Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Entropy

Unidimensional Continuous-Variable Quantum Key Distribution with Untrusted Detection under Realistic Conditions

Luyu Huang, Yichen Zhang, Ziyang Chen, Song Yu

Published Nov 11, 2019• 11 citations
Publisher

Abstract

A unidimensional continuous-variable quantum key distribution protocol with untrusted detection is proposed, where the two legitimate partners send unidimensional modulated or Gaussian-modulated coherent states to an untrusted third party, i.e., Charlie, to realize the measurement. Compared with the Gaussian-modulated coherent-state protocols, the unidimensional modulated protocols take the advantage of easy modulation, low cost, and only a small number of random numbers required. Security analysis shows that the proposed protocol cannot just defend all detectors side channels, but also achieve great performance under certain conditions. Specifically, three cases are discussed in detail, including using unidimensional modulated coherent states in Alice’s side, in Bob’s side, and in both sides under realistic conditions, respectively. Under the three conditions, we derive the expressions of the secret key rate and give the optimal gain parameters. It is found that the optimal performance of the protocol is achieved by using unidimensional modulated coherent states in both Alice’s and Bob’s side. The resulting protocol shows the potential for long-distance secure communication using the unidimensional quantum key distribution protocol with simple modulation method and untrusted detection under realistic conditions.

DOI
10.3390/e21111100

Related papers

Continuous-variable measurement-device-independent quantum key distribution using squeezed states

Yichen Zhang, Zhengyu Li, Song Yu +3 more

A continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol using squeezed states is proposed where the two legitimate partners send Gaussian-modulated squeezed states to an untrusted third party to realize the measurement. Security analysis shows that the protocol can not only defend all detector side channels, but also attain higher secret key rates than the coherent-state-based protocol. We also present a method to improve the squeezed-state CV-MDI QKD protocol by adding proper Gaussian noise to the reconciliation side. It is found that there is an optimal added noise to optimize the performance of the protocol in terms of both key rates and maximal transmission distances. The resulting protocol shows the potential of long-distance secure communication using the CV-MDI QKD protocol.

arXiv:1406.0973•Physical Review A•Nov 18, 2014•122 citations

基于压缩态的一维连续变量测量设备无关方案

刘文元 Wen-yuan LIU, 白建东 Jian-dong BAI, 颉琦 Qi JIE +2 more

ObjectiveThe continuous variable quantum key distribution protocol has drawn much attention because of its easy preparation of light source, higher detection efficiency than single photon detector and good compatibility with passive optical communication networks. The measurement device-independent protocol effectively eliminates all known or unknown side-channel attacks in the detection side. However, the initial experiment that encodes information on the amplitude and phase quadratures using coherent or squeezed states, indicated a relatively complexity compared to the unidimensional modulation. The unidimensional continuous variable quantum key distribution protocol has the characteristics of simple modulation process, low cost-effectiveness, and less consumption of random numbers. Realization condition of unidimensional modulation protocol is more convenient than that of two-dimensional Gaussian modulation. For the purpose of simplifying the system and reducing experimental complexity, a novel protocol is proposed, achieving relatively higher security key rate and longer distances.MethodThis paper introduces unidimensional continuous-variable measurement-device-independent quantum key distribution using squeezed states and the security performance of the proposed scheme is comprehensively analyzed including both symmetric and asymmetric transmission distances. For the convenience of analyzing the security of protocol, an entanglement-based (EB) scheme is proposed to provide a comprehensive proof. Based on the measurement device-independent protocol, general coherent state preparation is expanded to the squeezed state. Taking into account the realistic conditions, a detailed comparison investigates the impact of introducing light source noise and detection noise on the protocol's security performance. Furthermore, the impact of squeezing parameter on the performance of the protocol is explored for both asymmetric and symmetric distances. The performance of the protocol is also investigated under the eavesdropper's one mode attack and two mode attack.Results and DiscussionsOur simulation results reveal the existence of optimal modulation variances and squeezing parameters at different transmission distances. These results provide a theoretical framework for achieving optimal secure key rates and secure transmission distances in experimental implementations, thereby facilitating the practical realization of the proposed scheme. Based on these results, we can achieve relatively higher secure key rate by selecting the appropriate parameter for adapting different application scenarios. This could pave the way for greater cost-effectiveness and a simpler way to implement the protocol in the future. As theoretical analysis mentioned about imperfect source and detectors, it may be insufficient to guarantee the realistic implement. It is possible that these imperfections can be compensated by optical phase-sensitive amplifiers.ConclusionThis paper presents a protocol for unidimensional continuous-variable measurement-device-independent quantum key distribution using squeezed state. By adjusting the modulation variance and squeezed parameter, we can achieve more efficient and longer transmission distances while ensuring the actual security performance of the system. This research also clarifies that the influencing mechanism of source noise and detected noise on the performance of the protocol. We can selectively tune the modulation variance and squeezed parameter towards different application scenarios.

