Classical and Quantum Gravity

Quantum enhanced kHz gravitational wave detector with internal squeezing

V. B. Adya, M. J. Yap, Daniel Töyrä, T. McRae, P. A. Altin, L K Sarre, M Meijerink, N. Kijbunchoo, Bram J. J. Slagmolen, Robert L. Ward, David E. McClelland

Published Feb 13, 2020• 22 citations
Publisher

Abstract

Abstract We propose adding a nonlinear element to a long signal recycling cavity to enhance the high-frequency sensitivity (900 Hz–5 kHz) of a kilometer-scale interferometric gravitational wave detector. Using numbers for absorption and scattering losses in the detector consistent with advanced LIGO+, we demonstrate a factor of 3.5 improvement in quantum noise limited strain sensitivity in the kHz regime. Such a configuration is robust to internal losses and reduces the requirement on the amount of circulating power in the detector to achieve sensitivity comparable to future gravitational wave detectors. This proposed configuration is compatible with the existing gravitational wave detector vacuum infrastructure and could enable exploration of exotic science, such as observing the merger phase of binary neutron stars, which in turn may provide constraints on the neutron star equation of state.

DOI
10.1088/1361-6382/ab7615

Related papers

Broadband Quantum Enhancement of the LIGO Detectors with Frequency-Dependent Squeezing

D. Ganapathy, W. Jia, M. Nakano +97 more

Quantum noise imposes a fundamental limitation on the sensitivity of interferometric gravitationalwave detectors like LIGO, manifesting as shot noise and quantum radiation pressure noise.Here, we present the first realization of frequency-dependent squeezing in full-scale gravitational-wave detectors, resulting in the reduction of both shot noise and quantum radiation pressure noise, with broadband detector enhancement from tens of hertz to several kilohertz.In the LIGO Hanford detector, squeezing reduced the detector noise amplitude by a factor of 1.6 (4.0 dB) near 1 kHz; in the Livingston detector, the noise reduction was a factor of 1.9 (5.8 dB).These improvements directly impact LIGO's scientific output for high-frequency sources (e.g., binary neutron star postmerger physics).The improved lowfrequency sensitivity, which boosted the detector range by 15%-18% with respect to no squeezing, corresponds to an increase in the astrophysical detection rate of up to 65%.Frequency-dependent squeezing was enabled by the addition of a 300-meter-long filter cavity to each detector as part of the LIGO Aþ upgrade.

