Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Validation of échelle-based quantum-classical discriminator with novelty SPAD array sensor

Valentin Mitev, Laurent P. Balet, Leonardo Gasparini, Matteo Perenzoni, Bänz Bessire, André Stefanov, Alexander B. Mikhalychev, Dmitri S. Mogilevtsev, D. L. Boïko, Nicolas Torcheboeuf

Published Mar 1, 2019• 2 citations
Publisher

Abstract

Imaging with non-classical photons allows to bypass the Rayleigh resolution limit and classical shot-noise level. One step towards imaging demonstration with large photon numbers is the separation of non-classical photon states from the classical photons, thus increasing dynamic range and signal to background contrast on the detector. We demonstrate the feasibility of such separation by an échelle grating at high diffraction orders. In our demonstration, a PPKTP crystal generates entangled photon pairs in type-0 SPDC. The crystal is cw pumped and produces non-collinear degenerated photon pairs at 810nm. The classical light states are produced by a VCSEL at nearly same wavelength. After diffraction on echelle grating, the spatial far-field patterns and the photon arrival times are recorded by a novel 32×32 SPAD array sensor with 160 ps timing resolution. It allows real-time monitoring of the first- and second order correlation patterns. Within the observation window, we detected correlated biphoton arrivals in the four diffraction orders corresponding to their de Broglie wavelength, which is a half of the classical wavelength. Respectively a half of these diffraction orders is prohibited for classical photons. Placing a slit mask in these orders allows us to transmit only non-classical photon state and block the classical ones. We report on a series of experiments elucidating spatial and temporal correlations at the output of such quantum –classical photon discriminator. Those results could be used for the separation of biphotons from classical photons at the same wavelength in high-intensity light sources.

DOI
10.1117/12.2508555

Related papers

Validation of ÉChelle-Based Quantum-Classical Discriminator with Novelty Spad Array Sensor

Valentin Mitev, D. L. Boïko, Laurent P. Balet +7 more

Imaging with non-classical photons allows one to bypass the Rayleigh resolution limit and classical shot-noise level [1, 2]. Such schemes will operate with large photon number, produced by sources, where the entangled and classical states have the same wavelength. In this case, the discrimination of the classical and quantum states by wavelength selection with optical filters is not possible. It has been already demonstrated, that the diffraction of bi-photons at reflection or transmission gratings manifests a pattern equivalent to that of classical photons with half of their wavelength [3, 4]. These demonstrations point to the use of quantum diffraction in discriminating quantum and classical states, having the same (or close) wavelength. The motivation in this work is to validate the approach of quantum-classical photons discrimination.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•1 citation

Analysis of a quantum imaging system based on SPAD detection

Fabio Severini, Francesca Madonini, Federica Villa

The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations

Quantum Ghost Imaging of Remote Targets With Novel SPAD Technology

Alessia Suprano, Massimiliano Proietti, Francesco Poggiali +9 more

Low-light-level imaging in the infrared regime could find applications in areas ranging from technological to biological. Still, its development is limited by the inefficiency of silicon-based detectors in this regime. Quantum Ghost Imaging (QGI) can address this limitation by allowing the separation of illumination and imaging [1]. This is accomplished by generating non-degenerate correlated photon pairs, whose infrared photon probes the object and is detected by an InGaAs bucket detector, while the spatial distribution of the visible one is collected by a single-photon sensitive silicon camera. Traditional QGI setups evaluate photon correlations through “heralding”, by triggering the camera upon idler detection and thus require an image-preserving delay-line, which limits their use for remote sensing [1]. In asynchronous QGI (aQGI) cameras are replaced with SPAD arrays [2] able to record photon timestamp with picoseconds precision. By identifying pairs through timestamps comparison, the mentioned limitations are resolved [3], enabling applications with reflective or diffusive objects where the timestamp delay depends on the object's position. In this work, we propose and demonstrate an experimental QGI setup for remote sensing in reflection configuration (Fig. 1). Collinear non-degenerate pairs of single-photons at 550 nm and 1550 nm are generated by pumping a 2 mm-long type-0 ppKTP crystal with a 405 nm laser. To enable imaging of objects at varying distances, we implemented a momentum-correlation-based setup. Infrared photons interacting with the object were collected by commercially available InGaAs SPAD detectors, while the visible photons were directly captured using a prototype silicon SPAD array developed by Politecnico di Milano [4]. It is based on a 32×32 SPAD, with in-pixel TDCs, and on-chip microlenses are employed to reach a fill factor of 78%. The time resolution is adjustable down to 250 ps, with 1 μs Full Scale Range (FSR). The measurement duty cycle (i.e. the ration of the TDC FSR and the frame time) can be increased with a multi-gate acquisition scheme. To validate the efficiency of our setup, we tested it using a proof-of-principle object, as shown in Fig. 1b. The reconstructed images, captured with the object placed at 30 cm intervals in an acquisition time of only 30 s, are shown in Fig. 1c. In summary, the shown results confirm the potential of the proposed setup for remote sensing applications, particularly for reflective or diffusive objects. Moreover, the proposed approach could offers the possibility of significantly reduce acquisition times compared to standard QGI setups.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