Acta Sinica Quantum Optica•Jan 1, 2024•0 citations

Unidimensional continuous-variable quantum key distribution

Vladyslav C. Usenko, Frédéric Grosshans

We propose the continuous-variable quantum key distribution protocol based on the Gaussian modulation of a single quadrature of the coherent states of light, which is aimed to provide simplified implementation compared to the symmetrically modulated Gaussian coherent-state protocols. The protocol waives the necessity in one of the quadrature modulations and the corresponding channel transmittance estimation. The security of the protocol against collective attacks in a generally phase-sensitive Gaussian channel is analyzed and is shown achievable upon certain conditions. Robustness of the protocol to channel imperfections is compared to that of the symmetrical coherent-state protocol. The simplified unidimensional protocol is shown possible at a reasonable quantitative cost in terms of key rate and of tolerable channel excess noise.

arXiv:1504.07093•Physical Review A•Dec 28, 2015•134 citations

Measurement-device-independent quantum key distribution using unidimensional Gaussian-modulated coherent states

Luyu Huang, Yichen Zhang, Ziyang Chen +2 more

We report a measurement-device-independent quantum key distribution protocol using unidimensional Gaussian-modulated coherent states in both sides, which shows the potential of long-distance secure communication with simple modulation method.

Frontiers in Optics•Jan 1, 2019•0 citations

Experimental Demonstration of Free-Space Unidimensional Continuous-Variable Quantum Key Distribution Under High Detector Noise

Rachita Nandan, Jayanth Ramakrishnan, Shashi Prabhakar +1 more

Continuous-variable quantum key distribution (CV-QKD), which uses quadratures of the electromagnetic field, enables practical quantum communication using standard telecommunication technologies. Unidimensional CV-QKD (UD-CVQKD) simplifies the implementation by restricting modulation to a single quadrature. In this work, we experimentally demonstrate a free-space Gaussian-modulated UD-CVQKD system operating under a high detector electronic-noise regime (1.4 shot-noise units). The system employs polarized coherent states with signal and local oscillator co-propagating in the same spatial mode in orthogonal polarizations, ensuring stable interference. System security is analyzed under both untrusted (UTD) and trusted (TD) detector noise models. While no positive secret key rate is obtained under the UTD model, the TD model enables secure key generation over a finite range of modulation variances, highlighting the critical role of detector trust in high-noise conditions. A maximum secret key rate of 270 kbps is achieved at an optimal modulation variance of 11.57. Furthermore, secure operation requires high-transmittance (low-loss) channels under such noise conditions. This study demonstrates the practical feasibility of free-space UD-CVQKD in realistic high electronic-noise detection constraints and highlights detector electronic noise as a key limiting factor in practical systems.

quant-pharXiv:2606.07206•Jun 8, 2026•1 citation

Continuous-variable measurement-device-independent quantum key distribution

Zhengyu Li, Yichen Zhang, Feihu Xu +2 more

We propose a continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, in which detection is conducted by an untrusted third party. Our protocol can defend all detector side channels, which seriously threaten the security of a practical CV QKD system. Its security analysis against arbitrary collective attacks is derived based on the fact that the entanglement-based scheme of CV-MDI QKD is equivalent to the conventional CV QKD with coherent states and heterodyne detection. We find that the maximal total transmission distance is achieved by setting the untrusted third party close to one of the legitimate users. Furthermore, an alternate detection scheme, a special application of CV-MDI QKD, is proposed to enhance the security of the standard CV QKD system.

