Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Radio Engineering and Electronic Physics

Dynamic and fluctuational parameters of radio-frequency SQUIDs

Вадим Васильевич Данилов, Konstantin K. Likharev

Published Aug 1, 1980• 0 citations
OpenAlex

Related papers

Experimental study of amplitude–frequency characteristics of high-transition-temperature radio frequency superconducting quantum interference devices

Xian-Lin Zeng, Y. Zhang, Boris Chesca +3 more

We measured the amplitude–frequency characteristics of radio frequency superconducting quantum interference devices (rf SQUIDs) over a temperature range between 65 and 79 K. Using the expressions derived from the recently developed rf SQUID theory, valid also at large thermal fluctuations, we determined from these data the basic parameters of high-transition-temperature superconductor (HTS) rf SQUIDs. These parameters were: (a) the high-frequency coupling coefficient between the rf SQUID and the tank circuit resonator, k, (b) the SQUIDs hysteretic parameter, β, (c) the critical current of the Josephson junction, Ic, (d) its normal resistance, Rn, and (e) its noise parameter, Γ. We found a good agreement with the values of β(Ic) and Rn determined directly after destructively opening the SQUID loop. In accordance with the theoretical predictions, our experimental results show that at large thermal fluctuation levels (T≅77 K), rf SQUIDs with large loop inductance operate in nonhysteretic mode up to β values exceeding 3. Furthermore, we have shown that the optimal energy sensitivity is attained in the nonhysteretic mode at a value of β distinctly higher than 1. A quantitative comparison of white noise predicted by the theory with that obtained from the experiment showed a reasonable agreement. We also discussed the contribution of the phase information to the SQUID’s signal and noise at optimum operation conditions, when a mixer was used as a signal detector.

Journal of Applied Physics•Dec 1, 2000•16 citations

Dynamic and fluctuation parameters of dc SQUIDs

Вадим Васильевич Данилов, K. K. Likharev

RaEl•Apr 1, 1981•0 citations

Characterization of barrier-tunable radio-frequency-SQUID for Maxwell’s demon experiment

Gang Li, Suman Dhamala, Hao Li +2 more

We present the design, fabrication, and characterization of a barrier-tunable superconducting quantum interference device (SQUID) qubit for the study of Maxwell’s demon experiment. In this work, a compound Josephson junction (CJJ) radio-frequency (RF)-SQUID qubit with an overdamped resistively shunted direct-current (DC)-SQUID magnetometer is used to continuously monitor the state of the qubit. The circuit is successfully fabricated with the standard Nb/Al-AlO x /Nb trilayer process of our laboratory and characterized in a low noise measurement system, which is capable of measuring coherent dynamics of superconducting qubits, in an Oxford dilution refrigerator. All circuit parameters are determined accurately by fitting experimental data to theoretical analysis and simulation, which allows us to make a quantitative comparison between the results of the experiment and theory.

Chinese Physics B•Jun 1, 2018•2 citations

SIGNAL AND NOISE CHARACTERISTICS OF RF-SQUIDS

V. I. Shnyrkov, Georgy M. Tsoi

WORLD SCIENTIFIC eBooks•Jun 1, 1992•8 citations

A likelihood ratio test applied to a radio-frequency SQUID Hamiltonian

Jason F. Ralph, Terrence D. Clark, Robert J. Prance +1 more

Physics Letters A•Nov 1, 2000•2 citations

An Analysis of Non-Linear Behaviour in the Radio Frequency SQUID Magnetometer

Jason F. Ralph, Timothy P. Spiller, Terrence D. Clark +5 more

Springer proceedings in physics•Jan 1, 1992•0 citations
We measured the amplitude–frequency characteristics of radio frequency superconducting quantum interference devices (rf SQUIDs) over a temperature range between 65 and 79 K. Using the expressions derived from the recently developed rf SQUID theory, valid also at large thermal fluctuations, we determined from these data the basic parameters of high-transition-temperature superconductor (HTS) rf SQUIDs. These parameters were: (a) the high-frequency coupling coefficient between the rf SQUID and the tank circuit resonator, k, (b) the SQUIDs hysteretic parameter, β, (c) the critical current of the Josephson junction, Ic, (d) its normal resistance, Rn, and (e) its noise parameter, Γ. We found a good agreement with the values of β(Ic) and Rn determined directly after destructively opening the SQUID loop. In accordance with the theoretical predictions, our experimental results show that at large thermal fluctuation levels (T≅77 K), rf SQUIDs with large loop inductance operate in nonhysteretic mode up to β values exceeding 3. Furthermore, we have shown that the optimal energy sensitivity is attained in the nonhysteretic mode at a value of β distinctly higher than 1. A quantitative comparison of white noise predicted by the theory with that obtained from the experiment showed a reasonable agreement. We also discussed the contribution of the phase information to the SQUID’s signal and noise at optimum operation conditions, when a mixer was used as a signal detector.
We present the design, fabrication, and characterization of a barrier-tunable superconducting quantum interference device (SQUID) qubit for the study of Maxwell’s demon experiment. In this work, a compound Josephson junction (CJJ) radio-frequency (RF)-SQUID qubit with an overdamped resistively shunted direct-current (DC)-SQUID magnetometer is used to continuously monitor the state of the qubit. The circuit is successfully fabricated with the standard Nb/Al-AlO x /Nb trilayer process of our laboratory and characterized in a low noise measurement system, which is capable of measuring coherent dynamics of superconducting qubits, in an Oxford dilution refrigerator. All circuit parameters are determined accurately by fitting experimental data to theoretical analysis and simulation, which allows us to make a quantitative comparison between the results of the experiment and theory.