Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Transforming the Transmission Electron Microscope into an Electron Interferometer

G Carrillo, Rose Marie Haynes

Published Mar 8, 2018• 0 citations
OpenAlex

Related papers

Performing Electron Interferometry Using a Transmission Electron Microscope with an Thermionic Source

Rose Marie Haynes, G Carrillo, Fehmi Sami Yasin +1 more

Bulletin of the American Physical Society•Mar 6, 2018•0 citations

Developing a Quantum Electron Microscope

Christoph Kohstall, Brannon B. Klopfer, Josh Francis +3 more

Bulletin of the American Physical Society•Mar 4, 2014•0 citations

A quantum mechanical treatment of the mirror electron microscope

Aad J. Hermans, Jacobus A. Petterson

Journal of Engineering Mathematics•Apr 1, 1970•11 citations

Interaction-Free Quantum Electron Microscope in Free-Space

Yujia Yang, Chung-Soo Kim, Richard G. Hobbs +4 more

Bulletin of the American Physical Society•Mar 3, 2015•0 citations

Interaction-Free Measurement with Electrons

Amy E. Turner, Cameron Johnson, Pieter Kruit +1 more

Here, we experimentally demonstrate interaction-free measurements with electrons using a novel electron Mach-Zehnder interferometer. The flexible two-grating electron interferometer is constructed in a conventional transmission electron microscope and achieves high contrast in discrete output detectors, tunable alignment with independently movable beam splitters, and scanning capabilities for imaging. With this path-separated electron interferometer, which closely matches theoretical expectations, we demonstrate electron interaction-free measurements with an efficiency of 14±1%. Implementing this quantum protocol in electron imaging opens a path toward interaction-free electron microscopy.

Physical Review Letters•Sep 7, 2021•53 citations

Towards Integrating a Trapped-Ion Quantum-Bit in a Transmission Electron Microscope

Dominik Hornof, M. Zanetti, Nicolas Jungwirth +4 more

In electron microscopy, the pursuit of atomic-scale resolution for imaging biological [1] samples and soft-matter systems [2] is perpetually constrained by beam-induced sample degredation. While classical approaches attempt to optimize the trade-off between dose efficiency and image quality, they remain fundamentally limited by the physical interactions between electrons and the sample. Quantum technologies, however, present a transformative opportunity by enhancing information extraction per electron without increasing exposure [3], thereby breaking through classical constraints. In this work, we integrate for the first time a trapped-ion qubit into a transmission electron microscope, leveraging the strong Coulomb interaction between swift electrons and Ca⁺ ions [4], along with the precise control and readout capabilities of trapped Ca⁺ ions [5]. By harnessing quantum coherence and controlled interactions, this hybrid approach seeks to advance the capabilities of low-dose imaging, improving the analysis of radiation-sensitive samples while minimizing damage. For this purpose, we customize a transmission electron microscope to provide the required ultra-high-vacuum integrity and adapt the Ca⁺ trap design, including laser cooling and state readout/manipulation, to the geometric constraints of the microscope’s pole-piece gap.

•Apr 20, 2026•0 citations
Here, we experimentally demonstrate interaction-free measurements with electrons using a novel electron Mach-Zehnder interferometer. The flexible two-grating electron interferometer is constructed in a conventional transmission electron microscope and achieves high contrast in discrete output detectors, tunable alignment with independently movable beam splitters, and scanning capabilities for imaging. With this path-separated electron interferometer, which closely matches theoretical expectations, we demonstrate electron interaction-free measurements with an efficiency of 14±1%. Implementing this quantum protocol in electron imaging opens a path toward interaction-free electron microscopy.
In electron microscopy, the pursuit of atomic-scale resolution for imaging biological [1] samples and soft-matter systems [2] is perpetually constrained by beam-induced sample degredation. While classical approaches attempt to optimize the trade-off between dose efficiency and image quality, they remain fundamentally limited by the physical interactions between electrons and the sample. Quantum technologies, however, present a transformative opportunity by enhancing information extraction per electron without increasing exposure [3], thereby breaking through classical constraints. In this work, we integrate for the first time a trapped-ion qubit into a transmission electron microscope, leveraging the strong Coulomb interaction between swift electrons and Ca⁺ ions [4], along with the precise control and readout capabilities of trapped Ca⁺ ions [5]. By harnessing quantum coherence and controlled interactions, this hybrid approach seeks to advance the capabilities of low-dose imaging, improving the analysis of radiation-sensitive samples while minimizing damage. For this purpose, we customize a transmission electron microscope to provide the required ultra-high-vacuum integrity and adapt the Ca⁺ trap design, including laser cooling and state readout/manipulation, to the geometric constraints of the microscope’s pole-piece gap.