ACTA PHOTONICA SINICA

Accuracy Analysis for Coincidence Measurement of Entangled Photons Calibration

胡友勃 HU You-bo, 李健军 Li Jianjun, 高冬阳 GAO Dong-yang, 汤琪 TANG Qi, 郑小兵 Zheng Xiaobing

Published Jan 1, 2019• 3 citations
Publisher
DOI
10.3788/gzxb20194804.0428002

Related papers

Measurements with Position-Momentum Entangled Photons

Zeenat Baig, Zoya Shafique, Sean J. Bentley

Bulletin of the American Physical Society•Mar 5, 2019•0 citations

Entangled-photon ellipsometry

Alexander V. Sergienko, Ayman F. Abouraddy, Kimani C. Toussaint +2 more

We present a novel quantum interferometric technique to perform ellipsometric measurements. Classical ellipsometric measurements are limited in their accuracy by virtue of the need for an absolutely calibrated source and detector. Mitigating this limitation requires the use of a well-characterized reference sample. Our technique relies on the use of a non-classical optical source, namely polarization-entangled twin photons generated by spontaneous parametric down-conversion from a nonlinear crystal, in conjunction with a coincidence-detection scheme. We have demonstrated that entangled-photon ellipsometry eliminates the necessity of constructing an interferometer altogether and is thereby self-referencing. The underlying physics that leads to this remarkable result is the presence of fourth-order (coincidence) quantum interference of the photon pairs in conjuction with polarization entanglement.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 18, 2003•0 citations

Entanglement-assisted calibration of a photon-number-resolving detector

Brida, Ciavarella, Dagrada +7 more

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations

Polarization-entangled twin-photon ellipsometry

Kimani C. Toussaint, Ayman F. Abouraddy, Matthew T. Corbo +3 more

The high accuracy required in traditional ellipsometric measurements necessitates the absolute calibration of both the source and the detector. We demonstrate that these requirements can be circumvented by using a non-classical source of light, namely, a twin-photon polarization-entangled source that produces type-II spontaneous parametric down-conversion, in conjunction with a novel polarization interferometer and coincidence-counting detection scheme. Our scheme exhibits two features that obviate the requirements of a calibrated source and detector. The first is the twin-photon nature of the source; we are guaranteed, on the detection of a photon in one of the arms of the setup, that its twin will be in the other, effectively serving as calibration of the source. The second is that the polarization entanglement of the source serves as an interferometer, thereby alleviating the need for calibrating the detector. The net result is that absolute ellipsometric data from a sample may be obtained. We present preliminary experimental results showing how the technique operates.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 2, 2002•1 citation

Theory and applications of entangled photons

Amaal M. Ali, Natasha Bastien, Wendy-Ann Gibbons +2 more

•Mar 12, 2012•0 citations

Quantum efficiency calibration of opto-electronic detector by means of correlated photons method

李健军 Jian-jun LI, 郑小兵 Xiaobing Zheng, Yunjun Lu +2 more

A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal.An absolute calibration system of detector quantum efficiency is performed.And its principle and experimental setup are introduced.A continuouswave (CW) ultraviolet (351 nm), diode-pumped, frequency-doubled, and solid-state laser is used to pump BBO crystal.The quantum efficiencies of the photomultiplier at 633, 702, and 789 nm are measured respectively.The coincidence peaks are observed using coincidence circuit.Some measurement factors including the filter bandwidth of trigger channel, the detector position alignment and polarization of the pump light are analyzed.The uncertainties of this calibration method are also analyzed, and the relative uncertainties of total calibration are less than 5.8%.The accuracy of this method could be improved in the future.

Chinese Optics Letters•Jan 1, 2008•5 citations
We present a novel quantum interferometric technique to perform ellipsometric measurements. Classical ellipsometric measurements are limited in their accuracy by virtue of the need for an absolutely calibrated source and detector. Mitigating this limitation requires the use of a well-characterized reference sample. Our technique relies on the use of a non-classical optical source, namely polarization-entangled twin photons generated by spontaneous parametric down-conversion from a nonlinear crystal, in conjunction with a coincidence-detection scheme. We have demonstrated that entangled-photon ellipsometry eliminates the necessity of constructing an interferometer altogether and is thereby self-referencing. The underlying physics that leads to this remarkable result is the presence of fourth-order (coincidence) quantum interference of the photon pairs in conjuction with polarization entanglement.
The high accuracy required in traditional ellipsometric measurements necessitates the absolute calibration of both the source and the detector. We demonstrate that these requirements can be circumvented by using a non-classical source of light, namely, a twin-photon polarization-entangled source that produces type-II spontaneous parametric down-conversion, in conjunction with a novel polarization interferometer and coincidence-counting detection scheme. Our scheme exhibits two features that obviate the requirements of a calibrated source and detector. The first is the twin-photon nature of the source; we are guaranteed, on the detection of a photon in one of the arms of the setup, that its twin will be in the other, effectively serving as calibration of the source. The second is that the polarization entanglement of the source serves as an interferometer, thereby alleviating the need for calibrating the detector. The net result is that absolute ellipsometric data from a sample may be obtained. We present preliminary experimental results showing how the technique operates.
A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal.An absolute calibration system of detector quantum efficiency is performed.And its principle and experimental setup are introduced.A continuouswave (CW) ultraviolet (351 nm), diode-pumped, frequency-doubled, and solid-state laser is used to pump BBO crystal.The quantum efficiencies of the photomultiplier at 633, 702, and 789 nm are measured respectively.The coincidence peaks are observed using coincidence circuit.Some measurement factors including the filter bandwidth of trigger channel, the detector position alignment and polarization of the pump light are analyzed.The uncertainties of this calibration method are also analyzed, and the relative uncertainties of total calibration are less than 5.8%.The accuracy of this method could be improved in the future.