Abstract We developed a phase-sensitive sensor based on the optical weak measurement for label-free detection of biomolecular interaction. The weak value amplification system can be implemented in common-path with total internal reflection structure. The phase difference between p and s polarizations caused by biomolecular recognition is measured by the central wavelength shift of the frequency domain weak measurement system. Structure of p and s polarizations in common-path makes system robust and stable. The applicability is illustrated by real-time monitoring interaction of biomolecules.
Abstract We developed a phase-sensitive sensor based on the optical weak measurement for label-free detection of biomolecular interaction. The weak value amplification system can be implemented in common-path with total internal reflection structure. The phase difference between p and s polarizations caused by biomolecular recognition is measured by the central wavelength shift of the frequency domain weak measurement system. Structure of p and s polarizations in common-path makes system robust and stable. The applicability is illustrated by real-time monitoring interaction of biomolecules.
Abstract A phase modulated scheme was presented in a weak measurement based polarimeter, which was realized with spectrum demodulation for the polarization detection. According to the calculation, the phase difference between two orthogonal polarizations reveals a unique feature to enhance the weak value of the system, further optimizing the sensitivity of polarization detection. With the weak measurement in the frequency domain, the polarization angle was monitored in real time by fitting the central wavelength of the output spectrum. Applying an SBC for the phase adjustment, we demonstrated the significance of phase modification in this polarimeter theoretically and experimentally. It follows that an initial phase addition of −1.4958 rad improved the sensitivity, which was about 8.5 times higher than previous weak measurement based polarimeter. As a consequence, besides the advantages of weak measurement for optical rotation detection with spectrum demodulation, a phase modulated polarimeter with a high sensitivity exhibited great potential in investigations involving polarization detection.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
Optical interferometry plays an essential role in precision metrology such as in gravitational wave detection, gyroscopes, and environmental sensing. Weak value amplification enables reaching the shot-noise-limit of sensitivity, which is difficult for most optical sensors, by amplifying the interferometric signal without amplifying certain technical noises. We implement a generalized form of weak value amplification on an integrated photonic platform with a multi-mode interferometer. Our results pave the way for a more sensitive, robust, and compact platform for measuring phase, which can be adapted to fields such as coherent communications and the quantum domain. In this work, we show a 7 dB signal enhancement in our weak value device over a standard Mach-Zehnder interferometer with equal detected optical power, as well as frequency measurements with 2 kHz sensitivity by adding a ring resonator.
Experiments based on a free-space platform have demonstrated that the weak-value amplification (WVA) technique can provide high sensitivity and precision for optical sensing and metrology. To promote this technique for real-world applications, it is more suitable to implement WVA based on an optical-fiber platform due to the lower cost, smaller scale, and higher stability. In contrast to the free-space platform, the birefringence in optical fiber is strong enough to cause polarization cross talk, and the amplitude-type noise must be taken into account. By theoretical analysis and experimental demonstration, we show that the optic-fiber-based WVA is robust in the presence of amplitude-type noise. In our experiment, even the angular misalignment on optical axes at the interface reaches 0.08 rad, and the sensitivity loss can be maintained at less than 3 dB. Moreover, the main results are valid to a simplified detection scheme that was recently proposed that is more compatible with the future design of optical-fiber-based WVA. Our results indicate the feasibility of implementing WVA based on optical fiber, which provides a possible way for designing optical sensors with higher sensitivity and stability in the future.
We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.
We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.