IEEE Access

A Non-Modulated Triaxial Magnetic Field Compensation Method for Spin-Exchange Relaxation-Free Magnetometer Based on Zero-Field Resonance

Junpeng Zhao, Gang Liu, Jixi Lu, Ke Yang, Danyue Ma, Bozheng Xing, Bangcheng Han, Ming Ding

Published Jan 1, 2019• 20 citations
Publisher

Abstract

In this study, we demonstrate a non-modulated triaxial magnetic field compensation method for spin-exchange relaxation-free (SERF) atomic magnetometers. We realize simultaneous compensation of the magnetic field along the pump and probe directions by maximizing the first order differential value of the zero-field resonance signal. The magnetic field perpendicular to the pump-probe plane is compensated by zeroing the DC response of the magnetometer. The zero-field resonance is obtained by applying a linearly changed magnetic field along the direction perpendicular to that of the pump-probe plane. The first order differential of the zero-field resonance is acquired using the second order central difference method in real time. Compared with the conventional compensation methods, this method does not involve modulation and demodulation. Therefore, it requires no lock-in amplifier, thus making it more applicable in miniature atomic devices. Moreover, this method compensates the magnetic field along the pump and probe directions using only one criterion. It avoids the cross-talk effect between the pump and probe directions in the presence of non-orthogonal coils. The experiment results show that the compensation resolution is 9 pT, 7 pT and 0.05 pT for the probe, pump, and direction perpendicular to the pump-probe plane, respectively.

DOI
10.1109/access.2019.2954103

Related papers

Magnetic Field Compensation for An Optically Pumped Magnetometer Without Iteration

Yaqiong Niu, Chaofeng Ye

The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 29, 2023•1 citation

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•22 citations

In situ measurement of residual magnetic field in SERF atomic magnetometer based on transient response

Di Zhan, Yaoguo Wang, Jixi Lu

Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.

Advanced Sensor Systems and Applications•Nov 20, 2024•0 citations

In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer

Jiancheng Fang, Jie Qin

The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

Review of Scientific Instruments•Oct 1, 2012•69 citations

In Situ Compensation of Triaxial Magnetic Field Gradient for Atomic Magnetometers

Ke Yang, Jixi Lu, Yanning Ma +4 more

Magnetic field gradients affect numerous modern sensitive measurements and physics studies using atomic ensemble, resulting in the loss of coherence. In some cases, the presence of small gradients can reduce the performance significantly. In this study, we propose an effectivein situmethod to compensate the triaxial magnetic field gradient for atomic magnetometers, based on multichannel atomic signals in one vapor cell. We design two novel gradient coils by solving closed-form equations to improve the accuracy and efficiency of compensation. We demonstrate the performance of the compensation method in a spin-exchange relaxation-free atomic magnetometer, which reduces the magnetic linewidth by 4.2%–7.6% under the same conditions at a compensation resolution of 50 pT/cm. The proposed coils generate gradients only along two axes and achieve triaxial decoupling, which compensates for the gradient completely without iteration. Our results may aid in suppressing atomic spin relaxations due to magnetic field gradients in several modern measurements and improve their performance, such as the detection of electric dipole moments, ultralow-field nuclear magnetic resonance, and biomagnetism.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•18 citations

Measurement of Equilibrium Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometers via the Steady-State Response to the Triaxial Magnetic Field

Faming Wang, Xiujie Fang, Bozheng Xing +5 more

This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•7 citations
In this study, we demonstrate a non-modulated triaxial magnetic field compensation method for spin-exchange relaxation-free (SERF) atomic magnetometers. We realize simultaneous compensation of the magnetic field along the pump and probe directions by maximizing the first order differential value of the zero-field resonance signal. The magnetic field perpendicular to the pump-probe plane is compensated by zeroing the DC response of the magnetometer. The zero-field resonance is obtained by applying a linearly changed magnetic field along the direction perpendicular to that of the pump-probe plane. The first order differential of the zero-field resonance is acquired using the second order central difference method in real time. Compared with the conventional compensation methods, this method does not involve modulation and demodulation. Therefore, it requires no lock-in amplifier, thus making it more applicable in miniature atomic devices. Moreover, this method compensates the magnetic field along the pump and probe directions using only one criterion. It avoids the cross-talk effect between the pump and probe directions in the presence of non-orthogonal coils. The experiment results show that the compensation resolution is 9 pT, 7 pT and 0.05 pT for the probe, pump, and direction perpendicular to the pump-probe plane, respectively.
The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.
The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.
Magnetic field gradients affect numerous modern sensitive measurements and physics studies using atomic ensemble, resulting in the loss of coherence. In some cases, the presence of small gradients can reduce the performance significantly. In this study, we propose an effectivein situmethod to compensate the triaxial magnetic field gradient for atomic magnetometers, based on multichannel atomic signals in one vapor cell. We design two novel gradient coils by solving closed-form equations to improve the accuracy and efficiency of compensation. We demonstrate the performance of the compensation method in a spin-exchange relaxation-free atomic magnetometer, which reduces the magnetic linewidth by 4.2%–7.6% under the same conditions at a compensation resolution of 50 pT/cm. The proposed coils generate gradients only along two axes and achieve triaxial decoupling, which compensates for the gradient completely without iteration. Our results may aid in suppressing atomic spin relaxations due to magnetic field gradients in several modern measurements and improve their performance, such as the detection of electric dipole moments, ultralow-field nuclear magnetic resonance, and biomagnetism.
This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.