SUPERTWIN: towards 100kpixel CMOS quantum image sensors for quantum optics applications

Leonardo Gasparini, Bänz Bessire, Manuel Unternährer +4 more

Quantum imaging uses entangled photons to overcome the limits of a classical-light apparatus in terms of image quality, beating the standard shot-noise limit, and exceeding the Abbe diffraction limit for resolution. In today experiments, the spatial properties of entangled photons are recorded by means of complex and slow setups that include either the motorized scanning of single-pixel single-photon detectors, such as Photo-Multiplier Tubes (PMT) or Silicon Photo- Multipliers (SiPM), or the use of low frame rate intensified CCD cameras. CMOS arrays of Single Photon Avalanche Diodes (SPAD) represent a relatively recent technology that may lead to simpler setups and faster acquisition. They are spatially- and time-resolved single-photon detectors, i.e. they can provide the position within the array and the time of arrival of every detected photon with <100 ps resolution. SUPERTWIN is a European H2020 project aiming at developing the technological building blocks (emitter, detector and system) for a new, all solid-state quantum microscope system exploiting entangled photons to overcome the Rayleigh limit, targeting a resolution of 40nm. This work provides the measurement results of the 2nd order cross-correlation function relative to a flux of entangled photon pairs acquired with a fully digital 8×16 pixel SPAD array in CMOS technology. The limitations for application in quantum optics of the employed architecture and of other solutions in the literature will be analyzed, with emphasis on crosstalk. Then, the specifications for a dedicated detector will be given, paving the way for future implementations of 100kpixel Quantum Image Sensors.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 27, 2017•21 citations

Quantum diffraction of biphotons at a blazed grating

Martin R. Ostermeyer, Dirk Puhlmann, D. Korn

Correlations between photons are interesting for a number of applications and concepts in metrology in particular for resolution improvements in different methods of quantum imaging. Since Fock-states of N-photons of wavelength lambda in interference schemes acquire N-times the phase shift of single photons these states can appear as if they had a de Broglie wavelength of lambda/N. A biphoton beam diffracted at a blazed grating shows this reduced de Broglie wavelength. This experiment can be seen as a purification of biphotons of a certain correlation strength on the one hand. On the other hand the evaluation of the one-photon and two-photon rate distributions in the Fraunhofer far field of the grating allows for an analysis of the spatial correlation between the photons. An experimental demonstration of these ideas tested for a biphoton beam generated by parametric down conversion (PDC) is reported. We demonstrate in addition that the existence of higher order spatial modes is important to observe strong spatial correlations and to observe the photonic de Broglie wavelength of lambda/2 for biphotons.

arXiv:0903.2756•Journal of the Optical Society of America B•Nov 18, 2009•5 citations

Quantum diffraction and interference of biphotons generated by parametric down conversion

