Optimisation of a compact cold-atoms interferometer for gravimetry

Clemens Rammeloo

Published Jul 1, 2018• 1 citation
OpenAlex

Abstract

The work presented in this thesis focusses on the development of a transportable atom-interferometry experiment and a compact fibre laser system towards precision measurements of gravitational acceleration. Interference fringes are shown with clouds of cold 87Rb atoms using co-propagating laser beams to drive stimulated Raman transitions. This is demonstrated both inside and outside of laboratory environments for which an integrated and transportable experiment is constructed. Further improvements are presented that enable the generation of clouds containing 1.7 · 108 atoms at a rate of 2.5 Hz and having a temperature of (7 ± 1) µK. This is largely due to the development of a compact laser system based on all-fibre coupled components. It is demonstrated that the laser system designed here can achieve fast frequency sweeps over 1.8 GHz within 2 ms, making it widely applicable in compact atom-interferometry experiments with rubidium atoms. This is shown by creating a Mach–Zehnder type interferometer with counter-propagating Raman beams, thus enabling measurements of gravitational acceleration. Since the laser system uses only two lasers and one fibre amplifier, a significant reduction in size is achieved, as well as a decrease in the total power consumption of the overall experiment by a third to (162 ± 7) W.

Related papers

Construction of a Rubidium Fountain Atomic Interferometer for Gravity Gradiometry

JN Tinsley

Atomic interferometry is a highly precise metrological technique of interest to both fundamental and applied physics. One field in which atomic interferometry is of particular interest is gravimetry, where instruments based upon the controlled manipulation of atomic states have superseded the performance of classical devices. In such devices, a standing wave derived from laser beams with well-defined phase difference are used to impart momentum to atoms undergoing free fall, generating spatial superpositions along the axis of gravity, before returning the atoms to an overlapped final state for recombination. This thesis presents the design and experimental progress towards a gravity gradiometer based upon the interference of rubidium-87 atoms, cooled and launched in a fountain configuration. The fountain is leveraged from a decommissioned frequency standard, which has been re-purposed and redesigned for use as a combined absolute gravimeter and gravity gradiometer package. It is capable of loading 100 billion atoms in 100 ms and then cooling and launching these atoms in a moving molasses configuration, with a final temperature of 5 μK. Furthermore, the process can be quickly repeated, with a second cloud subsequently launched, reaching its apogee at the same time as the first cloud, allowing for the possibility of simultaneous measurement at different heights and, in the future, the inference of the gravity gradient. Control of the fountain is provided by a stable and miniaturised optical setup, allowing for use with a future transportable or field-based device. A Raman beam system to perform the interferometry sequence has been constructed and characterised, likewise designed in a minaturised and stable manner. The Raman beams simultaneously generated Ramsey interference fringes on two independent clouds of atoms -- one launched to a height of 0.7 m and the other to 1 m. Such fringes were clearly observable after 200 ms of evolution time. Mach-Zehnder interference fringes were also demonstrated for dropped and launched atoms, providing the capability for gravimetric measurements to be made once the system has been fully characterised. The principle causes of noise in the Mach-Zehnder cases were identified as arriving from a lack of atoms and the phase noise of the Raman beams. To overcome these challenges, a new Raman beam system has been preliminary designed and tested and a new iteration of the fountain, moving towards quantum degeneracy, has been planned.

•Jan 1, 2019•2 citations

Construction of a portable platform for cold atom interferometry

Jonathan Ian Malcolm

This thesis details the construction of a portable platform for cold atom experiments, as part of the European iSense project. This culminated in the demonstration of a working portable cold atom interferometer to the praise of the EC and reviewers during the final project meeting. Reductions in the size, weight and power consumption of all the crucial components for a cold atom system such as lasers, optics, magnetic field generation and electronics have been realised. These novel components have been integrated into a portable device that has been transported and operated by just two people. The completed device weighs 63 kg and uses 240 W power in a volume of just 61.1 litres. The system has generated a cloud of (6.7±0.7)x 10\(^6\) rubidium-87 atoms at a temperature of 4.4 μK in 2 seconds using a mirror-MOT setup. The device has successfully performed atom interferometry in the form of a Ramsey interferometer both at the University of Birmingham, UK and also at an office in Brussels, BE after a journey of 570 km. A measurement of the hyperfine splitting of the ground state of rubidium-87 was performed and gives an uncertainty of \(\delta\)\(\omega\)/\(\omega\) = 5.2 × 10\(^-\)\(^7\). The theoretical limit of the sensitivity to gravity of the iSense system is 3.9 μGal/√Hz.

