a Low Noise High Temperature Superconducting Quantum Interference Device

A. B. Berezin

Published Jan 1, 1993• 0 citations
OpenAlex

Related papers

Low-noise and Wide-bandwidth Current Readout at Low Temperatures Using a Superconducting-quantum-interference-device Amplifier

M. Tran, Yuma Okazaki, Shuji Nakamura +2 more

International Conference on Solid State Devices and Materials (SSDM)•Sep 28, 2016•0 citations

Characterization of the low-frequency noise in high-temperature radio frequency superconducting quantum interference devices cooled in static magnetic fields

J. Borgmann, P. David, Raphael Otto +2 more

We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.

Applied Physics Letters•Feb 15, 1999•1 citation

Superconducting Quantum Interference Devices for Low Frequency Measurements

John L. Clarke

Springer eBooks•Jan 1, 1977•57 citations

Multi-terminal superconducting quantum interference device

Hanho Lee, Natalia Pankratova, Roman Kuzmin +4 more

Bulletin of the American Physical Society•Mar 4, 2020•0 citations

Nano-superconducting quantum interference devices with continuous read out at milliKelvin temperatures

Dibyendu Hazra, John R. Kirtley, K. Hasselbach

We describe aluminum-niobium-tungsten trilayer Nano-Superconducting Quantum Interference Devices (NanoSQUIDs) that can be read out continuously down, in temperature, to at least 230 mK. They show voltage oscillations up to at least 20 mT in field. A voltage modulation of 500 μV, voltage sensitivity of 2 mV/Φ0, and white noise floor better than 5×10−5 Φ0/Hz have been obtained. Flux noise places them between conventional low impedance SQUIDs and standard nanoSQUIDs. High sensitivity and ease of implementation make this new kind of nanoSQUID attractive for magnetic detection schemes on the nanoscale and low temperature scanning SQUID microscopy.

Applied Physics Letters•Aug 26, 2013•24 citations

Substrate step-edge YBa2Cu3O7 rf SQUIDs

K.P. Daly, William D. Dozier, John F. Burch +4 more

We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.

Applied Physics Letters•Feb 4, 1991•133 citations
We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.
We describe aluminum-niobium-tungsten trilayer Nano-Superconducting Quantum Interference Devices (NanoSQUIDs) that can be read out continuously down, in temperature, to at least 230 mK. They show voltage oscillations up to at least 20 mT in field. A voltage modulation of 500 μV, voltage sensitivity of 2 mV/Φ0, and white noise floor better than 5×10−5 Φ0/Hz have been obtained. Flux noise places them between conventional low impedance SQUIDs and standard nanoSQUIDs. High sensitivity and ease of implementation make this new kind of nanoSQUID attractive for magnetic detection schemes on the nanoscale and low temperature scanning SQUID microscopy.
We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.