Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics

Fabrication and characterization of short acetylene-filled photonic microcells

Sajed Hosseini-Zavareh, Ryan Luder, Manasadevi P. Thirugnanasambandam, H. W. Kushan Weerasinghe, Brian R. Washburn, Kristan L. Corwin

Published Apr 1, 2019• 6 citations
Publisher

Abstract

) accuracy. Using an earlier Q-tipping technique, 37% off-resonant transmission and 5 MHz accuracy were achieved in finding the line center, but a large 13% etalon-like effect appears on the wings of the optical depth. The etalon-like effect is reduced to less than 1% by using the tapering method. In both cases, the microcells could be connectorized, albeit with a reduction in off-resonant transmission efficiency, for integration into multimode fibers or free-space optical systems. Although contamination is introduced during both fabrication techniques, the P13 PMC line center shifts are small with respect to the sub-Doppler line center. This shows that the PMC can be used for moderate-accuracy frequency measurements. Finally, repeatable measurements show that PMCs are stable in terms of total pressure over approximately one year.

DOI
10.1364/ao.58.002809

Related papers

Conception et élaboration de micro-capsules photoniques pour les références de fréquences et la photonique atomique

Thomas Billotte

Ces travaux portent sur la fabrication et l’optimisation de microcellules photoniques (PMC) à la fois dans le cadre des vapeurs moléculaire comme l’acétylène mais aussi alcaline comme le rubidium. La chaîne de fabrication complète de fabrication y est présentée en partant du design de la fibre creuse où nous avons choisi d’utiliser une fibre hybride tubulaire/Kagomé pour son large coeur, ses faibles pertes et son contenu monomode. Après avoir fabriqué cette fibre, nous présentons un procédé de remplissage et de fermeture avec le gaz souhaité ne souffrant d’aucune source de contamination. Cela nous a permis la fabrication d’une PMC à base d’acétylène présentant de faibles pertes à l’injection et un nouvel état de l’art en terme de pic par spectroscopie d’absorption saturée avec 19MHz de largeur et 30% de contraste. Nous poussons ensuite l’étude de la spectroscopie sub-Doppler en fonction du mode utilisé grâce à la fabrication d’une fibre guidant préférentiellement un mode d’ordre supérieur qui a pour conséquence l’obtention d’un contraste plus élevé et un décalage en fréquence du pic de transparence. Le deuxième axe de cette thèse tente d’appliquer aux vapeurs alcalines les procédés précédents et d’autre pour aller vers la première PMC totalement fibrée à vapeur de rubidium. Parmi ces pistes, on note l’utilisation de revêtements intra-fibre qui permettent de limiter l’adsorption du rubidium et sa réactivité ou encore améliorant ses propriété anti-relaxantes. La caractérisation de ces dépôts sur les parois du coeur de fibres creuses a été réalisée intra-fibre par une mesure de la relaxation de polarisation.

•Sep 28, 2021•0 citations

Large-core photonic microcells for coherent optics and laser metrology

Natalie V. Wheeler, Michael D. W. Grogan, Yingying Wang +3 more

A photonic microcell (PMC) is a length of gas-filled hollow core-photonic crystal fiber (HC-PCF) which is hermetically sealed at both ends by splicing to standard single mode fiber. We describe advances in the fabrication technique of PMCs which enable large core Kagome-lattice HC-PCFs to be integrated into PMC form. The modified fabrication technique uses fiber-tapering to accommodate the large dimensions of the fiber and enables low loss splices with single mode fiber by reducing mode field mismatch. Splice losses as low as 0.6 dB are achieved between 1-cell defect Kagome HC-PCF and single mode fiber. Relative to the previously reported PMCs, which were based on photonic bandgap HC-PCF, the present Kagome HC-PCF based PMC provides broad optical transmission, surface mode-free guidance and larger core at the cost of slightly increased fiber attenuation (~0.2 dB/m). Therefore, the integration of this fiber into PMC form opens up new applications for PMC-based devices. The advantage of the large core dimensions and surface mode free guidance for quantum optics in gas-filled HC-PCF are demonstrated by generation of narrow sub-Doppler features in an acetylenefilled large core PMC.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 10, 2011•6 citations

Slow and superluminal light pulses via EIT in a 20-metre acetylene-filled photonic microcell

Wheeler, Couny, Benabid

Quantum Electronics and Laser Science Conference•Jan 1, 2009•0 citations

Molecular and atomic confinement in large core photonic microcells for slow light and laser metrology applications

