Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Linewidth dependence of NbN-based microwave kinetic inductance detectors

Shun Negishi, Hikaru Mikami, S Hashimoto, Kensuke Nakajima, Hirotaka Terai, Saburo Tanaka, Seiichiro Ariyoshi

Published Sep 1, 2019• 0 citations
Publisher

Abstract

We analysed, fabricated, and characterised niobium nitride (NbN)-based microwave kinetic inductance detectors (MKIDs) with a rewound strip structure (spiral-MKIDs). To control resonance characteristics precisely, the linewidth ( w ) dependence of rewound spiral resonators varying between w = 10, 20, and 40 μm was analysed using an electromagnetic field simulator; the resonance frequencies ( f 0 's) were obtained as 4.42, 4.58, and 5.15 GHz respectively, proving that the inductance decreases as the w increases. To verify the simulation results experimentally, NbN-based MKID arrays with different linewidths were fabricated on 10 × 10 mm 2 sapphire substrates, and cooled down to 3 K. The microwave characteristics with a vector network analyser, and f 0 's were found to be 4.11, 4.23, and 4.85 GHz for the MKIDs with w = 10, 20, and 40 μm, respectively. These values are in agreement with the simulation results within 7.6% accuracy. The other resonance characteristics such as the scattering-matrix element ( S 21 ) and loaded quality factor ( Q L ) showed the similar w dependence with the simulation. Spiral-MKIDs with narrower w is expected to have better detector performance owing to shallower S 21 and higher Q L .

DOI
10.1088/1742-6596/1293/1/012048

Related papers

Design and Fabrication of Microwave Kinetic Inductance Detectors using NbN Symmetric Spiral Resonator Array

Kei Hayashi, Atsushi SAITO, Yasunobu Ogawa +9 more

We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.

Journal of Physics Conference Series•May 12, 2014•9 citations

Evaluation of YBa2Cu3O7-δ-based microwave kinetic inductance detectors with rewound spiral resonators

Kaoru Sato, Seiichiro Ariyoshi, Shun Negishi +4 more

We propose a YBCO-based microwave kinetic inductance detector with rewound strip structure (spiral-MKID) suitable for imaging applications. The superconducting rewound strip acts as a microwave resonator and broadband antenna. A 25-pixel MKID array with a width of 10 μm and slightly varying length of each of the resonators was fabricated on a 10 × 10 mm 2 -MgO substrate. Microwave resonance characteristics of the array were evaluated by measuring one of the scattering-matrix elements, S 21 , using a vector network analyser. The 25 resonance dips were clearly observed around 5 GHz; the frequency spacing between adjacent pixels was 13 MHz, with a standard deviation of 5 MHz. Each resonance frequency was shifted by 170 MHz, owing to the temperature change from 11 K to 50 K. We showed that the YBCO-based spiral-MKIDs with 200 nm-thick films have loaded quality factors of 1,200 at 11 K and 700 at 50 K. We irradiated visible light to a single pixel on the array. The obtained noise equivalent power was on the order of 10 −9 W/Hz 1/2 , while the response time was smaller than 30 ms at 13 K. The responsivity of the array at 70 K was six times larger than that at 13 K.

Journal of Physics Conference Series•Jul 1, 2018•6 citations

Relationship Between Loaded Quality Factor and Responsivity for NbN-Based MKIDs Using Dual-Function Spiral Strip

Atsushi SAITO, Kensuke Nakajima, Kei Hayashi +9 more

We investigated the relationship between loaded quality factor (QL) and responsivity of microwave kinetic inductance detectors (MKIDs) using a dual-function spiral strip (DFSS). Three types of DFSSs with different QL values were designed, and the S21properties were simulated when kinetic inductance of a superconductor was changed by using a 2.5-dimentional simulator. The simulated results showed that a very high QLvalue was not necessarily required. The resonator frequencies of the 25-MKID array using a better type of DFSS (QL~ 3500) were adjusted to be separated by 5 MHz around 2.0 GHz. The 25-MKID array were fabricated using 20-nm thick niobium nitride films deposited on r-plane sapphire substrates. We clearly observed 25 half-wavelength resonances around 2.0 GHz at 2.245 K. The optical responses were also confirmed using hot and cold radiation. The dependence of the responsivity on the QLindicated that the QLvalue of approximately 2000 could obtain higher responsivity.

