Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Atom Interferometry in AN Atomic Fountain

Mark A. Kasevich

Published Jan 1, 1992• 10 citations
OpenAlex

Related papers

Pulse Schemes for Robust Atomic Fountain Interferometry

Michael H. Goerz, Mark A. Kasevich, Vladimir S. Malinovsky

Bulletin of the American Physical Society•Jun 1, 2021•0 citations

Atom Optics and Atom Interferometry

Princeton University Press eBooks•Dec 13, 2010•0 citations

Measurement of gravitational acceleration in a single laser operated atomic fountain

Kavish Bhardwaj, Shushant Kumar Singh, Surjya Prakash Ram +6 more

We present measurements on Earth's gravitational acceleration (g) using an in-house developed cold atom gravimeter (CAG) in an atomic fountain geometry. In the setup, the laser cooled $^{87}Rb$ atoms are launched vertically up in the fountain geometry and Doppler sensitive two-photon Raman pulse atom interferometry is applied to detect the gravitational acceleration experienced by the atoms. Using our gravimeter setup, we have measured the local value of 'g' in our laboratory with sensitivity of 621 $μ$Gal for integration time of 1350 s.

arXiv:2405.04223•May 7, 2024•0 citations

Atom Interferometry

Guglielmo Maria Tino

•Oct 15, 2014•26 citations

Simultaneous differential measurement of a magnetic-field gradient by atom interferometry using double fountains

Zhong-Kun Hu, Xiao‐Chun Duan, Min-Kang Zhou +4 more

Precisely measuring the magnetic-field gradient within a vacuum chamber is important for many precision experiments and can be realized by atom interferometry using magnetically sensitive sublevels at different times to make a differential measurement, which had been demonstrated in our previous work. In this paper, we demonstrate a differential method to measure the magnetic-field gradient by means of two simultaneously operated atom interferometers using double atomic fountains. By virtue of this simultaneous differential measurement to reject common-mode noise, the resolution can be improved by one order of magnitude for about a 1000-s integration time.

Physical Review A•Jul 27, 2011•34 citations

Construction of a Rubidium Fountain Atomic Interferometer for Gravity Gradiometry

JN Tinsley

Atomic interferometry is a highly precise metrological technique of interest to both fundamental and applied physics. One field in which atomic interferometry is of particular interest is gravimetry, where instruments based upon the controlled manipulation of atomic states have superseded the performance of classical devices. In such devices, a standing wave derived from laser beams with well-defined phase difference are used to impart momentum to atoms undergoing free fall, generating spatial superpositions along the axis of gravity, before returning the atoms to an overlapped final state for recombination. This thesis presents the design and experimental progress towards a gravity gradiometer based upon the interference of rubidium-87 atoms, cooled and launched in a fountain configuration. The fountain is leveraged from a decommissioned frequency standard, which has been re-purposed and redesigned for use as a combined absolute gravimeter and gravity gradiometer package. It is capable of loading 100 billion atoms in 100 ms and then cooling and launching these atoms in a moving molasses configuration, with a final temperature of 5 μK. Furthermore, the process can be quickly repeated, with a second cloud subsequently launched, reaching its apogee at the same time as the first cloud, allowing for the possibility of simultaneous measurement at different heights and, in the future, the inference of the gravity gradient. Control of the fountain is provided by a stable and miniaturised optical setup, allowing for use with a future transportable or field-based device. A Raman beam system to perform the interferometry sequence has been constructed and characterised, likewise designed in a minaturised and stable manner. The Raman beams simultaneously generated Ramsey interference fringes on two independent clouds of atoms -- one launched to a height of 0.7 m and the other to 1 m. Such fringes were clearly observable after 200 ms of evolution time. Mach-Zehnder interference fringes were also demonstrated for dropped and launched atoms, providing the capability for gravimetric measurements to be made once the system has been fully characterised. The principle causes of noise in the Mach-Zehnder cases were identified as arriving from a lack of atoms and the phase noise of the Raman beams. To overcome these challenges, a new Raman beam system has been preliminary designed and tested and a new iteration of the fountain, moving towards quantum degeneracy, has been planned.

•Jan 1, 2019•2 citations
We present measurements on Earth's gravitational acceleration (g) using an in-house developed cold atom gravimeter (CAG) in an atomic fountain geometry. In the setup, the laser cooled 87Rb^{87}Rb87Rb atoms are launched vertically up in the fountain geometry and Doppler sensitive two-photon Raman pulse atom interferometry is applied to detect the gravitational acceleration experienced by the atoms. Using our gravimeter setup, we have measured the local value of 'g' in our laboratory with sensitivity of 621 μμμGal for integration time of 1350 s.
Precisely measuring the magnetic-field gradient within a vacuum chamber is important for many precision experiments and can be realized by atom interferometry using magnetically sensitive sublevels at different times to make a differential measurement, which had been demonstrated in our previous work. In this paper, we demonstrate a differential method to measure the magnetic-field gradient by means of two simultaneously operated atom interferometers using double atomic fountains. By virtue of this simultaneous differential measurement to reject common-mode noise, the resolution can be improved by one order of magnitude for about a 1000-s integration time.
Atomic interferometry is a highly precise metrological technique of interest to both fundamental and applied physics. One field in which atomic interferometry is of particular interest is gravimetry, where instruments based upon the controlled manipulation of atomic states have superseded the performance of classical devices. In such devices, a standing wave derived from laser beams with well-defined phase difference are used to impart momentum to atoms undergoing free fall, generating spatial superpositions along the axis of gravity, before returning the atoms to an overlapped final state for recombination. This thesis presents the design and experimental progress towards a gravity gradiometer based upon the interference of rubidium-87 atoms, cooled and launched in a fountain configuration. The fountain is leveraged from a decommissioned frequency standard, which has been re-purposed and redesigned for use as a combined absolute gravimeter and gravity gradiometer package. It is capable of loading 100 billion atoms in 100 ms and then cooling and launching these atoms in a moving molasses configuration, with a final temperature of 5 μK. Furthermore, the process can be quickly repeated, with a second cloud subsequently launched, reaching its apogee at the same time as the first cloud, allowing for the possibility of simultaneous measurement at different heights and, in the future, the inference of the gravity gradient. Control of the fountain is provided by a stable and miniaturised optical setup, allowing for use with a future transportable or field-based device. A Raman beam system to perform the interferometry sequence has been constructed and characterised, likewise designed in a minaturised and stable manner. The Raman beams simultaneously generated Ramsey interference fringes on two independent clouds of atoms -- one launched to a height of 0.7 m and the other to 1 m. Such fringes were clearly observable after 200 ms of evolution time. Mach-Zehnder interference fringes were also demonstrated for dropped and launched atoms, providing the capability for gravimetric measurements to be made once the system has been fully characterised. The principle causes of noise in the Mach-Zehnder cases were identified as arriving from a lack of atoms and the phase noise of the Raman beams. To overcome these challenges, a new Raman beam system has been preliminary designed and tested and a new iteration of the fountain, moving towards quantum degeneracy, has been planned.