Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Journal of Theoretical Physics

Enhancing Quantum Parameter Estimation in Open Quantum System by Dynamical Decoupling Pulses

Yinghua Ji, Juju Hu

Published Mar 23, 2020• 2 citations
Publisher
DOI
10.1007/s10773-020-04426-z

Related papers

Dynamical decoupling-assisted quantum parameter estimation with initial system-environment correlations

Yinghua Ji, Juju Hu

Optik•Sep 30, 2020•2 citations

Quantum speedup of uncoupled multiqubit open system via dynamical decoupling pulses

Ya‐Ju Song, Le‐Man Kuang, Qing-Shou Tan

arXiv:1508.04622•Quantum Information Processing•Mar 15, 2016•15 citations

Enhancement of parameter-estimation precision in noisy systems by dynamical decoupling pulses

Qing-Shou Tan, Yixiao Huang, Xiaolei Yin +2 more

We present a scheme to enhance the precision of parameter estimation (PPE) in noisy systems by employing dynamical decoupling pulses. An exact analytical expression for the estimation precision of an unknown parameter is obtained by using the transfer matrix and time-dependent Kraus operators. We show that the PPE in noisy systems can be preserved in the Heisenberg limit by control of the dynamical decoupling pulses. It is found that a larger number of pulses and longer reservoir correlation time can greatly protect the PPE.

Physical Review A•Mar 4, 2013•78 citations

Dynamics of Open Quantum Systems

Jacek Okołowicz, Marek Płoszajczak, I. Rotter

arXiv:nucl-th/0301094•Springer eBooks•Jan 1, 2004•1 citation

Dephasing-assisted parameter estimation in the presence of dynamical decoupling

Qing-Shou Tan, Yixiao Huang, Le‐Man Kuang +1 more

We study the dephasing-assisted parameter estimation precision (PEP) enhancement in an atom interferometer with dynamical decoupling (DD) pulses. Through calculating the spin squeezing (SS) and the quantum Fisher information, we find that dephasing noise can improve PEP by inducing SS, and the DD pulses can maximize the improvement. It is indicated that when using the DD pulse the dephasing-induced SS can reach the limit of ``one-axis twisting'' model ${\ensuremath{\xi}}^{2}\ensuremath{\simeq}{N}^{\ensuremath{-}2/3}$ with ${\ensuremath{\xi}}^{2}$ being the SS parameter and $N$ the number of atoms. In particular, we find that the DD pulses can amplify the dephasing-induced quantum Fisher information by a factor of $\ensuremath{\simeq}N/2$ compared with the noise-free case, which means that under the control of DD pulses, the dephasing noise can enhance the precision of parameter estimation to the scale of $\sqrt{2}/N$, the same scale of the Heisenberg limit ($1/N$).

arXiv:1306.0642•Physical Review A•Jun 4, 2014•26 citations

Optimal pulse spacing for dynamical decoupling in the presence of a purely dephasing spin bath

Ashok Ajoy, Gonzalo A. Álvarez, Dieter Suter

Maintaining quantum coherence is a crucial requirement for quantum computation; hence protecting quantum systems against their irreversible corruption due to environmental noise is an important open problem. Dynamical decoupling (DD) is an effective method for reducing decoherence with a low control overhead. It also plays an important role in quantum metrology, where, for instance, it is employed in multiparameter estimation. While a sequence of equidistant control pulses [the Carr-Purcell-Meiboom-Gill (CPMG) sequence] has been ubiquitously used for decoupling, Uhrig recently proposed that a nonequidistant pulse sequence [the Uhrig dynamic decoupling (UDD) sequence] may enhance DD performance, especially for systems where the spectral density of the environment has a sharp frequency cutoff. On the other hand, equidistant sequences outperform UDD for soft cutoffs. The relative advantage provided by UDD for intermediate regimes is not clear. In this paper, we analyze the relative DD performance in this regime experimentally, using solid-state nuclear magnetic resonance. Our system qubits are $^{13}\mathrm{C}$ nuclear spins and the environment consists of a $^{1}\mathrm{H}$ nuclear spin bath whose spectral density is close to a normal (Gaussian) distribution. We find that in the presence of such a bath, the CPMG sequence outperforms the UDD sequence. An analogy between dynamical decoupling and interference effects in optics provides an intuitive explanation as to why the CPMG sequence performs better than any nonequidistant DD sequence in the presence of this kind of environmental noise.

arXiv:1011.6243•Physical Review A•Mar 8, 2011•122 citations
We present a scheme to enhance the precision of parameter estimation (PPE) in noisy systems by employing dynamical decoupling pulses. An exact analytical expression for the estimation precision of an unknown parameter is obtained by using the transfer matrix and time-dependent Kraus operators. We show that the PPE in noisy systems can be preserved in the Heisenberg limit by control of the dynamical decoupling pulses. It is found that a larger number of pulses and longer reservoir correlation time can greatly protect the PPE.
We study the dephasing-assisted parameter estimation precision (PEP) enhancement in an atom interferometer with dynamical decoupling (DD) pulses. Through calculating the spin squeezing (SS) and the quantum Fisher information, we find that dephasing noise can improve PEP by inducing SS, and the DD pulses can maximize the improvement. It is indicated that when using the DD pulse the dephasing-induced SS can reach the limit of ``one-axis twisting'' model ${\ensuremath{\xi}}^{2}\ensuremath{\simeq}{N}^{\ensuremath{-}2/3}$ with ${\ensuremath{\xi}}^{2}$ being the SS parameter and NNN the number of atoms. In particular, we find that the DD pulses can amplify the dephasing-induced quantum Fisher information by a factor of $\ensuremath{\simeq}N/2$ compared with the noise-free case, which means that under the control of DD pulses, the dephasing noise can enhance the precision of parameter estimation to the scale of 2/N\sqrt{2}/N2​/N, the same scale of the Heisenberg limit (1/N1/N1/N).
Maintaining quantum coherence is a crucial requirement for quantum computation; hence protecting quantum systems against their irreversible corruption due to environmental noise is an important open problem. Dynamical decoupling (DD) is an effective method for reducing decoherence with a low control overhead. It also plays an important role in quantum metrology, where, for instance, it is employed in multiparameter estimation. While a sequence of equidistant control pulses [the Carr-Purcell-Meiboom-Gill (CPMG) sequence] has been ubiquitously used for decoupling, Uhrig recently proposed that a nonequidistant pulse sequence [the Uhrig dynamic decoupling (UDD) sequence] may enhance DD performance, especially for systems where the spectral density of the environment has a sharp frequency cutoff. On the other hand, equidistant sequences outperform UDD for soft cutoffs. The relative advantage provided by UDD for intermediate regimes is not clear. In this paper, we analyze the relative DD performance in this regime experimentally, using solid-state nuclear magnetic resonance. Our system qubits are 13C^{13}\mathrm{C}13C nuclear spins and the environment consists of a 1H^{1}\mathrm{H}1H nuclear spin bath whose spectral density is close to a normal (Gaussian) distribution. We find that in the presence of such a bath, the CPMG sequence outperforms the UDD sequence. An analogy between dynamical decoupling and interference effects in optics provides an intuitive explanation as to why the CPMG sequence performs better than any nonequidistant DD sequence in the presence of this kind of environmental noise.