Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEICE Technical Report; IEICE Tech. Rep.

High-Time Resolving Dynamic AND Array for Hong-Ou-Mandel Interference

Yuichi Hasegawa, Masato Naruse, Tohru Taino, Lin Kang, Jian Chen, Peiheng Wu, Hiroaki Myoren

Published Jan 9, 2020• 0 citations
OpenAlex

Related papers

Observation of high visibility Hong-Ou-Mandel interference via a time-resolved coincidence measurement

Motoki Tanaka

The Japan Society of Applied Physics•Feb 6, 2015•0 citations

High-dimensional Hong-Ou-Mandel interference of twisted photons in a photonic chip

Hui‐Ming Wang, Mingyuan Chen, Yuan Chen +12 more

Photonics Research•Sep 11, 2026•0 citations

High‐Precision Measurement of Time Delay with Frequency‐Resolved Hong‐Ou‐Mandel Interference of Weak Coherent States

Francesco Di Lena, Fabrizio Sgobba, Danilo Triggiani +7 more

ABSTRACT We demonstrate a scheme for high‐precision measurements of time delay based on frequency‐resolved Hong‐Ou‐Mandel (HOM) interference. Our approach is applied to weak coherent states and exploits an array of single‐photon avalanche diodes (SPADs). Unlike conventional HOM experiments, our setup enables high‐precision measurements, producing an uncertainty per coincidence of about ps even for photons separated by delays up to ps so much greater than their coherence time, where ordinary non‐resolved HOM fails. This result confirms our newly developed theoretical predictions that consider, differently from previous theoretical results, a finite frequency resolution in the detection. We compare the performance of this scheme against the conventional non‐resolved case. Experimental data align well with the predictions of quantum estimation theory, demonstrating a significant reduction in the uncertainty. Due to the physics of the frequency‐resolved HOM effect, the gain in precision is particularly high when the estimated time delay is much longer than the coherence time.

arXiv:2506.03098•Advanced Quantum Technologies•Nov 28, 2025•4 citations

Enhanced Hong-Ou-Mandel manifolds and figures of merit for linear chains of identical microring resonators

Peter L. Kaulfuss, Paul M. Alsing, A. Matthew Smith +2 more

We present an exact analytic expression for the Hong-Ou-Mandel manifold (HOMM) for any number of identical microring resonators (MRRs) in a linear chain. The HOMM is the higher-dimensional manifold of solutions for which the HOM effect is obtained; for the types of MRR systems investigated in this work, it is a one-dimensional curve. We investigate the extreme stability of this HOMM, showing that the HOM effect in linear arrays of MRRs is highly robust. We further use this expression to derive three figures of merit for the HOMM of linear chains of MRRs: the minimum MRR coupling value ${\ensuremath{\tau}}_{c}$, the curvature of the one-dimensional HOMM ${\overline{\ensuremath{\xi}}}_{N}$, and the 5% tolerance in the probability for complete destructive interference to occur on the HOMM $\ensuremath{\delta}{\ensuremath{\tau}}_{N}$. We promote these metrics to characterize the pros and cons of various linear chains of MRRs and inform design and fabrication.

arXiv:2209.14837•Physical Review Research•May 12, 2023•3 citations

Hong-Ou-Mandel Interference with a Coherent Light Pulse

Sun Hyun YOUN*

New Physics Sae Mulli•Jul 30, 2021•0 citations

Many-Particle Interference

Mattia Walschaers

Springer theses•Jan 1, 2018•3 citations
ABSTRACT We demonstrate a scheme for high‐precision measurements of time delay based on frequency‐resolved Hong‐Ou‐Mandel (HOM) interference. Our approach is applied to weak coherent states and exploits an array of single‐photon avalanche diodes (SPADs). Unlike conventional HOM experiments, our setup enables high‐precision measurements, producing an uncertainty per coincidence of about ps even for photons separated by delays up to ps so much greater than their coherence time, where ordinary non‐resolved HOM fails. This result confirms our newly developed theoretical predictions that consider, differently from previous theoretical results, a finite frequency resolution in the detection. We compare the performance of this scheme against the conventional non‐resolved case. Experimental data align well with the predictions of quantum estimation theory, demonstrating a significant reduction in the uncertainty. Due to the physics of the frequency‐resolved HOM effect, the gain in precision is particularly high when the estimated time delay is much longer than the coherence time.
We present an exact analytic expression for the Hong-Ou-Mandel manifold (HOMM) for any number of identical microring resonators (MRRs) in a linear chain. The HOMM is the higher-dimensional manifold of solutions for which the HOM effect is obtained; for the types of MRR systems investigated in this work, it is a one-dimensional curve. We investigate the extreme stability of this HOMM, showing that the HOM effect in linear arrays of MRRs is highly robust. We further use this expression to derive three figures of merit for the HOMM of linear chains of MRRs: the minimum MRR coupling value ${\ensuremath{\tau}}_{c}$, the curvature of the one-dimensional HOMM ${\overline{\ensuremath{\xi}}}_{N}$, and the 5% tolerance in the probability for complete destructive interference to occur on the HOMM $\ensuremath{\delta}{\ensuremath{\tau}}_{N}$. We promote these metrics to characterize the pros and cons of various linear chains of MRRs and inform design and fabrication.