Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Additional resonances for cavity-mediated laser cooling

Олег Ким, Almut Beige

Published Jul 28, 2013• 0 citations
OpenAlex

Related papers

Numerical study of cavity-mediated laser cooling of a trapped two-level atom

Faiz Mohammed Khan, Abdulaziz Aljalal

•Jan 1, 2025•0 citations

New Physical Mechanisms in Laser Cooling

Yvan Castin, K. Mφlmer, Jean Dalibard +1 more

Laser Spectroscopy•Jan 1, 1989•2 citations

Mollow triplet for cavity-mediated laser cooling

Oleg Kim, Almut Beige

Here we analyze cavity-mediated laser cooling for an experimental setup with an external trap which strongly confines the motion of a particle in the direction of the cavity axis. It is shown that the stationary-state phonon number exhibits three sharp minima as a function of the atom-cavity detuning due to a direct atom-phonon-photon coupling term in the system Hamiltonian. These resonances have the same origin as the Mollow triplet in the resonance fluorescence of a laser-driven atomic system. It is shown that a laser-Rabi-frequency-dependent atom-cavity detuning yields the lowest stationary-state phonon number for a wide range of experimental parameters.

arXiv:1307.7400•Physical Review A•Nov 15, 2013•5 citations

Laser Cooling by Stimulated Emission

Robinjeet Singh, Sai Vinjanampathy, Petr M. Anisimov +2 more

Bulletin of the American Physical Society•Jun 10, 2015•0 citations

Rate-equation approach to cavity-mediated laser cooling

Tony Blake, Andreas Kurcz, Almut Beige

The cooling rate for cavity-mediated laser cooling scales as the Lamb-Dicke parameter $\ensuremath{\eta}$ squared. A proper analysis of the cooling process hence needs to take terms up to ${\ensuremath{\eta}}^{2}$ in the system dynamics into account. In this paper, we present such an analysis for a standard scenario of cavity-mediated laser cooling with $\ensuremath{\eta}\ensuremath{\ll}1$. Our results confirm that there are many similarities between ordinary and cavity-mediated laser cooling. However, for a weakly confined particle inside a strongly coupled cavity, which is the most interesting case for the cooling of molecules, numerical results indicate that more detailed calculations are needed to model the cooling process accurately.

arXiv:1202.2992•Physical Review A•Jul 23, 2012•7 citations

A quantum approach to cavity mediated laser cooling

Tony Blake

Cavity-mediated cooling has the potential to become one of the most efficient techniques to cool molecular species down to very low temperatures. This thesis studies the use of rate equations to analyse the cooling process in such systems. In particular the master equation is used to find rate equations that can determine the rate of change of phonons in the system. The general idea behind cavity cooling is the continuous conversion of phonons into cavity photons. While there is no spontaneous emission and decay rate associated with the concept of phonons, photons are created after a change in the phonon number has occurred and can then leak out through the cavity mirrors easily. Hence the conversion of phonons into photons can result in the constant removal of phonon energy from the system. In this thesis we compare cavity mediated cooling with single particle laser cooling. It is shown that cavity cooling is essentially the same as ordinary laser cooling. This is done by calculating the stationary state phonon number mss and the cooling rate y as a function of the system parameters. For example, when the trap phonon frequency υ is either much larger or much smaller than the cavity decay rate k , the minimum stationary state phonon number scales as k²/16v² (strong confinement regime) and as k/4 (weak confinement regime), respectively. Replacing k with Ѓ yields the steady states associated with ordinary laser cooling.

•Sep 1, 2011•0 citations
Here we analyze cavity-mediated laser cooling for an experimental setup with an external trap which strongly confines the motion of a particle in the direction of the cavity axis. It is shown that the stationary-state phonon number exhibits three sharp minima as a function of the atom-cavity detuning due to a direct atom-phonon-photon coupling term in the system Hamiltonian. These resonances have the same origin as the Mollow triplet in the resonance fluorescence of a laser-driven atomic system. It is shown that a laser-Rabi-frequency-dependent atom-cavity detuning yields the lowest stationary-state phonon number for a wide range of experimental parameters.
The cooling rate for cavity-mediated laser cooling scales as the Lamb-Dicke parameter $\ensuremath{\eta}$ squared. A proper analysis of the cooling process hence needs to take terms up to ${\ensuremath{\eta}}^{2}$ in the system dynamics into account. In this paper, we present such an analysis for a standard scenario of cavity-mediated laser cooling with $\ensuremath{\eta}\ensuremath{\ll}1$. Our results confirm that there are many similarities between ordinary and cavity-mediated laser cooling. However, for a weakly confined particle inside a strongly coupled cavity, which is the most interesting case for the cooling of molecules, numerical results indicate that more detailed calculations are needed to model the cooling process accurately.
Cavity-mediated cooling has the potential to become one of the most efficient techniques to cool molecular species down to very low temperatures. This thesis studies the use of rate equations to analyse the cooling process in such systems. In particular the master equation is used to find rate equations that can determine the rate of change of phonons in the system. The general idea behind cavity cooling is the continuous conversion of phonons into cavity photons. While there is no spontaneous emission and decay rate associated with the concept of phonons, photons are created after a change in the phonon number has occurred and can then leak out through the cavity mirrors easily. Hence the conversion of phonons into photons can result in the constant removal of phonon energy from the system. In this thesis we compare cavity mediated cooling with single particle laser cooling. It is shown that cavity cooling is essentially the same as ordinary laser cooling. This is done by calculating the stationary state phonon number mss and the cooling rate y as a function of the system parameters. For example, when the trap phonon frequency υ is either much larger or much smaller than the cavity decay rate k , the minimum stationary state phonon number scales as k²/16v² (strong confinement regime) and as k/4 (weak confinement regime), respectively. Replacing k with Ѓ yields the steady states associated with ordinary laser cooling.