Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Two-mode quantum interferometry with a single-mode Fock state and parity detection

Shuai Wang, Yao‐Ting Wang, Liang-Jun Zhai, Lijian Zhang

Published Apr 9, 2018• 7 citations
Publisher

Abstract

We derive a general expression of the expectation value of the parity operator in a Mach–Zehnder interferometer with a Fock state in one input port and an arbitrary state in the other input. We obtain the quantum Crámer–Rao bound via the error propagation method from parity detection for the phase shift around zero. In addition, for an arbitrary state with the same mean photon number, our results show that the same phase resolution and the same phase uncertainty can be obtained for the phase shift around zero. That is to say, when a Mach–Zehnder interferometer is powered by a Fock state into one input port, all quantum states with same mean photon number at the other input may have the same performance in the phase estimation via parity detection. As some specific applications, we consider the arbitrary state being a Fock state, a coherent state, and a squeezed-vacuum state.

DOI
10.1364/josab.35.001046

Related papers

Optical enhanced interferometry with two-mode squeezed twin-Fock states and parity detection*

Li-Li Hou, Shuai Wang, Xuefen Xu

We theoretically investigate the quantum enhanced metrology using two-mode squeezed twin-Fock states and parity detection. Our results indicate that, for a given initial squeezing parameter, compared with the two-mode squeezed vacuum state, both phase sensitivity and resolution can be enhanced when the two-mode squeezed twin-Fock state is considered as an input state of a Mach–Zehnder interferometer. Within a constraint on the total photon number, although the two-mode squeezed vacuum state gives the better phase sensitivity when the phase shift φ to be estimated approaches to zero, the phase sensitivity offered by these non-Gaussian entangled Gaussian states is relatively stable with respect to the phase shift itself. When the phase shift slightly deviates from φ = 0, the phase sensitivity can be still enhanced by the two-mode squeezed twin-Fock state over a broad range of the total mean photon number where the phase uncertainty is still below the quantum standard noise limit. Finally, we numerically prove that the quantum Cramér–Rao bound can be approached with the parity detection.

Chinese Physics B•Jan 7, 2020•11 citations

Quantum optical interferometry via general photon-subtracted two-mode squeezed states*

Li-Li Hou, Jianzhong Xue, Yongxing Sui +1 more

We investigate the sensitivity of phase estimation in a Mach–Zehnder interferometer with photon-subtracted two-mode squeezed vacuum states. Our results show that, for given initial squeezing parameter, both symmetric and asymmetric photon subtractions can further improve the quantum Cramér–Rao bound (i.e., the ultimate phase sensitivity), especially for single-mode photon subtraction. On the other hand, the quantum Cramér–Rao bound can be reached by parity detection for symmetric photon-subtracted two-mode squeezed vacuum states at particular values of the phase shift, but it is not valid for asymmetric photon-subtracted two-mode squeezed vacuum states. In addition, compared with the two-mode squeezed vacuum state, the phase sensitivity via parity detection with asymmetric photon-subtracted two-mode squeezed vacuum states will be getting worse. Thus, parity detection may not always be the optimal detection scheme for nonclassical states of light when they are considered as the interferometer states.

Chinese Physics B•Aug 6, 2019•7 citations

Quantum interferometry via a coherent state mixed with a squeezed number state

Li-Li Hou, Yongxing Sui, Shuai Wang +1 more

We theoretically investigate the phase sensitivity with parity measurement on a Mach–Zehnder interferometer with a coherent state combined with a squeezed number state. Within a constraint on the total mean photon number, we find, via parity measurement, that the mixing of a coherent state and squeezed number state can give better phase sensitivity than mixing a coherent state and squeezed vacuum state when the phase shift deviates from the optimal phase φ =0. In addition, we show that the classical Fisher information for parity measurement saturates the quantum Fisher information when the phase shift approaches to zero. Thus, the quantum Cramér–Rao bound can be reached via the parity measurement in the case of φ =0.

Chinese Physics B•Apr 1, 2019•9 citations

Quantum optical interferometry via the photon-added two-mode squeezed vacuum states

Yi Ouyang, Shuai Wang, Lijian Zhang

We investigate the sensitivity and resolution of phase estimation in a Mach–Zehnder interferometer with photon-added two-mode squeezed vacuum states (PA-TMSVS) with a photon-number parity measurement scheme. Our results indicate that, when the phase to be estimated is small, the PA-TMSVS offers an improved phase resolution over both the two-mode squeezed vacuum and the photon-subtracted two-mode squeezed vacuum for a given initial squeezing level. In addition, we study the behavior of the quantum Fisher information of the PA-TMSVS, and show that the optimum phase uncertainty predicted by the corresponding Cramer–Rao bound can be achieved with a parity measurement.

