}$ is the effective atom number interacting with the photon in the cavity during its lifetime). It implies that we have achieved the Heisenberg limit in our quantum metrology process. We also discuss the experimental feasibility of our theoretical proposal. Our findings may find potential applications in quantum metrology technology.

arXiv:1906.01858•Physical Review A•Nov 12, 2019•16 citations

Achieving Heisenberg scaling in low-temperature quantum thermometry

Ning Zhang, Chong Chen

We investigate correlation-enhanced low temperature quantum thermometry. Recent studies have revealed that bath-induced correlations can enhance the low-temperature estimation precision even starting from an uncorrelated state. However, a comprehensive understanding of this enhancement remains elusive. Using the Ramsey interferometry protocol, we illustrate that the estimation precision of $N$ thermometers sparsely coupled to a common low-temperature bath can achieve the Heisenberg scaling in the low-temperature regime with only a $π/2$ rotation of the measurement axis, in contrast to the standard Ramsey scheme. This result is based on the assumption that interthermometer correlations are induced exclusively by low-frequency noise in the common bath, a condition achievable in practical experimental scenarios. The underlying physical mechanism is clarified, revealing that the Heisenberg scaling arises from the intrinsic nature of the temperature, which is associated solely with the fluctuation of thermal noise. In contrast to the paradigm of independent thermometers, our proposed scheme demonstrates a significant enhancement in precision for low-temperature measurement, making it suitable for precisely measuring the temperature of ultracold systems.