Natalie V. Wheeler

This thesis describes developments in the fabrication and applications of photonic microcells (PMCs). A PMC is a length of gas-filled hollow core-photonic crystal fibre (HC-PCF) that is hermetically sealed by splicing both ends to standard single mode fibre. A PMC enables integration of gas-filled HC-PCF into all-fibre systems with low insertion loss. PMCs have applications in coherent optics and metrology, where specific HC-PCF designs are advantageous. Two types of state-of-the-art HC-PCF, double bandgap HCPCF and large-pitch Kagome fibre, are fabricated. The double bandgap HC-PCF extends the usable bandwidth of the fibre by providing low loss guidance across two transmission bands. The large-pitch Kagome HC-PCF has a record low attenuation of 0.3 dB/m at 800 nm, while maintaining broadband guidance, which is partially attributed to the core shape. Three distinct developments in the field of PMCs are described. Firstly, a record length 20 metre acetylene-filled PMC is fabricated which is the key component in the first demonstration of an all-fibre slow and fast light system based on electromagnetically induced transparency. Secondly, a technique based on fibre tapering is presented which enables low loss integration of large core Kagome HC-PCFs into PMC form. Thirdly, micromirrors are developed and integrated with HC-PCF to confine light in the longitudinal dimension, providing a means to fabricate multi-pass PMCs. Two uncoated micromirrors are used to form a low finesse microcavity in Kagome HC-PCF, with record high fringe visibility using reflections from a silica/air junction. In collaboration with Kansas State University, an acetylene optical reference with sub-10 KHz accuracy and the first acetylene laser based on population inversion are demonstrated using Kagome HC-PCF.Finally, this thesis reports on rubidium vapour loading in HC-PCF with the ultimate aim being the production of a rubidium-filled PMC for applications in metrology. Preliminary results highlight the limited loading distance of the current technique and modified loading schemes are outlined accordingly.

•Nov 1, 2010•0 citations

Slow and Superluminal Light Pulses via EIT in a 20-metre Acetylene-filled Photonic Microcell

Natalie V. Wheeler, P. S. Light, F. Couny +1 more

Electromagnetically induced transparencies are recorded in a 20 metre acetylene-filled photonic microcell and used to observe pulses of probe light delayed (advanced) by up to 5 ns (1 ns). Suggested applications include interferometry.

Conference on Lasers and Electro-Optics•Jan 1, 2009•0 citations

Assembly process and sub-Doppler spectroscopy of end-capped photonic micro-cell

Thomas Billotte, Matthieu Chafer, Martin Maurel +4 more

Generation of sub-Doppler spectral lines in compact devices is very useful in bringing functionalities such as laser-frequency stabilization, slow light application or quantum sensing to a wider and friendlier use. An all-fiber Photonic MicroCell (PMC), which consists of a gas-filled hollow core photonic crystal fiber (HCPCF) hermetically spliced to a solid optical fiber [1], is one of the most promising of such devices because of its ultra-long interaction length. Thus far, the PMC assembly processes are either limited to a short range of HCPCF core diameter [2], or entails the use of glue [3], or exhibit high injection losses (~10dB) [4]. Here, we report on a 7-meter contaminant free and single-mode C2H2-PMC. The process consists of end-capping a 80µbar acetylene-filled HCPCF via heat-collapsing a fused borosilicate sleeve on the two HCPCF tips. The process requires no helium gas [2] nor glue [3], which are potential pollution sources, and keeps the physical integrity of the HCPCF intact. The used HCPCF exhibits a novel cladding lattice and operates in a robust single-mode fashion [5]. The fiber has a 30 µm core diameter, a 10dB/km transmission loss at 1540 nm. The resulted PMC has polished and mounted ends to FC/APC connectors for integration (Fig. 1(a)), exhibits a total insertion loss of ~2dB and a motion-resistant single-mode guidance (see reconstructed near field in Fig. 1 (b)). The PMC was then used to generate saturable absorption spectroscopy (SAS) measurement (Fig. 1 (b-c))). The observed saturable absorption peak reaches 25% contrast and 20MHz linewidth (FWHM) for ~190mW of pump power that is the highest observed contrast in a fully sealed PMC [6]. The evolution of the SA peak characteristics over pump power are represented in Fig. 1 (e), and shows for pump power of less than 100 mW a transit-time limited linewidth (19MHz), thus indicating no additional collisional dephasing that could be induced by contaminant during the assembly process. The linewidth was monitored over 3 months for 23 mW pump power with no significant variation (Fig.1(f)), demonstrating thus its hermeticity, and its suitability for long time and mobile applications. Fig. 1. (a) FC/APC patch-cord like final PMC. (b) Near field intensity profile at the output of polished PMC. (c) Normalized SAS measurement on P9 absorption line of acetylene (1530.371nm) in purple line, simulation of SAS signal for 31 µbar pressure in dashed line. (d) SA contrast zoomed in SA peak with numerical calculation in dashed line. (e) Experimental (dots) and calculated (line) SA transparency peak contrast and linewidth evolution with pump power. The dashed line correspond to the transit time limit. (f) Evolution of SA FWHM during 95 days for a pump power of 23mW.