Journal of the Optical Society of America B•Jun 3, 2016•70 citations

Application of photon-added two-mode squeezed vacuum states to phase estimation based on Mach-Zehnder interferometer

Shuai Wang, Yongxing Sui, Xiang-Guo Meng

Quantum metrology is to estimate accurately the value of an unknown parameter with the assistance of the quantum effects, in order to break through the standard quantum limit, even reach the Heisenberg limit. In this work, we study the performance of a general photon-added two-mode squeezed vacuum state that is taken as a detection state of a Mach-Zehnder interferometer. Based on quantum Fisher information, within the constraint on the total mean photon number, symmetric and asymmetric photon addition cannot improve the ultimate phase sensitivity. However, for a given initial squeezing parameter, on this occasion, the symmetric and asymmetric photon addition can improve the ultimate phase sensitivity. Compared with the asymmetric photon-added two-mode squeezed vacuum state, the symmetric one can well improve the ultimate phase sensitivity. This may be because it is always better to implement the symmetric photon addition rather than the asymmetric one in order to increase the mean photon number of the resulting state. On the other hand, via parity detection, the symmetric and asymmetric photon-added two-mode squeezed vacuum state can indeed improve the phase sensitivity of a Mach-Zehnder interferometer for a given initial squeezing parameter. Based on the parity detection, within a constraint on the mean photon number, although the two-mode squeezed vacuum state can give the better phase sensitivity at the optimal phase shift (φ = 0), the phase sensitivity offered by the symmetric and asymmetric photon-added two-mode squeezed vacuum states are both more stable around φ = 0 than by the two-mode squeezed vacuum state. In addition, we show that for the symmetric photon-added two-mode squeezed vacuum state, parity detection is an optimal detection only when the optimal phase shift approaches to zero. When the phase shift slightly deviates from zero, the parity detection is not an optimal detection scheme. Finally, for all values of the phase shift, our results also clearly show that the parity detection is not an optimal detection scheme for the asymmetric photon-added two-mode squeezed vacuum state serving as an interferometer state.

Acta Physica Sinica•Jan 1, 2020•0 citations

Phase estimation of phase shifts in two arms for an SU(1,1) interferometer with coherent and squeezed vacuum states

Qian-Kun Gong, Dong Li, Chun-Hua Yuan +2 more

We theoretically present the quantum Cramér-Rao bounds (QCRB) of an SU(1,1) interferometer for Gaussian states input with and without the internal photonic losses. The phase shifts in the single arm and in the double arms are studied and the corresponding analytical expressions of quantum Fisher information with Gaussian input states are presented. Different from the traditional Mach-Zehnder interferometer, the QCRB of single arm case is slightly higher or lower than that of double arms case depending on the input states. With a fixed mean photon number and for pure Gaussian state input, the optimal sensitivity is achieved with a squeezed vacuum input in one mode and the vacuum input in the other. We compare the QCRB with the standard quantum limit and Heisenberg limit. In the case of small internal losses the QCRB can beat the standard quantum limit.