•Jul 1, 2016•6 citations

Development and characterisation of a cold atom interferometer with composite and optimal control pulse implementation

Joel Abraham

Developments in the precise control of quantum systems have led to advances in both fundamental research and emerging technologies in areas including quantum sensing and computation. One particularly useful application is atom interferometry, which uses laser pulses to split, redirect, and recombine atomic wavepackets, enabling precision measurements of inertial effects. This thesis presents the construction and characterisation of a compact cold atom interferometer, to meet the longer-term aim of developing an atomic gyroscope. We detail the setup of a rubidium-85 Magneto-Optical Trap (MOT) and the development of a laser to perform Raman transitions across the hyperfine Rb-85 levels. We then demonstrate and characterise the coherent manipulation of the atomic state of the rubidium as well as atom-interferometric fringes, in a Doppler-insensitive configuration. Systematic errors can degrade the performance of laser pulse interactions with cold atoms by reducing the fidelity of the atom–light interactions. In this thesis, we investigate the implementation of composite pulses and optimal control pulses, which use pulses with varying phase sequences and durations to mitigate against experimental inhomogeneities. We also show that phase modulators can introduce distortions in both the applied laser phase and the Raman modulation amplitude, which can in turn degrade pulse performance. To address this, we develop a compensation protocol that corrects for these non-linearities and demonstrate that it leads to a further improvement in pulse fidelity, for the Waltz and Knill composite pulses. Applying this protocol to the rotary echo sequence led to Rabi oscillations that could last 4 times longer, compared to the uncalibrated IQ modulator. Although an optimal control inversion pulse showed more resilience to the IQ modulator distortions, the Mach-Zehnder interferometer sequence was more susceptible to them. It was demonstrated that compensating for IQ modulator non-linearities improved the optimised fringe signal-to-noise ratio, and reduced the phase-offset error by a factor of 2.4.

•Oct 22, 2026•0 citations

A compact laser system for a portable atom interferometry gravimeter

Qin Luo, Heng Zhang, Ke Zhang +4 more

A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.

Review of Scientific Instruments•Apr 1, 2019•43 citations

Measurement of Local Gravity via a Cold Atom Interferometer

Lin Zhou, Zongyuan Xiong, Weiyou Yang +6 more

We demonstrate a precision measurement of local gravity acceleration g in Wuhan by a compact cold atom interferometer. The atom interferometer is in vertical Mach—Zehnder configuration realized using a π/2 - π - π/2 Raman pulse sequence. Cold atoms were prepared in a magneto-optical trap, launched upward to form an atom fountain, and then coherently manipulated to interfere by stimulated Raman transition. Population signal vs Raman laser phase was recorded as interference fringes, and the local gravity was deduced from the interference signal. We have obtained a resolution of 7 × 10 −9 g after an integration time of 236s under the best vibrational environment conditions. The absolute g value was derived from the chirp rate with a difference of 1.5 × 10 −7 g compared to the gravity reference value. The tidal phenomenon was observed by continuously monitoring the local gravity over 123 h.

Chinese Physics Letters•Jan 1, 2011•56 citations

Development of a transportable cold atom gradiometer

Andrew Hinton

This work describes the technology developed for the transportable gravity gradiometer, ''GGtop", constructed at the University of Birmingham. The device aims to simultaneously interrogate two physically separated, free-falling cold atom clouds using the technique of Raman interferometry to perform differential gravity measurements. Such a technique will suppress common-mode noise sources, such as vibrations, that otherwise limit classical gravimeters and cold atom interferometers based on single-cloud measurements. The technique is expected to improve speed and sensitivity for field measurements greatly. \nUsing a combination of commercially available components and novel designs, intended to enhance portability and robustness, allowed for demonstration of atomic interference with the apparatus via Ramsey's method of separated oscillatory fields. The achieved fringe contrast of ~2%, defined as the difference in the number of atoms detected in IF = 2>, was limited by drifts stemming from some of the novel designs which prompted continued optimisation of the underpinning subsystems. To address performance issues parts of the experiment were redesigned with the goal of improving reliability at the expense of some portability. Using the retrofitted experiment, interference was once again achieved with fitted fringe spacing of 134.7±2.0 uS in good agreement with the 133.9 uS defined by the experimental control. A factor of 10 improvement in contrast was found with the central fringe demonstrating 18% of the atoms detected in the IF = 2> state when normalised to the total 3D MOT number. The 3.71 ± 0.01 kHz fitted linewidth of the central fringe gives a frequency uncertainty of 5.43 ± 0.01 x 10 - 7. This result leaves the experiment in a good position to begin making measurements of gravity.