Physical Review X•Oct 30, 2023•149 citations

Quantum noise reduction using squeezed states in LIGO

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics

•Jan 1, 2013•14 citations

Quantum limited measurements in gravitational wave detectors

Andrew R. Wade

Gravitational waves manifest as a time varying straining of space: they arise from the accelerating motions of large bodies of mass and propagate across the universe at the speed of light as ripples in the fabric of space-time, a fleetingly weak effect so far eluding direct detection. The detection of gravitation waves is expected to yield a rich vein to observational astronomy, complementing existing electromagnetic surveys and revealing a hitherto unexplored range of phenomena. First generation interferometric gravitational wave detectors, notably Enhanced LIGO, achieved strain sensitivities of one part in ten to power twenty-one per square-root-Hertz at 100 Hz with an expected detection rate of 2-3 events per year. Commissioning of a new generation of Advanced LIGO interferometric detectors has concluded recently with a resultant ten-fold sensitivity improvement. Overall their potential event detection space has increased by a factor of 1000. The quantum nature of light within these detectors now limits their sensitivity over most of their frequency range. This quantum noise limit is driven by the vacuum quadrature fluctuations propagated through their open detection ports and represents a fundamental noise floor to their strain sensitivity. This thesis addresses two distinct approaches to quantum noise improvement for future upgrades to advanced detectors. The first addresses the issue of quantum noise by adopting a quantum non-demolition approach to detector readout variables, the so-called `speed-meter’ design. Such a modified instrument samples test mass momentum, a quantity for which time separated measurements commute and are therefore not bound by Heisenberg-like limits. A novel polarisation-folded sloshing cavity type speed-meter is proposed where readout fields are stored and delayed in the orthogonal polarisation of the interferometer’s arms cavities. Here frequency dependence is selected to cancel position like measurements so that only test mass momentum information remains. A quantum noise propagation model is developed and a sensitivity performance is demonstrated that beats the standard quantum limit below 100 Hz over a broad range of frequencies. A second approach to achieve quantum noise enhancement in advanced detectors involves injection of quadrature-squeezed states in the place of vacuum. This dissertation details the development of a prototype squeezed vacuum source suitable to the demanding enhancement requirements for an Advanced LIGO squeezing installation. The construction of a doubly resonant, bow-tie cavity source is presented. This employs a novel monolithic all-glass cavity construction and is vacuum compatible. This design demonstrates the viability of building a cavity using optical contacting as a construction technique for attaching mounting prisms to highly polished fused-silica breadboards. Such a design can be expected to have excellent length noise stability, provide low intrinsic phase noise and would be suitable to mount on seismic isolation stages within the LIGO vacuum envelope. Further, the travelling wave cavity design should provide excellent 50 dB intrinsic backscatter isolation. We demonstrate the first operation of such a complex non-linear device under vacuum, producing 8.6 dB of measured vacuum squeezing down to 10 Hz across the advanced LIGO ‘audio-band’ detection range.

•Jan 1, 2016•0 citations

Quantum enhancement of a 4km laser interferometer gravitational-wave detector

S. Chua

The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.

•Jan 1, 2013•1 citation

Quantum noise reduction using squeezed states inLIGO; Sensitivity improvement of a LIGO gravitational Waynedetector through squeezed state injection

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.

•Jan 1, 2013•0 citations

Coherent feedback for quantum expander in gravitational wave observatories

N. Boettner, J. D. Bentley, Roman Schnabel +1 more

The observation of gravitational waves from binary neutron star mergers offers insights into properties of extreme nuclear matter. However, their high-frequency signals in the kHz range are often masked by quantum noise of the laser light used. Here, we propose the ``quantum expander with coherent feedback,'' a new detector design that features an additional optical cavity in the detector output and an internal squeeze operation. This approach allows us to boost the sensitivity at high frequencies while at the same time providing a compact and tunable design for signal extraction. It also allows us to tailor the sensitivity of the detector to the specific signal frequency range. We demonstrate that our design can improve the sensitivity of the high-frequency detector concept NEMO, increasing the detection rates by around 14%. Our approach promises a new level of flexibility in designing the detectors aimed at high-frequency signals.