Ryōsuke Shimizu, Keiichi Edamatsu, T. Itoh

Summary form only given. We demonstrate a proof-of-principle experiment of quantum lithography utilizing parametric down-converted photons and a transmission grating, and show that the diffraction of a multiphoton state can be also explained by the concept of the photonic de Broglie wave. Pairs of frequency-degenerate photons were collinearly generated by spontaneous parametric down-conversion (SPDC) in a 5 mm long KNbO/sub 3/ (KN) crystal pumped by the second harmonic light of a single longitudinal mode Ti:sapphire laser operating at 861.5 nm. The photon pairs were diffracted by a transmission grating (slit width: 125 /spl mu/m, period: 250 /spl mu/m), placed just after the KN crystal. In this geometry, each photon pair passes together through one of the grating slits. By rotating a mirror, we recorded spatial diffraction-interference patterns at a two-photon detector consisting of two avalanche photodiodes. For comparison, we also observed diffraction-interference patterns of chaotic light from a tungsten lamp using the same apparatus.

Quantum Electronics and Laser Science Conference•Jun 25, 2003•0 citations
Imaging with non-classical photons allows to bypass the Rayleigh resolution limit and classical shot-noise level. One step towards imaging demonstration with large photon numbers is the separation of non-classical photon states from the classical photons, thus increasing dynamic range and signal to background contrast on the detector. We demonstrate the feasibility of such separation by an échelle grating at high diffraction orders. In our demonstration, a PPKTP crystal generates entangled photon pairs in type-0 SPDC. The crystal is cw pumped and produces non-collinear degenerated photon pairs at 810nm. The classical light states are produced by a VCSEL at nearly same wavelength. After diffraction on echelle grating, the spatial far-field patterns and the photon arrival times are recorded by a novel 32×32 SPAD array sensor with 160 ps timing resolution. It allows real-time monitoring of the first- and second order correlation patterns. Within the observation window, we detected correlated biphoton arrivals in the four diffraction orders corresponding to their de Broglie wavelength, which is a half of the classical wavelength. Respectively a half of these diffraction orders is prohibited for classical photons. Placing a slit mask in these orders allows us to transmit only non-classical photon state and block the classical ones. We report on a series of experiments elucidating spatial and temporal correlations at the output of such quantum –classical photon discriminator. Those results could be used for the separation of biphotons from classical photons at the same wavelength in high-intensity light sources.
Imaging with non-classical photons allows one to bypass the Rayleigh resolution limit and classical shot-noise level [1, 2]. Such schemes will operate with large photon number, produced by sources, where the entangled and classical states have the same wavelength. In this case, the discrimination of the classical and quantum states by wavelength selection with optical filters is not possible. It has been already demonstrated, that the diffraction of bi-photons at reflection or transmission gratings manifests a pattern equivalent to that of classical photons with half of their wavelength [3, 4]. These demonstrations point to the use of quantum diffraction in discriminating quantum and classical states, having the same (or close) wavelength. The motivation in this work is to validate the approach of quantum-classical photons discrimination.
The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}
Low-light-level imaging in the infrared regime could find applications in areas ranging from technological to biological. Still, its development is limited by the inefficiency of silicon-based detectors in this regime. Quantum Ghost Imaging (QGI) can address this limitation by allowing the separation of illumination and imaging [1]. This is accomplished by generating non-degenerate correlated photon pairs, whose infrared photon probes the object and is detected by an InGaAs bucket detector, while the spatial distribution of the visible one is collected by a single-photon sensitive silicon camera. Traditional QGI setups evaluate photon correlations through “heralding”, by triggering the camera upon idler detection and thus require an image-preserving delay-line, which limits their use for remote sensing [1]. In asynchronous QGI (aQGI) cameras are replaced with SPAD arrays [2] able to record photon timestamp with picoseconds precision. By identifying pairs through timestamps comparison, the mentioned limitations are resolved [3], enabling applications with reflective or diffusive objects where the timestamp delay depends on the object's position. In this work, we propose and demonstrate an experimental QGI setup for remote sensing in reflection configuration (Fig. 1). Collinear non-degenerate pairs of single-photons at 550 nm and 1550 nm are generated by pumping a 