•Dec 1, 2016•1 citation
The work presented in this thesis focusses on the development of a transportable atom-interferometry experiment and a compact fibre laser system towards precision measurements of gravitational acceleration. Interference fringes are shown with clouds of cold 87Rb atoms using co-propagating laser beams to drive stimulated Raman transitions. This is demonstrated both inside and outside of laboratory environments for which an integrated and transportable experiment is constructed. Further improvements are presented that enable the generation of clouds containing 1.7 · 108 atoms at a rate of 2.5 Hz and having a temperature of (7 ± 1) µK. This is largely due to the development of a compact laser system based on all-fibre coupled components. It is demonstrated that the laser system designed here can achieve fast frequency sweeps over 1.8 GHz within 2 ms, making it widely applicable in compact atom-interferometry experiments with rubidium atoms. This is shown by creating a Mach–Zehnder type interferometer with counter-propagating Raman beams, thus enabling measurements of gravitational acceleration. Since the laser system uses only two lasers and one fibre amplifier, a significant reduction in size is achieved, as well as a decrease in the total power consumption of the overall experiment by a third to (162 ± 7) W.
Atomic interferometry is a highly precise metrological technique of interest to both fundamental and applied physics. One field in which atomic interferometry is of particular interest is gravimetry, where instruments based upon the controlled manipulation of atomic states have superseded the performance of classical devices. In such devices, a standing wave derived from laser beams with well-defined phase difference are used to impart momentum to atoms undergoing free fall, generating spatial superpositions along the axis of gravity, before returning the atoms to an overlapped final state for recombination. This thesis presents the design and experimental progress towards a gravity gradiometer based upon the interference of rubidium-87 atoms, cooled and launched in a fountain configuration. The fountain is leveraged from a decommissioned frequency standard, which has been re-purposed and redesigned for use as a combined absolute gravimeter and gravity gradiometer package. It is capable of loading 100 billion atoms in 100 ms and then cooling and launching these atoms in a moving molasses configuration, with a final temperature of 5 μK. Furthermore, the process can be quickly repeated, with a second cloud subsequently launched, reaching its apogee at the same time as the first cloud, allowing for the possibility of simultaneous measurement at different heights and, in the future, the inference of the gravity gradient. Control of the fountain is provided by a stable and miniaturised optical setup, allowing for use with a future transportable or field-based device. A Raman beam system to perform the interferometry sequence has been constructed and characterised, likewise designed in a minaturised and stable manner. The Raman beams simultaneously generated Ramsey interference fringes on two independent clouds of atoms -- one launched to a height of 0.7 m and the other to 1 m. Such fringes were clearly observable after 200 ms of evolution time. Mach-Zehnder interference fringes were also demonstrated for dropped and launched atoms, providing the capability for gravimetric measurements to be made once the system has been fully characterised. The principle causes of noise in the Mach-Zehnder cases were identified as arriving from a lack of atoms and the phase noise of the Raman beams. To overcome these challenges, a new Raman beam system has been preliminary designed and tested and a new iteration of the fountain, moving towards quantum degeneracy, has been planned.
This thesis details the construction of a portable platform for cold atom experiments, as part of the European iSense project. This culminated in the demonstration of a working portable cold atom interferometer to the praise of the EC and reviewers during the final project meeting. Reductions in the size, weight and power consumption of all the crucial components for a cold atom system such as lasers, optics, magnetic field generation and electronics have been realised. These novel components have been integrated into a portable device that has been transported and operated by just two people. The completed device weighs 63 kg and uses 240 W power in a volume of just 61.1 litres. The system has generated a cloud of (6.7±0.7)x 106^66 rubidium-87 atoms at a temperature of 4.4 μK in 2 seconds using a mirror-MOT setup. The device has successfully performed atom interferometry in the form of a Ramsey interferometer both at the University of Birmingham, UK and also at an office in Brussels, BE after a journey of 570 km. A measurement of the hyperfine splitting of the ground state of rubidium-87 was performed and gives an uncertainty of δ\deltaδω\omegaω/ω\omegaω = 5.2 × 10−^-−7^77. The theoretical limit of the sensitivity to gravity of the iSense system is 3.9 μGal/√Hz.
