Nonlinear Optics

Sub-Hertz Resonance by Weak Measurement

Jianming Wen, Weizhi Qu, Jian Sun, Shenchao Jin, Yanhua Zhai, Yanhong Xiao, Liang Jiang

Published Jan 1, 2019• 0 citations
Publisher
DOI
10.1364/nlo.2019.nth2a.1

Related papers

Cat state, sub-Planck structure and weak measurement

A. K. Pan, Prasanta Kumar Panigrahi

arXiv:1305.4009•The European Physical Journal D•Aug 1, 2013•6 citations

Sub-Hertz resonance by weak measurement

Weizhi Qu, Shenchao Jin, Jian Sun +3 more

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus has potential in precision measurement applications. Although frequency measurements offer the hitherto highest precision due to the stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we demonstrate a WM-enhanced correlation spectroscopy technique capable of narrowing the resonance linewidth down to 0.1 Hz in a room-temperature atomic vapour cell. The potential of this technique for precision measurement is demonstrated through weak magnetic-field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly orthogonal manner, a sensitivity of 7 fT Hz−1/2 at a low frequency near DC is achieved using only one laser beam with 15 µW of power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian and shed new light on metrology and bio-magnetic field sensing.

arXiv:1812.02551•Nature Communications•Apr 9, 2020•39 citations

Weak measurements with a qubit meter

Shengjun Wu, Klaus Mølmer

arXiv:0909.0841•Physics Letters A•Oct 13, 2009•62 citations

Observation of a sub-Hertz-level Bloch-Siegert shift in a Floquet-engineered optical lattice clock

Anonymous, Xiaotong Lu, Hong Chang +2 more

When a two-level quantum system is driven periodically with a Rabi frequency $\mathrm{\ensuremath{\Omega}}$ comparable to the driving frequency ${\ensuremath{\nu}}_{s}$, the resonant transition frequency deviates from the bare energy gap---an effect known as the Bloch-Siegert shift. Observing sub-Hertz Bloch-Siegert shift is challenging due to its small energy scale and its mixing with other systematic shifts. Using a Floquet-engineered optical lattice clock, we directly observe this sub-hertz shift in ultracold atoms. We tune driving parameters to suppress micromotion and apply a self-comparison stroboscopic method to remove unwanted frequency shifts. Assisted by closed-loop feedback, we achieve high-precision results after one hour of averaging and longer integration will further improve the measurement accuracy.

Physical Review A•Sep 1, 2026•0 citations

Framework of weak measurement with noise

Yutaka Shikano, Akio Hosoya

Physica E Low-dimensional Systems and Nanostructures•Aug 4, 2010•9 citations

High‐Precision Laser Spectrum Analyzer via Digital Decoherence (Laser Photonics Rev. 20(1)/2026)

Zhongwang Pang, Chunyi Li, Hongfei Dai +5 more

Digital Decoherence for Sub-Hertz Laser Analyzer In Research Article e01773, Bo Wang and co-workers propose the concept of digital decoherence. This allows the decoherence process to be realized through a digital delay. Based on this method, a laser spectrum analyzer is achieved for accurate frequency-noise power spectral density measurements of sub-Hertz linewidth lasers. This advance benefits quantum metrology, especially optical clocks.

Laser & Photonics Review•Jan 1, 2026•1 citation
Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus has potential in precision measurement applications. Although frequency measurements offer the hitherto highest precision due to the stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we demonstrate a WM-enhanced correlation spectroscopy technique capable of narrowing the resonance linewidth down to 0.1 Hz in a room-temperature atomic vapour cell. The potential of this technique for precision measurement is demonstrated through weak magnetic-field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly orthogonal manner, a sensitivity of 7 fT Hz−1/2 at a low frequency near DC is achieved using only one laser beam with 15 µW of power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian and shed new light on metrology and bio-magnetic field sensing.
When a two-level quantum system is driven periodically with a Rabi frequency $\mathrm{\ensuremath{\Omega}}$ comparable to the driving frequency ${\ensuremath{\nu}}_{s}$, the resonant transition frequency deviates from the bare energy gap---an effect known as the Bloch-Siegert shift. Observing sub-Hertz Bloch-Siegert shift is challenging due to its small energy scale and its mixing with other systematic shifts. Using a Floquet-engineered optical lattice clock, we directly observe this sub-hertz shift in ultracold atoms. We tune driving parameters to suppress micromotion and apply a self-comparison stroboscopic method to remove unwanted frequency shifts. Assisted by closed-loop feedback, we achieve high-precision results after one hour of averaging and longer integration will further improve the measurement accuracy.