Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Concerning the possibility of radiative decay of the collective levels of the argon atom

É. T. Verkhovtseva, P. S. Pogrebnyak, Ya.M. Fogel

Published Oct 1, 1976• 2 citations
OpenAlex

Related papers

On radiative decay of an atom with two close-lying excited states

L. M. Bali, Miss R.B Higgins

Physics Letters A•May 1, 1971•3 citations

Effect of Radiative Relaxation of Excitation Anisotropy on the Measurement of Atomic Lifetime. Demonstration on Argon 2p4Level

Takashi Fujimoto, Chiaki Goto, Yasunori Uetani +1 more

We have measured the atomic lifetime of the argon 2 p 4 level by the laser-induced-fluorescence spectroscopy to be 30.5 ns. This contradicts the recent measurement using the high-frequency plused electron-beam excitation. We conjecture that, in their experiment, the radiation trapping not only affects the decay of the upper-level population but also relaxes the alignment initially produced by the electron-collision excitation in the upper-level population. Thus, the directly observed decay of the emission-line intensity is different from the decay of the upper-level population. We have observed the radiative relaxation of alignment on the neon 2 p 2 level which is a complementary effect to coherence narrowing.

Physica Scripta•Dec 1, 1983•15 citations

Decay of strontium 5 1 P 1 level on collisions with argon atoms under conditions of radiation trapping

R. I. Asadullina, Nikolai N. Bezuglov, Evgenii N. Borisov +1 more

Optics and Spectroscopy•Feb 1, 1987•3 citations

About a possibility of a decrease in the radiative width of excited levels of atoms and nuclei

И. Д. Феранчук

Physics Letters A•May 1, 1981•3 citations

Radiative decay of a pair of atoms

Martin F. H. Schuurmans

Physics Letters A•May 1, 1974•5 citations

Radiation trapping of the Hg 185 nm resonance line

Kenneth L. Menningen, James E. Lawler

The decay rate of the Hg 61P1 level was measured as a function of cold spot temperature (Hg density) and buffer gas pressure in cylindrical, sealed fused silica cells. The decay rates were obtained using a time-resolved laser-induced 185 nm fluorescence experiment with multi-step excitation. Cold spot temperatures from 25 to 100 °C were studied. The Hg densities for this temperature range and with no buffer gas yield the lowest possible decay rates due to radiation trapping with partial frequency redistribution. Decay rates with argon buffer gas pressures of 3 and 30 Torr were also studied. The results are in agreement with published data from a discharge afterglow experiment. Monte Carlo simulations of radiation transport in the cells, including the effects of hyperfine and isotope structure, the effects of foreign gas broadening, and partial frequency redistribution are compared to the experimental data. Reasonably good agreement is obtained, however there is evidence of quenching of Hg 61P1 atoms in collisions with ground state Hg and Ar atoms. An analytic formula for the fundamental mode trapped decay rate of the 61P1 level, which is applicable over a substantial region of parameter space, was devised from the Monte Carlo results.

Journal of Applied Physics•Sep 15, 2000•26 citations
We have measured the atomic lifetime of the argon 2 p 4 level by the laser-induced-fluorescence spectroscopy to be 30.5 ns. This contradicts the recent measurement using the high-frequency plused electron-beam excitation. We conjecture that, in their experiment, the radiation trapping not only affects the decay of the upper-level population but also relaxes the alignment initially produced by the electron-collision excitation in the upper-level population. Thus, the directly observed decay of the emission-line intensity is different from the decay of the upper-level population. We have observed the radiative relaxation of alignment on the neon 2 p 2 level which is a complementary effect to coherence narrowing.
The decay rate of the Hg 61P1 level was measured as a function of cold spot temperature (Hg density) and buffer gas pressure in cylindrical, sealed fused silica cells. The decay rates were obtained using a time-resolved laser-induced 185 nm fluorescence experiment with multi-step excitation. Cold spot temperatures from 25 to 100 °C were studied. The Hg densities for this temperature range and with no buffer gas yield the lowest possible decay rates due to radiation trapping with partial frequency redistribution. Decay rates with argon buffer gas pressures of 3 and 30 Torr were also studied. The results are in agreement with published data from a discharge afterglow experiment. Monte Carlo simulations of radiation transport in the cells, including the effects of hyperfine and isotope structure, the effects of foreign gas broadening, and partial frequency redistribution are compared to the experimental data. Reasonably good agreement is obtained, however there is evidence of quenching of Hg 61P1 atoms in collisions with ground state Hg and Ar atoms. An analytic formula for the fundamental mode trapped decay rate of the 61P1 level, which is applicable over a substantial region of parameter space, was devised from the Monte Carlo results.