Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

A Modified Spin Pulsed Readout Method for NV Center Ensembles Reducing Optical Noise

Jixing Zhang, Heng Yuan, Ning Zhang, Lixia Xu, Guodong Bian, Pengcheng Fan, Mingxin Li, Zhi Xin Zhan, Kan Yu

Published Oct 29, 2019• 25 citations
Publisher

Abstract

The optical-noise-limited spin readout sensitivity determines the precision of quantum measurement based on nitrogen-vacancy (NV) center. This article investigates the fluorescence dynamics of NV centers by solving the optical rate equations and obtains complete theoretical formulas for the existing optical spin readout method. A transfer coefficient of optical noise to signal noise in the existing differential methods at different frequencies is introduced so as to analyze the optical noise suppression ability and the signal-to-noise ratio (SNR) results under the influence of photon shot noise and optical noise. To further reduce the influence of optical noise on the signal, we propose a modified method to minimize the transfer coefficient by adding a first-order compensation term. Compared with conventional methods, our modified method showed a twofold optical noise suppression ability improvement in the measurement frequency bandwidth. The experiment proves that the final SNR is increased by 43.4% for a long-term measurement. This modified method should lead to immediate improvements in pulsed spin readout of NV center ensembles without extra instrumentation for applications in magnetic field, electric field, and temperature measurements.

DOI
10.1109/tim.2019.2949321

Related papers

A pulsed time-varying method for improving the spin readout efficiency of nitrogen vacancy centers

Tianzheng Liu, Jixing Zhang, Heng Yuan +8 more

Abstract In this work, a time-varying pulse waveform spin readout sequence method is proposed to improve the spin readout efficiency of nitrogen-vacancy (NV) centers. The method consists of performing the readout signal-to-noise ratio (SNR) analysis via the construction of a rate equation model of the NV center. We demonstrate a superior performance from the time-varying waveform readout approach and focus on the role of the readout optimization in quantum measurements. A detailed comparison of the readout SNR of the time-varying waveform and conventional waveform is provided. We experimentally demonstrate that the readout SNR is increased by 8% by utilizing an optimized waveform. It is anticipated that the improved method will effectively benefit the sensing capability of NV center ensembles and provide support for high-precision measurements of solid systems.

Journal of Physics D Applied Physics•Jul 6, 2021•5 citations

An improved spin readout for nitrogen vacancy center ensemble based on a maximum likelihood estimation method

Jixing Zhang, Lixia Xu, Tao Shi +7 more

Abstract In this work, a spin readout method using fluorescence dynamics is proposed based on maximum likelihood estimation (MLE) for improving the pulsed spin readout accuracy of nitrogen vacancy (NV) center. This estimation method can saturate the Cramér–Rao bound and enhance the photon-shot-noise-limited spin readout accuracy by 20% compared with conventional photon summation method. By employing a rate equation model of the NV center, the exact solution for the fluorescence dynamics is obtained. Additionally, according to the rate equation model’s relationship with fluorescence dynamics, spin, and pumping light power, a practical MLE readout scheme is furnished, which is able to distinguish spin readout information and classical noise. Compared with the conventional method, the classical noise suppression capability can be improved by 300 times. It is anticipated that the MLE method will effectively benefit sensing capability based on the NV centers even other scalable defect complexes in solid systems.

Journal of Physics D Applied Physics•Jul 21, 2020•14 citations

Impact of Photoelectric Readout Noise on Magnetic Field Sensitivity of NV Centers in Diamond

Ilia Chuprina, Genko Genov, Christoph Findler +3 more

Nitrogen-vacancy (NV) centers in diamond are of great interest for nano- and macro-scale magnetic field sensing. Most sensing protocols rely on conventional optical readout, which is limited by photon shot noise. The recently developed photoelectrical (PE) readout of the NV center electron spin state promises to overcome these limitations. However, the noise of the PE readout and its influence on readout efficiency have not been thoroughly studied. In this work, we perform magnetic field sensing and estimate the sensitivity using optical and PE readout with a single and an ensemble of NV centers in diamond. We investigate the electronic noise associated with the photoelectric detection and estimate the readout efficiency, using Gaussian statistics. Our quantitative analysis shows that the Johnson-Nyquist noise-limited photoelectric magnetic field sensitivity could outperform optical measurements by an order of magnitude. This work is an essential step towards the development of on-chip magnetometers using photoelectrical detection in diamond.