•Aug 30, 2020•0 citations
) accuracy. Using an earlier Q-tipping technique, 37% off-resonant transmission and 5 MHz accuracy were achieved in finding the line center, but a large 13% etalon-like effect appears on the wings of the optical depth. The etalon-like effect is reduced to less than 1% by using the tapering method. In both cases, the microcells could be connectorized, albeit with a reduction in off-resonant transmission efficiency, for integration into multimode fibers or free-space optical systems. Although contamination is introduced during both fabrication techniques, the P13 PMC line center shifts are small with respect to the sub-Doppler line center. This shows that the PMC can be used for moderate-accuracy frequency measurements. Finally, repeatable measurements show that PMCs are stable in terms of total pressure over approximately one year.
Ces travaux portent sur la fabrication et l’optimisation de microcellules photoniques (PMC) à la fois dans le cadre des vapeurs moléculaire comme l’acétylène mais aussi alcaline comme le rubidium. La chaîne de fabrication complète de fabrication y est présentée en partant du design de la fibre creuse où nous avons choisi d’utiliser une fibre hybride tubulaire/Kagomé pour son large coeur, ses faibles pertes et son contenu monomode. Après avoir fabriqué cette fibre, nous présentons un procédé de remplissage et de fermeture avec le gaz souhaité ne souffrant d’aucune source de contamination. Cela nous a permis la fabrication d’une PMC à base d’acétylène présentant de faibles pertes à l’injection et un nouvel état de l’art en terme de pic par spectroscopie d’absorption saturée avec 19MHz de largeur et 30% de contraste. Nous poussons ensuite l’étude de la spectroscopie sub-Doppler en fonction du mode utilisé grâce à la fabrication d’une fibre guidant préférentiellement un mode d’ordre supérieur qui a pour conséquence l’obtention d’un contraste plus élevé et un décalage en fréquence du pic de transparence. Le deuxième axe de cette thèse tente d’appliquer aux vapeurs alcalines les procédés précédents et d’autre pour aller vers la première PMC totalement fibrée à vapeur de rubidium. Parmi ces pistes, on note l’utilisation de revêtements intra-fibre qui permettent de limiter l’adsorption du rubidium et sa réactivité ou encore améliorant ses propriété anti-relaxantes. La caractérisation de ces dépôts sur les parois du coeur de fibres creuses a été réalisée intra-fibre par une mesure de la relaxation de polarisation.
A photonic microcell (PMC) is a length of gas-filled hollow core-photonic crystal fiber (HC-PCF) which is hermetically sealed at both ends by splicing to standard single mode fiber. We describe advances in the fabrication technique of PMCs which enable large core Kagome-lattice HC-PCFs to be integrated into PMC form. The modified fabrication technique uses fiber-tapering to accommodate the large dimensions of the fiber and enables low loss splices with single mode fiber by reducing mode field mismatch. Splice losses as low as 0.6 dB are achieved between 1-cell defect Kagome HC-PCF and single mode fiber. Relative to the previously reported PMCs, which were based on photonic bandgap HC-PCF, the present Kagome HC-PCF based PMC provides broad optical transmission, surface mode-free guidance and larger core at the cost of slightly increased fiber attenuation (~0.2 dB/m). Therefore, the integration of this fiber into PMC form opens up new applications for PMC-based devices. The advantage of the large core dimensions and surface mode free guidance for quantum optics in gas-filled HC-PCF are demonstrated by generation of narrow sub-Doppler features in an acetylenefilled large core PMC.