arXiv:1608.00389•Chinese Physics B•Aug 1, 2017•26 citations
We derive a general expression of the expectation value of the parity operator in a Mach–Zehnder interferometer with a Fock state in one input port and an arbitrary state in the other input. We obtain the quantum Crámer–Rao bound via the error propagation method from parity detection for the phase shift around zero. In addition, for an arbitrary state with the same mean photon number, our results show that the same phase resolution and the same phase uncertainty can be obtained for the phase shift around zero. That is to say, when a Mach–Zehnder interferometer is powered by a Fock state into one input port, all quantum states with same mean photon number at the other input may have the same performance in the phase estimation via parity detection. As some specific applications, we consider the arbitrary state being a Fock state, a coherent state, and a squeezed-vacuum state.
We theoretically investigate the quantum enhanced metrology using two-mode squeezed twin-Fock states and parity detection. Our results indicate that, for a given initial squeezing parameter, compared with the two-mode squeezed vacuum state, both phase sensitivity and resolution can be enhanced when the two-mode squeezed twin-Fock state is considered as an input state of a Mach–Zehnder interferometer. Within a constraint on the total photon number, although the two-mode squeezed vacuum state gives the better phase sensitivity when the phase shift φ to be estimated approaches to zero, the phase sensitivity offered by these non-Gaussian entangled Gaussian states is relatively stable with respect to the phase shift itself. When the phase shift slightly deviates from φ = 0, the phase sensitivity can be still enhanced by the two-mode squeezed twin-Fock state over a broad range of the total mean photon number where the phase uncertainty is still below the quantum standard noise limit. Finally, we numerically prove that the quantum Cramér–Rao bound can be approached with the parity detection.
We investigate the sensitivity of phase estimation in a Mach–Zehnder interferometer with photon-subtracted two-mode squeezed vacuum states. Our results show that, for given initial squeezing parameter, both symmetric and asymmetric photon subtractions can further improve the quantum Cramér–Rao bound (i.e., the ultimate phase sensitivity), especially for single-mode photon subtraction. On the other hand, the quantum Cramér–Rao bound can be reached by parity detection for symmetric photon-subtracted two-mode squeezed vacuum states at particular values of the phase shift, but it is not valid for asymmetric photon-subtracted two-mode squeezed vacuum states. In addition, compared with the two-mode squeezed vacuum state, the phase sensitivity via parity detection with asymmetric photon-subtracted two-mode squeezed vacuum states will be getting worse. Thus, parity detection may not always be the optimal detection scheme for nonclassical states of light when they are considered as the interferometer states.
We theoretically investigate the phase sensitivity with parity measurement on a Mach–Zehnder interferometer with a coherent state combined with a squeezed number state. Within a constraint on the total mean photon number, we find, via parity measurement, that the mixing of a coherent state and squeezed number state can give better phase sensitivity than mixing a coherent state and squeezed vacuum state when the phase shift deviates from the optimal phase φ =0. In addition, we show that the classical Fisher information for parity measurement saturates the quantum Fisher information when the phase shift approaches to zero. Thus, the quantum Cramér–Rao bound can be reached via the parity measurement in the case of φ =0.
We investigate the sensitivity and resolution of phase estimation in a Mach–Zehnder interferometer with photon-added two-mode squeezed vacuum states (PA-TMSVS) with a photon-number parity measurement scheme. Our results indicate that, when the phase to be estimated is small, the PA-TMSVS offers an improved phase resolution over both the two-mode squeezed vacuum and the photon-subtracted two-mode squeezed vacuum for a given initial squeezing level. In addition, we study the behavior of the quantum Fisher information of the PA-TMSVS, and show that the optimum phase uncertainty predicted by the corresponding Cramer–Rao bound can be achieved with a parity measurement.
Quantum metrology is to estimate accurately the value of an unknown parameter with the assistance of the quantum effects, in order to break through the standard quantum limit, even reach the Heisenberg limit. In this work, we study the performance of a general photon-added two-mode squeezed vacuum state that is taken as a detection state of a Mach-Zehnder interferometer. Based on quantum Fisher information, within the constraint on the total mean photon number, symmetric and asymmetric photon addition cannot improve the ultimate phase sensitivity. However, for a given initial squeezing parameter, on this occasion, the symmetric and asymmetric photon addition can improve the ultimate phase sensitivity. Compared with the asymmetric photon-added two-mode squeezed vacuum state, the symmetric one can well improve the ultimate phase sensitivity. This may be because it is always better to implement the symmetric photon addition rather than the asymmetric one in order to increase the mean photon number of the resulting state. On the other hand, via parity detection, the symmetric and asymmetric photon-added two-mode squeezed vacuum state can indeed improve the phase sensitivity of a Mach-Zehnder interferometer for a given initial squeezing parameter. Based on the parity detection, within a constraint on the mean photon number, although the two-mode squeezed vacuum state can give the better phase sensitivity at the optimal phase shift (φ = 0), the phase sensitivity offered by the symmetric and asymmetric photon-added two-mode squeezed vacuum states are both more stable around φ = 0 than by the two-mode squeezed vacuum state. In addition, we show that for the symmetric photon-added two-mode squeezed vacuum state, parity detection is an optimal detection only when the optimal phase shift approaches to zero. When the phase shift slightly deviates from zero, the parity detection is not an optimal detection scheme. Finally, for all values of the phase shift, our results also clearly show that the parity detection is not an optimal detection scheme for the asymmetric photon-added two-mode squeezed vacuum state serving as an interferometer state.
We theoretically present the quantum Cramér-Rao bounds (QCRB) of an SU(1,1) interferometer for Gaussian states input with and without the internal photonic losses. The phase shifts in the single arm and in the double arms are studied and the corresponding analytical expressions of quantum Fisher information with Gaussian input states are presented. Different from the traditional Mach-Zehnder interferometer, the QCRB of single arm case is slightly higher or lower than that of double arms case depending on the input states. With a fixed mean photon number and for pure Gaussian state input, the optimal sensitivity is achieved with a squeezed vacuum input in one mode and the vacuum input in the other. We compare the QCRB with the standard quantum limit and Heisenberg limit. In the case of small internal losses the QCRB can beat the standard quantum limit.