2 mm-long type-0 ppKTP crystal with a 405 nm laser. To enable imaging of objects at varying distances, we implemented a momentum-correlation-based setup. Infrared photons interacting with the object were collected by commercially available InGaAs SPAD detectors, while the visible photons were directly captured using a prototype silicon SPAD array developed by Politecnico di Milano [4]. It is based on a 32×32 SPAD, with in-pixel TDCs, and on-chip microlenses are employed to reach a fill factor of 78%. The time resolution is adjustable down to 250 ps, with 1 μs Full Scale Range (FSR). The measurement duty cycle (i.e. the ration of the TDC FSR and the frame time) can be increased with a multi-gate acquisition scheme. To validate the efficiency of our setup, we tested it using a proof-of-principle object, as shown in Fig. 1b. The reconstructed images, captured with the object placed at 30 cm intervals in an acquisition time of only 30 s, are shown in Fig. 1c. In summary, the shown results confirm the potential of the proposed setup for remote sensing applications, particularly for reflective or diffusive objects. Moreover, the proposed approach could offers the possibility of significantly reduce acquisition times compared to standard QGI setups.
Quantum imaging uses entangled photons to overcome the limits of a classical-light apparatus in terms of image quality, beating the standard shot-noise limit, and exceeding the Abbe diffraction limit for resolution. In today experiments, the spatial properties of entangled photons are recorded by means of complex and slow setups that include either the motorized scanning of single-pixel single-photon detectors, such as Photo-Multiplier Tubes (PMT) or Silicon Photo- Multipliers (SiPM), or the use of low frame rate intensified CCD cameras. CMOS arrays of Single Photon Avalanche Diodes (SPAD) represent a relatively recent technology that may lead to simpler setups and faster acquisition. They are spatially- and time-resolved single-photon detectors, i.e. they can provide the position within the array and the time of arrival of every detected photon with <100 ps resolution. SUPERTWIN is a European H2020 project aiming at developing the technological building blocks (emitter, detector and system) for a new, all solid-state quantum microscope system exploiting entangled photons to overcome the Rayleigh limit, targeting a resolution of 40nm. This work provides the measurement results of the 2nd order cross-correlation function relative to a flux of entangled photon pairs acquired with a fully digital 8×16 pixel SPAD array in CMOS technology. The limitations for application in quantum optics of the employed architecture and of other solutions in the literature will be analyzed, with emphasis on crosstalk. Then, the specifications for a dedicated detector will be given, paving the way for future implementations of 100kpixel Quantum Image Sensors.
Correlations between photons are interesting for a number of applications and concepts in metrology in particular for resolution improvements in different methods of quantum imaging. Since Fock-states of N-photons of wavelength lambda in interference schemes acquire N-times the phase shift of single photons these states can appear as if they had a de Broglie wavelength of lambda/N. A biphoton beam diffracted at a blazed grating shows this reduced de Broglie wavelength. This experiment can be seen as a purification of biphotons of a certain correlation strength on the one hand. On the other hand the evaluation of the one-photon and two-photon rate distributions in the Fraunhofer far field of the grating allows for an analysis of the spatial correlation between the photons. An experimental demonstration of these ideas tested for a biphoton beam generated by parametric down conversion (PDC) is reported. We demonstrate in addition that the existence of higher order spatial modes is important to observe strong spatial correlations and to observe the photonic de Broglie wavelength of lambda/2 for biphotons.
Summary form only given. We demonstrate a proof-of-principle experiment of quantum lithography utilizing parametric down-converted photons and a transmission grating, and show that the diffraction of a multiphoton state can be also explained by the concept of the photonic de Broglie wave. Pairs of frequency-degenerate photons were collinearly generated by spontaneous parametric down-conversion (SPDC) in a 5 mm long KNbO/sub 3/ (KN) crystal pumped by the second harmonic light of a single longitudinal mode Ti:sapphire laser operating at 861.5 nm. The photon pairs were diffracted by a transmission grating (slit width: 125 /spl mu/m, period: 250 /spl mu/m), placed just after the KN crystal. In this geometry, each photon pair passes together through one of the grating slits. By rotating a mirror, we recorded spatial diffraction-interference patterns at a two-photon detector consisting of two avalanche photodiodes. For comparison, we also observed diffraction-interference patterns of chaotic light from a tungsten lamp using the same apparatus.