Developments in the precise control of quantum systems have led to advances in both fundamental research and emerging technologies in areas including quantum sensing and computation. One particularly useful application is atom interferometry, which uses laser pulses to split, redirect, and recombine atomic wavepackets, enabling precision measurements of inertial effects. This thesis presents the construction and characterisation of a compact cold atom interferometer, to meet the longer-term aim of developing an atomic gyroscope. We detail the setup of a rubidium-85 Magneto-Optical Trap (MOT) and the development of a laser to perform Raman transitions across the hyperfine Rb-85 levels. We then demonstrate and characterise the coherent manipulation of the atomic state of the rubidium as well as atom-interferometric fringes, in a Doppler-insensitive configuration. Systematic errors can degrade the performance of laser pulse interactions with cold atoms by reducing the fidelity of the atom–light interactions. In this thesis, we investigate the implementation of composite pulses and optimal control pulses, which use pulses with varying phase sequences and durations to mitigate against experimental inhomogeneities. We also show that phase modulators can introduce distortions in both the applied laser phase and the Raman modulation amplitude, which can in turn degrade pulse performance. To address this, we develop a compensation protocol that corrects for these non-linearities and demonstrate that it leads to a further improvement in pulse fidelity, for the Waltz and Knill composite pulses. Applying this protocol to the rotary echo sequence led to Rabi oscillations that could last 4 times longer, compared to the uncalibrated IQ modulator. Although an optimal control inversion pulse showed more resilience to the IQ modulator distortions, the Mach-Zehnder interferometer sequence was more susceptible to them. It was demonstrated that compensating for IQ modulator non-linearities improved the optimised fringe signal-to-noise ratio, and reduced the phase-offset error by a factor of 2.4.
A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.
We demonstrate a precision measurement of local gravity acceleration g in Wuhan by a compact cold atom interferometer. The atom interferometer is in vertical Mach—Zehnder configuration realized using a π/2 - π - π/2 Raman pulse sequence. Cold atoms were prepared in a magneto-optical trap, launched upward to form an atom fountain, and then coherently manipulated to interfere by stimulated Raman transition. Population signal vs Raman laser phase was recorded as interference fringes, and the local gravity was deduced from the interference signal. We have obtained a resolution of 7 × 10 −9 g after an integration time of 236s under the best vibrational environment conditions. The absolute g value was derived from the chirp rate with a difference of 1.5 × 10 −7 g compared to the gravity reference value. The tidal phenomenon was observed by continuously monitoring the local gravity over 123 h.
This work describes the technology developed for the transportable gravity gradiometer, ''GGtop", constructed at the University of Birmingham. The device aims to simultaneously interrogate two physically separated, free-falling cold atom clouds using the technique of Raman interferometry to perform differential gravity measurements. Such a technique will suppress common-mode noise sources, such as vibrations, that otherwise limit classical gravimeters and cold atom interferometers based on single-cloud measurements. The technique is expected to improve speed and sensitivity for field measurements greatly. \nUsing a combination of commercially available components and novel designs, intended to enhance portability and robustness, allowed for demonstration of atomic interference with the apparatus via Ramsey's method of separated oscillatory fields. The achieved fringe contrast of ~2%, defined as the difference in the number of atoms detected in IF = 2>, was limited by drifts stemming from some of the novel designs which prompted continued optimisation of the underpinning subsystems. To address performance issues parts of the experiment were redesigned with the goal of improving reliability at the expense of some portability. Using the retrofitted experiment, interference was once again achieved with fitted fringe spacing of 134.7±2.0 uS in good agreement with the 133.9 uS defined by the experimental control. A factor of 10 improvement in contrast was found with the central fringe demonstrating 18% of the atoms detected in the IF = 2> state when normalised to the total 3D MOT number. The 3.71 ± 0.01 kHz fitted linewidth of the central fringe gives a frequency uncertainty of 5.43 ± 0.01 x 10 - 7. This result leaves the experiment in a good position to begin making measurements of gravity.