cond-mat.mes-hallCross-listedarXiv:2604.20901•Apr 22, 2026•0 citations

Online optimization for optical readout of a single electron spin in diamond

Xue Lin, Jingwei Fan, Runchuan Ye +4 more

The nitrogen-vacancy (NV) center in diamond has been developed as a promising platform for quantum sensing, especially for magnetic field measurements in the nano-tesla range with a nano-meter resolution. Optical spin readout performance has a direct effect on the signal-to-noise ratio (SNR) of experiments. In this work, we introduce an online optimization method to customize the laser waveform for readout. Both simulations and experiments reveal that our new scheme optimizes the optically detected magnetic resonance in NV center. The SNR of optical spin readout has been witnessed a 44.1% increase in experiments. In addition, we applied the scheme to the Rabi oscillation experiment, which shows an improvement of 46.0% in contrast and a reduction of 12.1% in mean deviation compared to traditional constant laser power SNR optimization. This scheme is promising to improve sensitivities for a wide range of NV-based applications in the future.

arXiv:2212.09214•Frontiers of Physics•Jan 12, 2023•7 citations

Purcell and Pulse Induced Impact for Measurement Based on Nitrogen-Vacancy Centers in Diamond

Lu Min Ji, Li Ye Zhao, Yu Hai Wang

Nitrogen-vacancy (NV) color centers in diamond serve as promising atomic spin systems for measurement applications requiring high accuracy and sensitivity. A key challenge in NV-based quantum sensing is minimizing spin readout noise to approach the standard quantum limit (SQL). Based on a six-level model, this work analyze the dependence of NV-based quantum sensing performance, including spin state readout noise and signal-to-noise ratio (SNR), on controllable parameters such as the Purcell factor and excitation laser pulse characteristics. This study demonstrates that a shorter excitation pulse duration results in a higher saturation value of ground-state spin polarization, while the total time required for the polarization process remains constant. Additionally, the spin readout noise does not improve monotonically with decreasing excitation pulse duration; instead, it initially decreases and subsequently increases as the pulse duration varies. The spin readout noise reaches its optimal level when the pulse duration is 3 ns. Furthermore, no positive correlation exists between the signal-to-noise ratio (SNR) and the Purcell factor, and there is also an optimal value for SNR. When the pulse duration ranges from 1 ns to 40 ns, the variation in SNR is relatively insignificant. This research offers a novel perspective for enhancing the performance of quantum sensing based on diamond defects, such as nitrogen-vacancy (NV) centers.

Key engineering materials•Nov 25, 2025•0 citations

Temporal filtered quantum sensing with the nitrogen-vacancy center in diamond

Florian Boehm, Yan Liu, Chengliang Yue +5 more

Nitrogen vacancy centers in diamond are among the leading solid state quantum platforms, offering exceptional spatial resolution and sensitivity for applications such as magnetic field sensing, thermometry, and bioimaging. However, in high background environments,such as those encountered in in vitro diagnostics, the performance of NV based sensors can be compromised by strong background fluorescence, particularly from substrates such as nitrocellulose. In this work, we analytically and experimentally investigate the use of pulsed laser excitation combined with time gating techniques to suppress background fluorescence and enhance the signal to noise ratio in NV based quantum sensing, with an emphasis on spin enhanced biosensing. Through experimental studies using mixed ensembles of silicon vacancy and NV centers in bulk diamond, as well as fluorescent nanodiamonds on NC substrates, we demonstrate significant improvements in NV spin resonance visibility, demonstrated by an increase of the SNR by up to 4x, and a resulting measurement time reduction by 16x. The presented technique and results here can help significantly increase the readout efficiency and speed in future applications of NV centers in high background environments, such as in IVD, where the NV centers are used as a fluorescent label for biomolecules.

