Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Metrologia

Improved Raman pulse sequence for rotation measurements with atom interferometers

Yu-Jie Tan, Miaomiao Zhao, Panpan Wang, Yajie Wang, Yaoyao Xu, Xiao‐Chun Duan, Cheng-Gang Shao, Zhong-Kun Hu

Published May 6, 2020• 6 citations
Publisher

Abstract

Since the double-loop atom interferometer consisting of Raman π 2 − π − π − π 2 four-pulse sequences can eliminate the dependence of the interferometric phase shift on the atomic initial velocity, it is widely used for rotation measurements. However, our research shows that by coupling itself with both the atomic initial velocity and the laser detuning, the short pulse duration can contribute to unknown systematic errors within the current instrument sensitivity. The coupling of the pulse duration with the laser detuning inside the device is verified experimentally and presented in this work. An improved pulse sequence design is developed to eliminate these systematic errors and improve the precision of the rotation measurements.

DOI
10.1088/1681-7575/ab7174

Related papers

Improved frequency shift compensation technique and pulse sequence for multi-loop atom interference experiments

Ya-Jie Wang, Xiaoyu Lu, Jiao Zhang +6 more

With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.

Physica Scripta•Sep 9, 2024•1 citation

Can optimised pulses improve the sensitivity of atom interferometers?

Jack Saywell, Max Carey, Nikolaos Dedes +2 more

The sensitivity of atom interferometers depends on the fidelity of the light pulses used as beamsplitters and mirrors. Atom interferometers typically employ pulses that affect π/2 and π fractional Rabi oscillations, the fidelities of which are reduced when there are variations in atomic velocity and laser intensity. We have previously demonstrated the application of optimal control theory to design pulses more robust to such errors; however, if these variations exhibit a time dependence over periods on the order of the interferometer duration then phase shifts can be introduced in the final fringe that potentially reduce the sensitivity. In this paper, we explain why care must be taken when optimising interferometer pulse sequences to ensure that phase shifts arising from inter-pulse variations are not significantly increased. We show that these phase shifts can in fact be minimised by choosing an appropriate measure of individual pulse fidelity.

Quantum Technology: Driving Commercialisation of an Enabling Science•Oct 6, 2021•4 citations

Dependence of sensitivity of atom interferometer gravimeters on the Raman laser pulse sequences

Ren Li-Chun, Zhou Lin, Runbing Li +4 more

We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.

Acta Physica Sinica•Jan 1, 2009•4 citations

Dual-atom-interferometric gyroscope with continuous cold atomic beams

Shengzhe Wang, Zhixin Meng, Peiqiang Yan +1 more

In closed-loop dual-atom interferometers, the initial phase shift is a non-inertial phase induced by Raman pulses. This initial optical phase affects the measurements of both acceleration and rotation rate. In this study, we present a method to modulate the initial optical phase of light pulse atom interferometers (LPAIs). Employing this modulation method, we investigated the influence of the initial optical phase on a closed-loop dual-atom interferometer. The results reveal a better short-term sensitivity in the rotation rate measurement at an initial optical phase of 0. Our closed-loop dual-atom interferometer allows for decoupled measurements of rotation rate and acceleration. With a short interrogation time of 2T = 1.73 ms, the short-term sensitivities of the rotation rate and acceleration measurements are 2.73 × 10 − 5 ( rad / s ) / Hz and 272 μ g / Hz , respectively.

Journal of Physics Conference Series•Nov 1, 2024•1 citation

The Effect of Imperfect Raman Pulses on the Atomic Interference Signal

M.M. Zhao, Y.J. Tan, C.G. Shao

Imperfect Raman pulses can lead to the formation of multiple interfering paths and affect the output of an atom interferometer in high-precision measurement.We study the effect of the imperfect Raman pulses on the interferometric fringe contrast and the phase shift in the three-pulse atom interferometer by using the evolution operator method.Analytical expressions expanded to the second-order fluctuation of imperfect pulses are derived, in which the effect of coupling the imperfect pulses with laser detuning and pulse duration is also considered.The result indicates that the second-order fluctuation of imperfect pulses is dominant, however, it can be nearly ignored in the current requirements of atomic experiments.Even so, theoretical analysis is very necessary as it may be helpful in proposing some schemes to improve the interference efficiency for future high-precision measurements with atomic interferometry.