IEEE Transactions on Applied Superconductivity•Nov 6, 2014•3 citations

Terahertz response of NbN-based microwave kinetic inductance detectors with rewound spiral resonator

Seiichiro Ariyoshi, Kensuke Nakajima, Atsushi SAITO +6 more

Abstract We have developed microwave kinetic inductance detectors (MKIDs) consisting of dual-purpose rewound spirals (spiral-MKIDs) made of a metal nitride superconductor for terahertz imaging applications. An NbN-based spiral-MKID array with 25 pixels was fabricated, and the fundamental performance of the terahertz receptivity was evaluated at the equilibrium temperature of a conventional 4 He refrigerator (≃3 K). The microwave transmission property of the array showed the 25 resonance lines, equally separated by frequency, in the microwave range from 2.70 to 2.95 GHz. To evaluate its optical performance as a terahertz detector, we measured the spiral-MKID’s spectral response, response time, and noise equivalent power (NEP), and confirmed that it revealed a broad spectral response from 1 to 9 THz and an effective response time of approximately 80 μ s. The noise-equivalent power was estimated to be .

Superconductor Science and Technology•Feb 2, 2016•8 citations

Design evaluation of microwave transmission properties of YBa2Cu3O7-based kinetic inductance detectors

Seiichiro Ariyoshi, Hikaru Mikami, Atsushi Ebata +4 more

Abstract We designed, fabricated, and characterized microwave transmission properties with rewound strip structures for YBa2Cu3O7 (YBCO)-based kinetic inductance detectors (KIDs). The superconducting rewound strip serves as a microwave resonator and as a broadband terahertz-wave antenna. To predict the microwave resonance characteristics before fabrication, the line-width (w) and space (s) dependence of the spiral resonators were analyzed using an electromagnetic simulator; the resonance frequency increased, and the quality factor decreased with increasing w and s from 10 to 40 μm. YBCO-based KID arrays with different w (10 and 40 μm) were fabricated on 10 mm-square MgO substrates, cooled to 3 K using a 4He refrigerator, and evaluated using a vector network analyzer to verify the result of the simulation experimentally. The measured resonance frequency ratio of 1.11 times (5.04 → 5.59 GHz) agreed with the simulated ones of 1.10 times (4.84 → 5.33 GHz) between w = 10 and 40 μm. The other resonance characteristics, such as transmission coefficient and quality factor, have a similar w dependence with the simulation.

Materials Research Express•Nov 1, 2021•1 citation

Microwave Characteristics of Microwave Kinetic Inductance Detectors Using Rewound Spiral Resonators Array

Kei Hayashi, Atsushi SAITO, Taisuke Sawada +5 more

We investigated microwave characteristics of microwave kinetic inductance detectors (MKIDs) using rewound spiral resonators called as spiral-MKIDs. To realize 25-array spiral-MKIDs, frequency characteristics of 25 resonators with different resonant frequencies should be equal. We proposed spiral-MKIDs with expanded and contracted symmetric spiral resonator. We conducted simulations for 25 arrays and obtained maximum return losses of over 12 dB and unloaded quality factors of over 230,000 for frequencies between 3.2 and 3.4 GHz. This symmetric resonator may be useful for realization of large array MKIDs.