arXiv:1312.4655•Physical Review A•May 7, 2014•230 citations
A unidimensional continuous-variable quantum key distribution protocol with untrusted detection is proposed, where the two legitimate partners send unidimensional modulated or Gaussian-modulated coherent states to an untrusted third party, i.e., Charlie, to realize the measurement. Compared with the Gaussian-modulated coherent-state protocols, the unidimensional modulated protocols take the advantage of easy modulation, low cost, and only a small number of random numbers required. Security analysis shows that the proposed protocol cannot just defend all detectors side channels, but also achieve great performance under certain conditions. Specifically, three cases are discussed in detail, including using unidimensional modulated coherent states in Alice’s side, in Bob’s side, and in both sides under realistic conditions, respectively. Under the three conditions, we derive the expressions of the secret key rate and give the optimal gain parameters. It is found that the optimal performance of the protocol is achieved by using unidimensional modulated coherent states in both Alice’s and Bob’s side. The resulting protocol shows the potential for long-distance secure communication using the unidimensional quantum key distribution protocol with simple modulation method and untrusted detection under realistic conditions.
A continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol using squeezed states is proposed where the two legitimate partners send Gaussian-modulated squeezed states to an untrusted third party to realize the measurement. Security analysis shows that the protocol can not only defend all detector side channels, but also attain higher secret key rates than the coherent-state-based protocol. We also present a method to improve the squeezed-state CV-MDI QKD protocol by adding proper Gaussian noise to the reconciliation side. It is found that there is an optimal added noise to optimize the performance of the protocol in terms of both key rates and maximal transmission distances. The resulting protocol shows the potential of long-distance secure communication using the CV-MDI QKD protocol.
ObjectiveThe continuous variable quantum key distribution protocol has drawn much attention because of its easy preparation of light source, higher detection efficiency than single photon detector and good compatibility with passive optical communication networks. The measurement device-independent protocol effectively eliminates all known or unknown side-channel attacks in the detection side. However, the initial experiment that encodes information on the amplitude and phase quadratures using coherent or squeezed states, indicated a relatively complexity compared to the unidimensional modulation. The unidimensional continuous variable quantum key distribution protocol has the characteristics of simple modulation process, low cost-effectiveness, and less consumption of random numbers. Realization condition of unidimensional modulation protocol is more convenient than that of two-dimensional Gaussian modulation. For the purpose of simplifying the system and reducing experimental complexity, a novel protocol is proposed, achieving relatively higher security key rate and longer distances.MethodThis paper introduces unidimensional continuous-variable measurement-device-independent quantum key distribution using squeezed states and the security performance of the proposed scheme is comprehensively analyzed including both symmetric and asymmetric transmission distances. For the convenience of analyzing the security of protocol, an entanglement-based (EB) scheme is proposed to provide a comprehensive proof. Based on the measurement device-independent protocol, general coherent state preparation is expanded to the squeezed state. Taking into account the realistic conditions, a detailed comparison investigates the impact of introducing light source noise and detection noise on the protocol's security performance. Furthermore, the impact of squeezing parameter on the performance of the protocol is explored for both asymmetric and symmetric distances. The performance of the protocol is also investigated under the eavesdropper's one mode attack and two mode attack.Results and DiscussionsOur simulation results reveal the existence of optimal modulation variances and squeezing parameters at different transmission distances. These results provide a theoretical framework for achieving optimal secure key rates and secure transmission distances in experimental implementations, thereby facilitating the practical realization of the proposed scheme. Based on these results, we can achieve relatively higher secure key rate by selecting the appropriate parameter for adapting different application scenarios. This could pave the way for greater cost-effectiveness and a simpler way to implement the protocol in the future. As theoretical analysis mentioned about imperfect source and detectors, it may be insufficient to guarantee the realistic implement. It is possible that these imperfections can be compensated by optical phase-sensitive amplifiers.ConclusionThis paper presents a protocol for unidimensional continuous-variable measurement-device-independent quantum key distribution using squeezed state. By adjusting the modulation variance and squeezed parameter, we can achieve more efficient and longer transmission distances while ensuring the actual security performance of the system. This research also clarifies that the influencing mechanism of source noise and detected noise on the performance of the protocol. We can selectively tune the modulation variance and squeezed parameter towards different application scenarios.
We propose the continuous-variable quantum key distribution protocol based on the Gaussian modulation of a single quadrature of the coherent states of light, which is aimed to provide simplified implementation compared to the symmetrically modulated Gaussian coherent-state protocols. The protocol waives the necessity in one of the quadrature modulations and the corresponding channel transmittance estimation. The security of the protocol against collective attacks in a generally phase-sensitive Gaussian channel is analyzed and is shown achievable upon certain conditions. Robustness of the protocol to channel imperfections is compared to that of the symmetrical coherent-state protocol. The simplified unidimensional protocol is shown possible at a reasonable quantitative cost in terms of key rate and of tolerable channel excess noise.
Continuous-variable quantum key distribution (CV-QKD), which uses quadratures of the electromagnetic field, enables practical quantum communication using standard telecommunication technologies. Unidimensional CV-QKD (UD-CVQKD) simplifies the implementation by restricting modulation to a single quadrature. In this work, we experimentally demonstrate a free-space Gaussian-modulated UD-CVQKD system operating under a high detector electronic-noise regime (1.4 shot-noise units). The system employs polarized coherent states with signal and local oscillator co-propagating in the same spatial mode in orthogonal polarizations, ensuring stable interference. System security is analyzed under both untrusted (UTD) and trusted (TD) detector noise models. While no positive secret key rate is obtained under the UTD model, the TD model enables secure key generation over a finite range of modulation variances, highlighting the critical role of detector trust in high-noise conditions. A maximum secret key rate of 270 kbps is achieved at an optimal modulation variance of 11.57. Furthermore, secure operation requires high-transmittance (low-loss) channels under such noise conditions. This study demonstrates the practical feasibility of free-space UD-CVQKD in realistic high electronic-noise detection constraints and highlights detector electronic noise as a key limiting factor in practical systems.
We propose a continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, in which detection is conducted by an untrusted third party. Our protocol can defend all detector side channels, which seriously threaten the security of a practical CV QKD system. Its security analysis against arbitrary collective attacks is derived based on the fact that the entanglement-based scheme of CV-MDI QKD is equivalent to the conventional CV QKD with coherent states and heterodyne detection. We find that the maximal total transmission distance is achieved by setting the untrusted third party close to one of the legitimate users. Furthermore, an alternate detection scheme, a special application of CV-MDI QKD, is proposed to enhance the security of the standard CV QKD system.