This thesis describes developments in the fabrication and applications of photonic microcells (PMCs). A PMC is a length of gas-filled hollow core-photonic crystal fibre (HC-PCF) that is hermetically sealed by splicing both ends to standard single mode fibre. A PMC enables integration of gas-filled HC-PCF into all-fibre systems with low insertion loss. PMCs have applications in coherent optics and metrology, where specific HC-PCF designs are advantageous. Two types of state-of-the-art HC-PCF, double bandgap HCPCF and large-pitch Kagome fibre, are fabricated. The double bandgap HC-PCF extends the usable bandwidth of the fibre by providing low loss guidance across two transmission bands. The large-pitch Kagome HC-PCF has a record low attenuation of 0.3 dB/m at 800 nm, while maintaining broadband guidance, which is partially attributed to the core shape. Three distinct developments in the field of PMCs are described. Firstly, a record length 20 metre acetylene-filled PMC is fabricated which is the key component in the first demonstration of an all-fibre slow and fast light system based on electromagnetically induced transparency. Secondly, a technique based on fibre tapering is presented which enables low loss integration of large core Kagome HC-PCFs into PMC form. Thirdly, micromirrors are developed and integrated with HC-PCF to confine light in the longitudinal dimension, providing a means to fabricate multi-pass PMCs. Two uncoated micromirrors are used to form a low finesse microcavity in Kagome HC-PCF, with record high fringe visibility using reflections from a silica/air junction. In collaboration with Kansas State University, an acetylene optical reference with sub-10 KHz accuracy and the first acetylene laser based on population inversion are demonstrated using Kagome HC-PCF.Finally, this thesis reports on rubidium vapour loading in HC-PCF with the ultimate aim being the production of a rubidium-filled PMC for applications in metrology. Preliminary results highlight the limited loading distance of the current technique and modified loading schemes are outlined accordingly.
Generation of sub-Doppler spectral lines in compact devices is very useful in bringing functionalities such as laser-frequency stabilization, slow light application or quantum sensing to a wider and friendlier use. An all-fiber Photonic MicroCell (PMC), which consists of a gas-filled hollow core photonic crystal fiber (HCPCF) hermetically spliced to a solid optical fiber [1], is one of the most promising of such devices because of its ultra-long interaction length. Thus far, the PMC assembly processes are either limited to a short range of HCPCF core diameter [2], or entails the use of glue [3], or exhibit high injection losses (~10dB) [4]. Here, we report on a 7-meter contaminant free and single-mode C2H2-PMC. The process consists of end-capping a 80µbar acetylene-filled HCPCF via heat-collapsing a fused borosilicate sleeve on the two HCPCF tips. The process requires no helium gas [2] nor glue [3], which are potential pollution sources, and keeps the physical integrity of the HCPCF intact. The used HCPCF exhibits a novel cladding lattice and operates in a robust single-mode fashion [5]. The fiber has a 30 µm core diameter, a 10dB/km transmission loss at 1540 nm. The resulted PMC has polished and mounted ends to FC/APC connectors for integration (Fig. 1(a)), exhibits a total insertion loss of ~2dB and a motion-resistant single-mode guidance (see reconstructed near field in Fig. 1 (b)). The PMC was then used to generate saturable absorption spectroscopy (SAS) measurement (Fig. 1 (b-c))). The observed saturable absorption peak reaches 25% contrast and 20MHz linewidth (FWHM) for ~190mW of pump power that is the highest observed contrast in a fully sealed PMC [6]. The evolution of the SA peak characteristics over pump power are represented in Fig. 1 (e), and shows for pump power of less than 100 mW a transit-time limited linewidth (19MHz), thus indicating no additional collisional dephasing that could be induced by contaminant during the assembly process. The linewidth was monitored over 3 months for 23 mW pump power with no significant variation (Fig.1(f)), demonstrating thus its hermeticity, and its suitability for long time and mobile applications. Fig. 1. (a) FC/APC patch-cord like final PMC. (b) Near field intensity profile at the output of polished PMC. (c) Normalized SAS measurement on P9 absorption line of acetylene (1530.371nm) in purple line, simulation of SAS signal for 31 µbar pressure in dashed line. (d) SA contrast zoomed in SA peak with numerical calculation in dashed line. (e) Experimental (dots) and calculated (line) SA transparency peak contrast and linewidth evolution with pump power. The dashed line correspond to the transit time limit. (f) Evolution of SA FWHM during 95 days for a pump power of 23mW.