Acta Physica Polonica A•Aug 1, 2022•0 citations

Temporal pulse origins in atom-interferometric quantum sensors

Jack Saywell, Nikolaos Dedes, Max Carey +2 more

Quantum sensors based upon atom interferometry typically rely on radio-frequency or optical pulses to coherently manipulate atomic states and make precise measurements of inertial and gravitational effects. An advantage of these sensors over their classical counterparts is often said to be that their measurement scale factor is precisely known and highly stable; however, in practice the finite pulse duration makes the sensor scale factor dependent upon the pulse shape and sensitive to variations in control-field intensity, frequency, and atomic velocity. Here, we explore the concept of a temporal pulse origin in atom interferometry, where the inertial phase response of any pulse can be parameterized using a single point in time. We show that the temporal origin permits a simple determination of the measurement scale factor and its stability against environmental perturbations. Moreover, the temporal origin can be treated as a tunable parameter in the design of tailored sequences of shaped pulses to enhance scale-factor stability and minimize systematic errors. We demonstrate through simulations that this approach to pulse design can reduce overall sequence durations while increasing robustness to realistic fluctuations in control-field amplitude. Our results show that the temporal pulse origin explains a broad class of systematic errors in existing devices and enables the design of short, robust pulses, which we expect will improve the performance of current and next-generation interferometric quantum sensors.

arXiv:2510.01900•Physical Review Applied•Feb 18, 2026•2 citations
Since the double-loop atom interferometer consisting of Raman π 2 − π − π − π 2 four-pulse sequences can eliminate the dependence of the interferometric phase shift on the atomic initial velocity, it is widely used for rotation measurements. However, our research shows that by coupling itself with both the atomic initial velocity and the laser detuning, the short pulse duration can contribute to unknown systematic errors within the current instrument sensitivity. The coupling of the pulse duration with the laser detuning inside the device is verified experimentally and presented in this work. An improved pulse sequence design is developed to eliminate these systematic errors and improve the precision of the rotation measurements.
With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.
The sensitivity of atom interferometers depends on the fidelity of the light pulses used as beamsplitters and mirrors. Atom interferometers typically employ pulses that affect π/2 and π fractional Rabi oscillations, the fidelities of which are reduced when there are variations in atomic velocity and laser intensity. We have previously demonstrated the application of optimal control theory to design pulses more robust to such errors; however, if these variations exhibit a time dependence over periods on the order of the interferometer duration then phase shifts can be introduced in the final fringe that potentially reduce the sensitivity. In this paper, we explain why care must be taken when optimising interferometer pulse sequences to ensure that phase shifts arising from inter-pulse variations are not significantly increased. We show that these phase shifts can in fact be minimised by choosing an appropriate measure of individual pulse fidelity.
We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.
In closed-loop dual-atom interferometers, the initial phase shift is a non-inertial phase induced by Raman pulses. This initial optical phase affects the measurements of both acceleration and rotation rate. In this study, we present a method to modulate the initial optical phase of light pulse atom interferometers (LPAIs). Employing this modulation method, we investigated the influence of the initial optical phase on a closed-loop dual-atom interferometer. The results reveal a better short-term sensitivity in the rotation rate measurement at an initial optical phase of 0. Our closed-loop dual-atom interferometer allows for decoupled measurements of rotation rate and acceleration. With a short interrogation time of 2T = 1.73 ms, the short-term sensitivities of the rotation rate and acceleration measurements are 2.73 × 10 − 5 ( rad / s ) / Hz and 272 μ g / Hz , respectively.
Imperfect Raman pulses can lead to the formation of multiple interfering paths and affect the output of an atom interferometer in high-precision measurement.We study the effect of the imperfect Raman pulses on the interferometric fringe contrast and the phase shift in the three-pulse atom interferometer by using the evolution operator method.Analytical expressions expanded to the second-order fluctuation of imperfect pulses are derived, in which the effect of coupling the imperfect pulses with laser detuning and pulse duration is also considered.The result indicates that the second-order fluctuation of imperfect pulses is dominant, however, it can be nearly ignored in the current requirements of atomic experiments.Even so, theoretical analysis is very necessary as it may be helpful in proposing some schemes to improve the interference efficiency for future high-precision measurements with atomic interferometry.
Quantum sensors based upon atom interferometry typically rely on radio-frequency or optical pulses to coherently manipulate atomic states and make precise measurements of inertial and gravitational effects. An advantage of these sensors over their classical counterparts is often said to be that their measurement scale factor is precisely known and highly stable; however, in practice the finite pulse duration makes the sensor scale factor dependent upon the pulse shape and sensitive to variations in control-field intensity, frequency, and atomic velocity. Here, we explore the concept of a temporal pulse origin in atom interferometry, where the inertial phase response of any pulse can be parameterized using a single point in time. We show that the temporal origin permits a simple determination of the measurement scale factor and its stability against environmental perturbations. Moreover, the temporal origin can be treated as a tunable parameter in the design of tailored sequences of shaped pulses to enhance scale-factor stability and minimize systematic errors. We demonstrate through simulations that this approach to pulse design can reduce overall sequence durations while increasing robustness to realistic fluctuations in control-field amplitude. Our results show that the temporal pulse origin explains a broad class of systematic errors in existing devices and enables the design of short, robust pulses, which we expect will improve the performance of current and next-generation interferometric quantum sensors.