arXiv:2403.03758•Physical review. D/Physical review. D.•Nov 12, 2024•2 citations
Abstract We propose adding a nonlinear element to a long signal recycling cavity to enhance the high-frequency sensitivity (900 Hz–5 kHz) of a kilometer-scale interferometric gravitational wave detector. Using numbers for absorption and scattering losses in the detector consistent with advanced LIGO+, we demonstrate a factor of 3.5 improvement in quantum noise limited strain sensitivity in the kHz regime. Such a configuration is robust to internal losses and reduces the requirement on the amount of circulating power in the detector to achieve sensitivity comparable to future gravitational wave detectors. This proposed configuration is compatible with the existing gravitational wave detector vacuum infrastructure and could enable exploration of exotic science, such as observing the merger phase of binary neutron stars, which in turn may provide constraints on the neutron star equation of state.
Quantum noise imposes a fundamental limitation on the sensitivity of interferometric gravitationalwave detectors like LIGO, manifesting as shot noise and quantum radiation pressure noise.Here, we present the first realization of frequency-dependent squeezing in full-scale gravitational-wave detectors, resulting in the reduction of both shot noise and quantum radiation pressure noise, with broadband detector enhancement from tens of hertz to several kilohertz.In the LIGO Hanford detector, squeezing reduced the detector noise amplitude by a factor of 1.6 (4.0 dB) near 1 kHz; in the Livingston detector, the noise reduction was a factor of 1.9 (5.8 dB).These improvements directly impact LIGO's scientific output for high-frequency sources (e.g., binary neutron star postmerger physics).The improved lowfrequency sensitivity, which boosted the detector range by 15%-18% with respect to no squeezing, corresponds to an increase in the astrophysical detection rate of up to 65%.Frequency-dependent squeezing was enabled by the addition of a 300-meter-long filter cavity to each detector as part of the LIGO Aþ upgrade.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics
Gravitational waves manifest as a time varying straining of space: they arise from the accelerating motions of large bodies of mass and propagate across the universe at the speed of light as ripples in the fabric of space-time, a fleetingly weak effect so far eluding direct detection. The detection of gravitation waves is expected to yield a rich vein to observational astronomy, complementing existing electromagnetic surveys and revealing a hitherto unexplored range of phenomena. First generation interferometric gravitational wave detectors, notably Enhanced LIGO, achieved strain sensitivities of one part in ten to power twenty-one per square-root-Hertz at 100 Hz with an expected detection rate of 2-3 events per year. Commissioning of a new generation of Advanced LIGO interferometric detectors has concluded recently with a resultant ten-fold sensitivity improvement. Overall their potential event detection space has increased by a factor of 1000. The quantum nature of light within these detectors now limits their sensitivity over most of their frequency range. This quantum noise limit is driven by the vacuum quadrature fluctuations propagated through their open detection ports and represents a fundamental noise floor to their strain sensitivity. This thesis addresses two distinct approaches to quantum noise improvement for future upgrades to advanced detectors. The first addresses the issue of quantum noise by adopting a quantum non-demolition approach to detector readout variables, the so-called `speed-meter’ design. Such a modified instrument samples test mass momentum, a quantity for which time separated measurements commute and are therefore not bound by Heisenberg-like limits. A novel polarisation-folded sloshing cavity type speed-meter is proposed where readout fields are stored and delayed in the orthogonal polarisation of the interferometer’s arms cavities. Here frequency dependence is selected to cancel position like measurements so that only test mass momentum information remains. A quantum noise propagation model is developed and a sensitivity performance is demonstrated that beats the standard quantum limit below 100 Hz over a broad range of frequencies. A second approach to achieve quantum noise enhancement in advanced detectors involves injection of quadrature-squeezed states in the place of vacuum. This dissertation details the development of a prototype squeezed vacuum source suitable to the demanding enhancement requirements for an Advanced LIGO squeezing installation. The construction of a doubly resonant, bow-tie cavity source is presented. This employs a novel monolithic all-glass cavity construction and is vacuum compatible. This design demonstrates the viability of building a cavity using optical contacting as a construction technique for attaching mounting prisms to highly polished fused-silica breadboards. Such a design can be expected to have excellent length noise stability, provide low intrinsic phase noise and would be suitable to mount on seismic isolation stages within the LIGO vacuum envelope. Further, the travelling wave cavity design should provide excellent 50 dB intrinsic backscatter isolation. We demonstrate the first operation of such a complex non-linear device under vacuum, producing 8.6 dB of measured vacuum squeezing down to 10 Hz across the advanced LIGO ‘audio-band’ detection range.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.
The observation of gravitational waves from binary neutron star mergers offers insights into properties of extreme nuclear matter. However, their high-frequency signals in the kHz range are often masked by quantum noise of the laser light used. Here, we propose the ``quantum expander with coherent feedback,'' a new detector design that features an additional optical cavity in the detector output and an internal squeeze operation. This approach allows us to boost the sensitivity at high frequencies while at the same time providing a compact and tunable design for signal extraction. It also allows us to tailor the sensitivity of the detector to the specific signal frequency range. We demonstrate that our design can improve the sensitivity of the high-frequency detector concept NEMO, increasing the detection rates by around 14%. Our approach promises a new level of flexibility in designing the detectors aimed at high-frequency signals.