Physics Procedia•Jan 1, 2013•6 citations
We analysed, fabricated, and characterised niobium nitride (NbN)-based microwave kinetic inductance detectors (MKIDs) with a rewound strip structure (spiral-MKIDs). To control resonance characteristics precisely, the linewidth ( w ) dependence of rewound spiral resonators varying between w = 10, 20, and 40 μm was analysed using an electromagnetic field simulator; the resonance frequencies ( f 0 's) were obtained as 4.42, 4.58, and 5.15 GHz respectively, proving that the inductance decreases as the w increases. To verify the simulation results experimentally, NbN-based MKID arrays with different linewidths were fabricated on 10 × 10 mm 2 sapphire substrates, and cooled down to 3 K. The microwave characteristics with a vector network analyser, and f 0 's were found to be 4.11, 4.23, and 4.85 GHz for the MKIDs with w = 10, 20, and 40 μm, respectively. These values are in agreement with the simulation results within 7.6% accuracy. The other resonance characteristics such as the scattering-matrix element ( S 21 ) and loaded quality factor ( Q L ) showed the similar w dependence with the simulation. Spiral-MKIDs with narrower w is expected to have better detector performance owing to shallower S 21 and higher Q L .
We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.
We propose a YBCO-based microwave kinetic inductance detector with rewound strip structure (spiral-MKID) suitable for imaging applications. The superconducting rewound strip acts as a microwave resonator and broadband antenna. A 25-pixel MKID array with a width of 10 μm and slightly varying length of each of the resonators was fabricated on a 10 × 10 mm 2 -MgO substrate. Microwave resonance characteristics of the array were evaluated by measuring one of the scattering-matrix elements, S 21 , using a vector network analyser. The 25 resonance dips were clearly observed around 5 GHz; the frequency spacing between adjacent pixels was 13 MHz, with a standard deviation of 5 MHz. Each resonance frequency was shifted by 170 MHz, owing to the temperature change from 11 K to 50 K. We showed that the YBCO-based spiral-MKIDs with 200 nm-thick films have loaded quality factors of 1,200 at 11 K and 700 at 50 K. We irradiated visible light to a single pixel on the array. The obtained noise equivalent power was on the order of 10 −9 W/Hz 1/2 , while the response time was smaller than 30 ms at 13 K. The responsivity of the array at 70 K was six times larger than that at 13 K.
We investigated the relationship between loaded quality factor (QL) and responsivity of microwave kinetic inductance detectors (MKIDs) using a dual-function spiral strip (DFSS). Three types of DFSSs with different QL values were designed, and the S21properties were simulated when kinetic inductance of a superconductor was changed by using a 2.5-dimentional simulator. The simulated results showed that a very high QLvalue was not necessarily required. The resonator frequencies of the 25-MKID array using a better type of DFSS (QL~ 3500) were adjusted to be separated by 5 MHz around 2.0 GHz. The 25-MKID array were fabricated using 20-nm thick niobium nitride films deposited on r-plane sapphire substrates. We clearly observed 25 half-wavelength resonances around 2.0 GHz at 2.245 K. The optical responses were also confirmed using hot and cold radiation. The dependence of the responsivity on the QLindicated that the QLvalue of approximately 2000 could obtain higher responsivity.
Abstract We have developed microwave kinetic inductance detectors (MKIDs) consisting of dual-purpose rewound spirals (spiral-MKIDs) made of a metal nitride superconductor for terahertz imaging applications. An NbN-based spiral-MKID array with 25 pixels was fabricated, and the fundamental performance of the terahertz receptivity was evaluated at the equilibrium temperature of a conventional 4 He refrigerator (≃3 K). The microwave transmission property of the array showed the 25 resonance lines, equally separated by frequency, in the microwave range from 2.70 to 2.95 GHz. To evaluate its optical performance as a terahertz detector, we measured the spiral-MKID’s spectral response, response time, and noise equivalent power (NEP), and confirmed that it revealed a broad spectral response from 1 to 9 THz and an effective response time of approximately 80 μ s. The noise-equivalent power was estimated to be .
Abstract We designed, fabricated, and characterized microwave transmission properties with rewound strip structures for YBa2Cu3O7 (YBCO)-based kinetic inductance detectors (KIDs). The superconducting rewound strip serves as a microwave resonator and as a broadband terahertz-wave antenna. To predict the microwave resonance characteristics before fabrication, the line-width (w) and space (s) dependence of the spiral resonators were analyzed using an electromagnetic simulator; the resonance frequency increased, and the quality factor decreased with increasing w and s from 10 to 40 μm. YBCO-based KID arrays with different w (10 and 40 μm) were fabricated on 10 mm-square MgO substrates, cooled to 3 K using a 4He refrigerator, and evaluated using a vector network analyzer to verify the result of the simulation experimentally. The measured resonance frequency ratio of 1.11 times (5.04 → 5.59 GHz) agreed with the simulated ones of 1.10 times (4.84 → 5.33 GHz) between w = 10 and 40 μm. The other resonance characteristics, such as transmission coefficient and quality factor, have a similar w dependence with the simulation.
We investigated microwave characteristics of microwave kinetic inductance detectors (MKIDs) using rewound spiral resonators called as spiral-MKIDs. To realize 25-array spiral-MKIDs, frequency characteristics of 25 resonators with different resonant frequencies should be equal. We proposed spiral-MKIDs with expanded and contracted symmetric spiral resonator. We conducted simulations for 25 arrays and obtained maximum return losses of over 12 dB and unloaded quality factors of over 230,000 for frequencies between 3.2 and 3.4 GHz. This symmetric resonator may be useful for realization of large array MKIDs.