arXiv:2407.05762•Jul 8, 2024•0 citations
We present a quantum thermometry scheme based on a cavity-QED setup, which attains a sensitivity with Heisenberg scaling. A stream of identical two-level systems passes through a thermal bath to be tested. Each system partially thermalizes, carrying information on the temperature of the thermal bath, and it then interacts with a dissipative single-mode cavity. The Heisenberg scaling is attained from the initial coherence of each system. The systems cannot be fully thermalized by the thermal bath. The optimal interaction time between the system and the thermal bath is derived. Direct photon detection is proved to be an optimal measurement when there is no extra thermal bath in the cavity. In the case where there is an extra thermal bath in the cavity independent of the thermal bath to be tested, homodyne detection is the optimal measurement. Moreover, we show that direct photon detection obtains less information in the case where the extra thermal bath in the cavity is in thermal equilibrium with the thermal bath. However, the optimal measurement can utilize the information from the extra thermal bath to improve the estimation precision of the temperature.
We address a particular instance where open quantum systems may be used as quantum probes for an emergent property of a complex system, as the temperature of a thermal bath. The inherent fragility of the quantum probes against decoherence is the key feature making the overall scheme very sensitive. The specific setting examined here is that of quantum thermometry, which aims to exploit decoherence as a resource to estimate the temperature of a sample. We focus on temperature estimation for a bosonic bath at equilibrium in the Ohmic regime (ranging from sub-Ohmic to super-Ohmic), by using pairs of qubits in different initial states and interacting with different environments, consisting either of a single thermal bath or of two independent ones at the same temperature. Our scheme involves pure dephasing of the probes, thus avoiding energy exchange with the sample and the consequent perturbation of temperature itself. We discuss the role of correlations among the probes and the presence of a local versus a global bath. We show that entanglement improves thermometry at short times if the two qubits are embedded in a common bath, whereas if the interaction time is not constrained, then coherence rather than entanglement is the key resource in quantum thermometry.
Accurate temperature estimation in the quantum and cryogenic regimes remains a fundamental challenge. Here, we investigate nonequilibrium quantum thermometry using a single-qubit probe coupled to a bosonic bath through noncommuting interaction operators, which unify pure dephasing and dissipative dynamics within a spin-boson model. We show that the interference between these two coupling channels induces strong non-Markovian feedback between populations and coherences, leading to coherence trapping and enhanced thermal sensitivity. Remarkably, by tuning the coupling structure, the probe's temperature sensitivity exhibits a quadratic low-temperature scaling, even under weak coupling. Moreover, while coherence-based measurements are formally suboptimal, they become the most informative in the early nonequilibrium regime, where memory effects dominate. Our findings identify noncommutative system-bath couplings as a practical and tunable resource for achieving high-precision quantum thermometry in realistic open-system architectures.
Abstract We address the dephasing dynamics of the quantum Fisher information for the process of quantum thermometry with probes coupled to squeezed thermal baths via the nondemolition interaction. We also calculate the upper bound for the parameter estimation and investigate how the optimal estimation is affected by the initial conditions and decoherence, particularly the squeezing parameters. Moreover, the feasibility of the optimal measurement of the temperature is discussed in detail. Then, the results are generalized for entangled probes and the multi-qubit scenarios for probing the temperature are analysed. Our results show that the squeezing can decrease the number of channel uses for optimal thermometry. Comparing different schemes for multi-qubit estimation, we find that an increase in the number of the qubits, interacting with the channel, does not necessarily vary the precision of estimating the temperature. Besides, we discuss the enhancement of the quantum thermometry using the parallel strategy and starting from the W state.
We study the ultimate bounds on the estimation of temperature for an interacting quantum system. We consider two coupled bosonic modes that are assumed to be thermal and using quantum estimation theory establish the role the Hamiltonian parameters play in thermometry. We show that in the case of a conserved particle number the interaction between the modes leads to a decrease in the overall sensitivity to temperature, while interestingly, if particle exchange is allowed with the thermal bath the converse is true. We explain this dichotomy by examining the energy spectra. Finally, we devise experimentally implementable thermometry schemes that rely only on locally accessible information from the total system, showing that almost Heisenberg limited precision can still be achieved, and we address the (im)possibility for multiparameter estimation in the system.
We propose a quantum metrology scheme in a cavity QED setup to achieve the Heisenberg limit. In our scheme, a series of identical two-level atoms randomly pass through and interact with a dissipative single-mode cavity. Different from the entanglement-based Heisenberg limit metrology scheme, we do not need to prepare the atomic entangled states before they enter into the cavity. We show that the initial atomic coherence will induce an effective driving to the cavity field, whose steady state is an incoherent superposition of orthogonal states, with the superposition probabilities being dependent on the atom-cavity coupling strength. By measuring the average photon number of the cavity in the steady state, we demonstrate that the root mean square of the fluctuation of the atom-cavity coupling strength is proportional to 1/Nc21/{N}_{c}^{2}1/Nc2​ (Nc{N}_{c}Nc​ is the effective atom number interacting with the photon in the cavity during its lifetime). It implies that we have achieved the Heisenberg limit in our quantum metrology process. We also discuss the experimental feasibility of our theoretical proposal. Our findings may find potential applications in quantum metrology technology.
We investigate correlation-enhanced low temperature quantum thermometry. Recent studies have revealed that bath-induced correlations can enhance the low-temperature estimation precision even starting from an uncorrelated state. However, a comprehensive understanding of this enhancement remains elusive. Using the Ramsey interferometry protocol, we illustrate that the estimation precision of NNN thermometers sparsely coupled to a common low-temperature bath can achieve the Heisenberg scaling in the low-temperature regime with only a π/2π/2π/2 rotation of the measurement axis, in contrast to the standard Ramsey scheme. This result is based on the assumption that interthermometer correlations are induced exclusively by low-frequency noise in the common bath, a condition achievable in practical experimental scenarios. The underlying physical mechanism is clarified, revealing that the Heisenberg scaling arises from the intrinsic nature of the temperature, which is associated solely with the fluctuation of thermal noise. In contrast to the paradigm of independent thermometers, our proposed scheme demonstrates a significant enhancement in precision for low-temperature measurement, making it suitable for precisely measuring the temperature of ultracold systems.