We present a method to precisely determine the
2D3/2 state lifetime of a single trapped
174Yb+ ion. This method is based on the detection of photons emitted from excited states, where a highly synchronized measurement sequence for laser control and an intensity-alternating sequence for atomic excitation and photon counting are used to minimize systematic errors. This method is easy to implement and is immune to fluctuations of magnetic field, laser intensity, and frequency detuning. Combined with the real-time approach of background photon correction, the radiative lifetime of the
2D3/2 state is determined to be $54.83\ifmmode\pm\else\textpm\fi{}0.18$ ms, which represents an order of magnitude improvement in measurement precision. The accurately determined lifetime sets a benchmark for many-body atomic theories and is particularly useful to determine the coherence time limit of the optical clock.
We report a precise determination of the lifetime of the
(4p)2P3/2 state of
40Ca+, ${\ensuremath{\tau}}_{{P}_{3/2}}=6.639(42)\phantom{\rule{0.16em}{0ex}}\mathrm{ns}$, using a combination of measurements of the induced light shift and scattering rate on a single trapped ion. Good agreement with the result of a recent high-level theoretical calculation, 6.69(6) ns [M. S. Safronova et al., Phys. Rev. A 83, 012503 (2011)], but a 6-$\ensuremath{\sigma}$ discrepancy with the most precise previous experimental value, 6.924(19) ns [J. Jin et al., Phys. Rev. Lett. 70, 3213 (1993)], is found. To corroborate the consistency and accuracy of the new measurements, relativistically corrected ratios of reduced-dipole-matrix elements are used to directly compare our result with a recent result for the
P1/2 state, yielding a good agreement. The application of the present method to precise determinations of radiative quantities of molecular systems is discussed.