Journal of Low Temperature Physics

Properties of a Nanowire Kinetic Inductance Detector Array

Jacob Glasby, Adrian K. Sinclair, Philip D. Mauskopf, Hamdi Mani, Di Zhu, Marco Colangelo, Karl K. Berggren

Published Dec 23, 2019• 1 citation
Publisher
DOI
10.1007/s10909-019-02288-2

Related papers

Development of Large Array of Kinetic Inductance Detectors Using Commercial-Class External Foundries

K. Kiuchi, S. Oguri, S. Mima +2 more

Journal of Low Temperature Physics•Apr 23, 2020•3 citations

Development of large array horn coupled superconducting kinetic inductance detectors

K. Kiuchi, Chiko Otani, S. Oguri +8 more

IEICE Technical Report; IEICE Tech. Rep.•Aug 1, 2016•0 citations

Thermal relaxation and kinetic inductance in superconducting nanowires used as single photon detectors

Anthony J. Annunziata, Daniel F. Santavicca, Joel Chudow +5 more

Bulletin of the American Physical Society•Mar 17, 2010•0 citations

Temperature Dependence of Kinetic Inductance in a WSi Superconducting Nanowire Single-Photon Detector

Kathryn L. Nicolich, Clinton Cahall, Gregory P. Lafyatis +5 more

Bulletin of the American Physical Society•Mar 16, 2017•0 citations

Lumped Element Kinetic Inductance Detectors

Simon M. Doyle, Philip D. Mauskopf, Jack Alexander Naylon +2 more

Journal of Low Temperature Physics•Jan 10, 2008•274 citations

Development of an Array of Kinetic Inductance Magnetometers (KIMs)

Sasha Sypkens, Farzad Faramarzi, Marco Colangelo +6 more

We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).

arXiv:2102.11001•IEEE Transactions on Applied Superconductivity•Feb 3, 2021•3 citations
We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).