Chinese Journal of Physics

Determination of the geometric parameters and of a linear Paul trap

H.X. Li, Yi Zhang, Shuxian He, X. Tong

Published May 1, 2019• 12 citations
Publisher

Abstract

An effective method for determining the geometric parameters of a linear Paul trap is provided and carried out in this paper. The method is based on exciting the secular motion of laser-cooled Ca+ ions in a linear Paul trap with varied trapping potentials. Taking advantage of the segmented structure of the linear Paul trap, both the axial and the radial geometric parameters are obtained by applying external excitation fields to the trapping electrodes directly. The axial geometric parameter of our linear Paul trap is determined to be 0.374(3), and, for the first time, the radial geometric parameter is determined to be 0.928(2).

DOI
10.1016/j.cjph.2019.03.017

Related papers

Influence of End Cap Structure on the Axial Geometric Parameter of the Linear Paul Trap

Lin Li, Zi Li

Through finite-element simulation, the axial potential distribution of the ion trap is analyzed. The effects of the central hole diameter of the end cap and the spacing between the two end caps on the axial geometric parameters of the ion trap are investigated. Based on these findings, a set of linear Paul traps is designed by selecting suitable end caps and quadrupoles. Stable trapping of calcium ions (Ca+) is successfully achieved, and these ions are subsequently laser-cooled into ionic Coulomb crystals. In the experiment, secular motion excitation of the Ca+ ion Coulomb crystal is performed, yielding an axial geometric parameter of 0.115(1) for the ion trap. This value aligns well with the simulation result of 0.114(2). The precise determination of the axial geometric parameter provides a solid foundation for subsequent high-precision optical or mass spectrometry measurements.

Atoms•Feb 5, 2026•0 citations

Design and Characteristic Measurement of Miniature Three-Segment Linear Paul Trap

T. Furukawa, Jin Nishimura, U. Tanaka +1 more

We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.

Japanese Journal of Applied Physics•Oct 1, 2005•10 citations

Crystalline ion structures in a Paul trap

M. Block, A. Drakoudis, H Leuthner +6 more

We have observed crystalline structures formed by laser cooled Ca + ions in a three-dimensional confining potential. The potential has been realized using a linear Paul trap with different ratios of potential strength in the axial and radial directions. For radial confining potentials stronger than the axial potential, we find linear structures with a continuous transition from strings to helices with decreasing potential asymmetry. When a quasi-two-dimensional potential is formed we observe ring structures with a given maximum ion number per ring which we followed up to 19. The observations are essentially in agreement with molecular dynamics calculations in static two-dimensional potentials.

Journal of Physics B Atomic Molecular and Optical Physics•May 16, 2000•52 citations

Measurement of Secular Motion Frequency in Miniature Paul Trap to Ascertain the Stability Parameters

Bin Guo, Guan Hua, Liu Qu +3 more

40 Ca + ions are trapped and laser cooled in a miniature Paul trap. The secular motion was observed by the radio-frequency resonance of the ion cloud and Zeeman profile sidebands of a single ion experimentally. The trap stability parameters a and q are determined with an uncertainty under 1 % by the secular motion frequency measurement. The trap efficiency is 0.75. A practicable suggestion is given for the benefits of a new trap design.

Chinese Physics Letters•Jan 1, 2010•4 citations

Optimization of segmented linear Paul traps and transport of stored particles

S. Schulz, Ulrich Poschinger, Kilian Singer +1 more

Abstract Single ions held in linear Paul traps are promising candidates for a future quantum computer. Here, we discuss a two‐layer microstructured segmented linear ion trap. The radial and axial potentials are obtained from numeric field simulations and the geometry of the trap is optimized. As the trap electrodes are segmented in the axial direction, the trap allows the transport of ions between different spatial regions. Starting with realistic numerically obtained axial potentials, we optimize the transport of an ion such that the motional degrees of freedom are not excited, even though the transport speed far exceeds the adiabatic regime. In our optimization we achieve a transport within roughly two oscillation periods in the axial trap potential compared to typical adiabatic transports that take of the order 102 oscillations. Furthermore heating due to quantum mechanical effects is estimated and suppression strategies are proposed.