quant-pharXiv:2511.02369•Nov 5, 2025
The optical-noise-limited spin readout sensitivity determines the precision of quantum measurement based on nitrogen-vacancy (NV) center. This article investigates the fluorescence dynamics of NV centers by solving the optical rate equations and obtains complete theoretical formulas for the existing optical spin readout method. A transfer coefficient of optical noise to signal noise in the existing differential methods at different frequencies is introduced so as to analyze the optical noise suppression ability and the signal-to-noise ratio (SNR) results under the influence of photon shot noise and optical noise. To further reduce the influence of optical noise on the signal, we propose a modified method to minimize the transfer coefficient by adding a first-order compensation term. Compared with conventional methods, our modified method showed a twofold optical noise suppression ability improvement in the measurement frequency bandwidth. The experiment proves that the final SNR is increased by 43.4% for a long-term measurement. This modified method should lead to immediate improvements in pulsed spin readout of NV center ensembles without extra instrumentation for applications in magnetic field, electric field, and temperature measurements.
Abstract In this work, a time-varying pulse waveform spin readout sequence method is proposed to improve the spin readout efficiency of nitrogen-vacancy (NV) centers. The method consists of performing the readout signal-to-noise ratio (SNR) analysis via the construction of a rate equation model of the NV center. We demonstrate a superior performance from the time-varying waveform readout approach and focus on the role of the readout optimization in quantum measurements. A detailed comparison of the readout SNR of the time-varying waveform and conventional waveform is provided. We experimentally demonstrate that the readout SNR is increased by 8% by utilizing an optimized waveform. It is anticipated that the improved method will effectively benefit the sensing capability of NV center ensembles and provide support for high-precision measurements of solid systems.
Abstract In this work, a spin readout method using fluorescence dynamics is proposed based on maximum likelihood estimation (MLE) for improving the pulsed spin readout accuracy of nitrogen vacancy (NV) center. This estimation method can saturate the Cramér–Rao bound and enhance the photon-shot-noise-limited spin readout accuracy by 20% compared with conventional photon summation method. By employing a rate equation model of the NV center, the exact solution for the fluorescence dynamics is obtained. Additionally, according to the rate equation model’s relationship with fluorescence dynamics, spin, and pumping light power, a practical MLE readout scheme is furnished, which is able to distinguish spin readout information and classical noise. Compared with the conventional method, the classical noise suppression capability can be improved by 300 times. It is anticipated that the MLE method will effectively benefit sensing capability based on the NV centers even other scalable defect complexes in solid systems.
Nitrogen-vacancy (NV) centers in diamond are of great interest for nano- and macro-scale magnetic field sensing. Most sensing protocols rely on conventional optical readout, which is limited by photon shot noise. The recently developed photoelectrical (PE) readout of the NV center electron spin state promises to overcome these limitations. However, the noise of the PE readout and its influence on readout efficiency have not been thoroughly studied. In this work, we perform magnetic field sensing and estimate the sensitivity using optical and PE readout with a single and an ensemble of NV centers in diamond. We investigate the electronic noise associated with the photoelectric detection and estimate the readout efficiency, using Gaussian statistics. Our quantitative analysis shows that the Johnson-Nyquist noise-limited photoelectric magnetic field sensitivity could outperform optical measurements by an order of magnitude. This work is an essential step towards the development of on-chip magnetometers using photoelectrical detection in diamond.
The nitrogen-vacancy (NV) center in diamond has been developed as a promising platform for quantum sensing, especially for magnetic field measurements in the nano-tesla range with a nano-meter resolution. Optical spin readout performance has a direct effect on the signal-to-noise ratio (SNR) of experiments. In this work, we introduce an online optimization method to customize the laser waveform for readout. Both simulations and experiments reveal that our new scheme optimizes the optically detected magnetic resonance in NV center. The SNR of optical spin readout has been witnessed a 44.1% increase in experiments. In addition, we applied the scheme to the Rabi oscillation experiment, which shows an improvement of 46.0% in contrast and a reduction of 12.1% in mean deviation compared to traditional constant laser power SNR optimization. This scheme is promising to improve sensitivities for a wide range of NV-based applications in the future.
Nitrogen-vacancy (NV) color centers in diamond serve as promising atomic spin systems for measurement applications requiring high accuracy and sensitivity. A key challenge in NV-based quantum sensing is minimizing spin readout noise to approach the standard quantum limit (SQL). Based on a six-level model, this work analyze the dependence of NV-based quantum sensing performance, including spin state readout noise and signal-to-noise ratio (SNR), on controllable parameters such as the Purcell factor and excitation laser pulse characteristics. This study demonstrates that a shorter excitation pulse duration results in a higher saturation value of ground-state spin polarization, while the total time required for the polarization process remains constant. Additionally, the spin readout noise does not improve monotonically with decreasing excitation pulse duration; instead, it initially decreases and subsequently increases as the pulse duration varies. The spin readout noise reaches its optimal level when the pulse duration is 3 ns. Furthermore, no positive correlation exists between the signal-to-noise ratio (SNR) and the Purcell factor, and there is also an optimal value for SNR. When the pulse duration ranges from 1 ns to 40 ns, the variation in SNR is relatively insignificant. This research offers a novel perspective for enhancing the performance of quantum sensing based on diamond defects, such as nitrogen-vacancy (NV) centers.
Nitrogen vacancy centers in diamond are among the leading solid state quantum platforms, offering exceptional spatial resolution and sensitivity for applications such as magnetic field sensing, thermometry, and bioimaging. However, in high background environments,such as those encountered in in vitro diagnostics, the performance of NV based sensors can be compromised by strong background fluorescence, particularly from substrates such as nitrocellulose. In this work, we analytically and experimentally investigate the use of pulsed laser excitation combined with time gating techniques to suppress background fluorescence and enhance the signal to noise ratio in NV based quantum sensing, with an emphasis on spin enhanced biosensing. Through experimental studies using mixed ensembles of silicon vacancy and NV centers in bulk diamond, as well as fluorescent nanodiamonds on NC substrates, we demonstrate significant improvements in NV spin resonance visibility, demonstrated by an increase of the SNR by up to 4x, and a resulting measurement time reduction by 16x. The presented technique and results here can help significantly increase the readout efficiency and speed in future applications of NV centers in high background environments, such as in IVD, where the NV centers are used as a fluorescent label for biomolecules.