Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Development and Characterization of a Ytterbium-171 Miniature Ion Trap Frequency Standard

Heather L. Partner

Published Jan 1, 2012• 0 citations
OpenAlex

Related papers

Miniature trapped-ion frequency standard with 171Yb+; Proceedings.

Peter D. D. Schwindt, Yuan‐Yu Jau, Heather L. Partner +14 more

•Apr 1, 2015•0 citations

Miniature trapped-ion frequency standard with 171Yb+.

Peter D. D. Schwindt, Yuan-Yu Jau, Heather Partner +11 more

•May 4, 2016•5 citations

Towards a Microwave-Laser Double Resonance Passive Frequency Standard Using Trapped Ytterbium Ions.

David J. Seidel

•Jan 1, 1995•0 citations

Implementation of an Ytterbium 171 Trapped Ion Qubit

Naleli Jubert Matjelo

•Apr 1, 2020•3 citations

Micro Ion Frequency Standard

Peter D. D. Schwindt, Roy H. Olsson, K.E. Wojciechowski +7 more

We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.

•Nov 19, 2009•2 citations

Development and Characterization of a 171Yb+ Miniature Ion Trap Frequency Standard

Heather L. Partner

This dissertation reports on the development of a low-power, high-stability miniature atomic frequency standard based on 171Yb+ ions. The ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed, getter-pumped vacuum package, and interrogated on the 12.6 GHz hyperfine transition. We hope to achieve a long-term fractional frequency stability of 10^-14 with a miniature clock that consumes only 50 mW of power and occupies a volume of 5 cm^3. I discuss our progress over several years of work on this project. We began by building a conventional tabletop clock to use as a test bed while developing several designs of miniature ion-trap vacuum packages, while also developing techniques for various aspects of the clock operation, including ion loading, laser and magnetic field stabilization, and a low power ion trap drive. The ion traps were modeled using boundary element software to assist with the design and parameter optimization of new trap geometries. We expect a novel trap geometry that uses a material new to ion traps to lead to an exceptionally small ion trap vacuum package in the next phase of the project. To achieve the long-term stability required, we have also considered the sensitivity of the clock frequency to magnetic fields. A study of the motion of the individual ions in a room-temperature cloud in the trap was performed with the purpose of understanding the effect of both spatially varying and constant magnetic fields on the clock resonance and therefore the operation of the clock. These effects were studied experimentally and theoretically for several traps. In summary, this dissertation is a contribution to the design, development, and testing of a 171Yb+ ion cloud frequency standard and related techniques, including analyses of trap geometries and parameters, modeling of the ion motion, and the practical operation of the clock.

arXiv:1208.5622•Aug 28, 2012•4 citations
We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.
This dissertation reports on the development of a low-power, high-stability miniature atomic frequency standard based on 171Yb+ ions. The ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed, getter-pumped vacuum package, and interrogated on the 12.6 GHz hyperfine transition. We hope to achieve a long-term fractional frequency stability of 10^-14 with a miniature clock that consumes only 50 mW of power and occupies a volume of 5 cm^3. I discuss our progress over several years of work on this project. We began by building a conventional tabletop clock to use as a test bed while developing several designs of miniature ion-trap vacuum packages, while also developing techniques for various aspects of the clock operation, including ion loading, laser and magnetic field stabilization, and a low power ion trap drive. The ion traps were modeled using boundary element software to assist with the design and parameter optimization of new trap geometries. We expect a novel trap geometry that uses a material new to ion traps to lead to an exceptionally small ion trap vacuum package in the next phase of the project. To achieve the long-term stability required, we have also considered the sensitivity of the clock frequency to magnetic fields. A study of the motion of the individual ions in a room-temperature cloud in the trap was performed with the purpose of understanding the effect of both spatially varying and constant magnetic fields on the clock resonance and therefore the operation of the clock. These effects were studied experimentally and theoretically for several traps. In summary, this dissertation is a contribution to the design, development, and testing of a 171Yb+ ion cloud frequency standard and related techniques, including analyses of trap geometries and parameters, modeling of the ion motion, and the practical operation of the clock.