arXiv:quant-ph/0607217•Fortschritte der Physik•Aug 1, 2006•75 citations

Nonlinear Resonances of Laser Cooled Ions in a Linear Paul Trap due to the Anharmonicity of the Trap Potential

Toshihiko MORI, Kenji Toyoda, Masayoshi Watanabe +1 more

The anharmonicity of the trap potential influences the motion of trapped and laser-cooled ions. The magnitudes of higher-order components of the trap potential depend on the electrode geometry. In this paper we provide a numerical study of the anharmonicity of linear Paul trap potentials with different electorode geometies. We have also experimentally observed nonlinear resonances of laser-cooled ions, and have studied the effect of anharmonicity in three types of liner Paul trap that have different distances between electrodes.

The Review of Laser Engineering•Jan 1, 2003•1 citation
An effective method for determining the geometric parameters of a linear Paul trap is provided and carried out in this paper. The method is based on exciting the secular motion of laser-cooled Ca+ ions in a linear Paul trap with varied trapping potentials. Taking advantage of the segmented structure of the linear Paul trap, both the axial and the radial geometric parameters are obtained by applying external excitation fields to the trapping electrodes directly. The axial geometric parameter of our linear Paul trap is determined to be 0.374(3), and, for the first time, the radial geometric parameter is determined to be 0.928(2).
Through finite-element simulation, the axial potential distribution of the ion trap is analyzed. The effects of the central hole diameter of the end cap and the spacing between the two end caps on the axial geometric parameters of the ion trap are investigated. Based on these findings, a set of linear Paul traps is designed by selecting suitable end caps and quadrupoles. Stable trapping of calcium ions (Ca+) is successfully achieved, and these ions are subsequently laser-cooled into ionic Coulomb crystals. In the experiment, secular motion excitation of the Ca+ ion Coulomb crystal is performed, yielding an axial geometric parameter of 0.115(1) for the ion trap. This value aligns well with the simulation result of 0.114(2). The precise determination of the axial geometric parameter provides a solid foundation for subsequent high-precision optical or mass spectrometry measurements.
We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.
We have observed crystalline structures formed by laser cooled Ca + ions in a three-dimensional confining potential. The potential has been realized using a linear Paul trap with different ratios of potential strength in the axial and radial directions. For radial confining potentials stronger than the axial potential, we find linear structures with a continuous transition from strings to helices with decreasing potential asymmetry. When a quasi-two-dimensional potential is formed we observe ring structures with a given maximum ion number per ring which we followed up to 19. The observations are essentially in agreement with molecular dynamics calculations in static two-dimensional potentials.
Abstract Single ions held in linear Paul traps are promising candidates for a future quantum computer. Here, we discuss a two‐layer microstructured segmented linear ion trap. The radial and axial potentials are obtained from numeric field simulations and the geometry of the trap is optimized. As the trap electrodes are segmented in the axial direction, the trap allows the transport of ions between different spatial regions. Starting with realistic numerically obtained axial potentials, we optimize the transport of an ion such that the motional degrees of freedom are not excited, even though the transport speed far exceeds the adiabatic regime. In our optimization we achieve a transport within roughly two oscillation periods in the axial trap potential compared to typical adiabatic transports that take of the order 102 oscillations. Furthermore heating due to quantum mechanical effects is estimated and suppression strategies are proposed.
The anharmonicity of the trap potential influences the motion of trapped and laser-cooled ions. The magnitudes of higher-order components of the trap potential depend on the electrode geometry. In this paper we provide a numerical study of the anharmonicity of linear Paul trap potentials with different electorode geometies. We have also experimentally observed nonlinear resonances of laser-cooled ions, and have studied the effect of anharmonicity in three types of liner Paul trap that have different distances between electrodes.