Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Realization of the Resonant Cold-Electron Bolometer With a Kinetic Inductance Nanofilter for Multichroic Pixels

L. S. Kuzmin, Anton S. Mukhin, Alexander V. Chiginev

Published Mar 6, 2018• 3 citations
Publisher

Abstract

A novel type of the resonant cold-electron bolometer (RCEB) has been realized for multichroic pixels. The internal resonance is organized by a kinetic inductance of the NbN superconducting nanostrip and a capacitance of the superconductor-insulator-normal (SIN) tunnel junctions. The basic idea of a multichroic system is to combine a wideband antenna and narrow-band RCEBs. We used a single Lambda slot with two RCEBs for 75 and 105 GHz, placed in the middle. Each RCEB included two SIN junctions with absorber connected to NbN kinetic inductance of 420 and 240 pH. SIN junctions had capacitances of 11 and 8 fF. Wave impedance of the slot antenna was near 15 Ω and resistance of the absorber was matched to this value. Matching of antenna with an external system was done by placing Si lens on the back side of a Si substrate. RF testing was done at 300 mK irradiating this chip by sweep generator from 60 to 120 GHz. The response curves showed clear resonances at 75 and 105 GHz with quality factor of 10 and 7. Kinetic inductance value was estimated at the level of 35 pH/sq. These experiments confirmed that the RCEB can be effectively used to create multiband elements.

DOI
10.1109/tasc.2018.2812827

Related papers

A Resonant Cold-Electron Bolometer With a Kinetic Inductance Nanofilter

L. S. Kuzmin

A novel type of resonant cold-electron bolometer (RCEB) is proposed. In this sensor, the internal resonance is organized by the kinetic inductance of an ultrasmall NbN superconducting nanostrip and the capacitance of the nanoscale superconductor-insulator-normal (SIN) tunnel junction. The size of kinetic inductance is about 300 times smaller than the size of geometrical inductance of the same value. This reduction of size gives an opportunity to create nanofilters with a total size considerably smaller than the wavelength. This internal resonance acts as a bandpass filter (instead of external filters) with a bandwidth of 3%-50%, something needed for radioastronomy applications. The use of NbN as Andreev contact material against escaping hot quasiparticles provides a unique opportunity to create an optimal CEB with only one SIN junction and an Andreev SN contact for thermal protection, in contrast to a classical CEB with two SIN junctions. The problem of hot quasiparticles escaping over the Andreev barrier (Δ) for Al electrode is overcome here by creating a barrier higher than quantum energy Δ > hf to have working kinetic inductance. Replacing two SIN junctions by one junction, we could use this junction of half the area to keep the same capacitive coupling. Therefore, a single-junction RCEB would have four times less area of junctions (and volume of absorber) in comparison with a two-junction RCEB and should show better noise performance due to the proportionally decreased e-ph (electron-phonon) noise component. The RCEB can be effectively used to create multiband elements that are actual tasks in submillimeter astronomy due to the benefit that comes from its ability to use co-located data, and problems with the dramatic increase of the size of the focal plane.

IEEE Transactions on Terahertz Science and Technology•Mar 25, 2014•14 citations

Capacitively Coupled Hot-Electron Nanobolometer with SIN Tunnel Junctions

L. S. Kuzmin, M. Yu. Fominsky, Alexei Kalabukhov +2 more

A capacitively coupled hot-electron nanobolometer (CC-HEB) is the simplest and most effective antenna-coupled bolometer. The bolometer consists of a small absorber connected to the superconducting antenna by tunnel junctions. The tunnel junctions used for high-frequency coupling also give perfect thermal isolation of hot electrons in the small volume of the absorber. The same tunnel junctions are used for temperature measurements and electron cooling. This bolometer does not suffer from the frequency limitations in the submillimeter range due to the high potential barrier of the tunnel junctions as does the microbolometer with Andreev mirrors (A-HEB), which is limited by the superconducting gap. Theoretical analyses show that the two-junction configuration more than doubles the sensitivity of the bolometer in current-biased mode compared to the single-junction configuration used for A-HEB. Another important advantage of CC-HEB is its simple two-layer technology for sample fabrication. Samples were fabricated with an absorber made of a bilayer of Cr and Al to match the impedance of the antenna. Electrodes were made of Al and tunnel junctions were formed over the Al oxide layer. The coupling capacitances of the tunnel junctions, C ≈ 20 fF, in combination with the inductance of the 10 μm absorber create a bandpass filter with a central frequency around 300 GHz. Bolometers are integrated with log-periodic and double-dipole planar antennas made of Au. The temperature response of bolometer structures was measured at temperatures down to 256 mK. In our experiment we observed dV/dT=1.3 mV/K, corresponding to responsivity S=0.2.109 V/W. For amplifier noise Vna=3nV/Hz1/2 at 1 kHz the estimated total noise equivalent power is NEP=1.5.10-17 W/Hz1/2. The intrinsic bolometer self noise Vnbol=0.5 nV/Hz1/2 corresponds to NEP=3.10-18 W/Hz1/2. For microwave evaluation of bolometer sensitivity we used a black body radiation source comprising a thin NiCr stimulator placed on the cold plate of cryostat in front of a CC-HEB attached to an extended hemisphere sapphire lens. This measurements were consistent with estimates based on the dc responsivity of the bolometer.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 1, 2003•6 citations

Response of a cold-electron bolometer in a coplanar antenna system

Dmitry A. Pimanov, A. L. Pankratov, Anna V. Gordeeva +13 more

Abstract Cold-electron bolometers have shown suitability for use in modern fundamental physical experiments. In this study, the fabrication and measurements of the samples with cold-electron bolometers integrated into coplanar antennas are performed. The absorber layer was made using combined aluminum-hafnium technology to improve quality of aluminum oxide layer and decrease electron–phonon coupling. The samples of two types were measured in a dilution cryostat at various temperatures from 20 to 300 mK. The first sample with Ti/Au/Pd antenna shows response in the two frequency bands, at 7–9 GHz with bandwidth of about 20%, and also at 14 GHz with 10% bandwidth. The NEP below 10 aW Hz − 1 is reached at 300 mK for 7.7 GHz signal. The second sample with aluminum made antenna shows response in the frequency range 0.5–3 GHz due to the effect of kinetic inductance of superconducting aluminum.

arXiv:2412.07364•Superconductor Science and Technology•Feb 23, 2025•2 citations

A parallel/series array of superconducting cold-electron bolometers with SIS' tunnel junctions

L. S. Kuzmin

A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 17, 2008•3 citations

Optimal Cold-Electron Bolometer with a Superconductor-Insulator-Normal Tunnel Junction and an Andreev Contact

L. S. Kuzmin

A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.

•May 1, 2006•4 citations

Terahertz transmission spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, Evgueni Stepantsov +4 more

For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 8, 2004•3 citations
A novel type of the resonant cold-electron bolometer (RCEB) has been realized for multichroic pixels. The internal resonance is organized by a kinetic inductance of the NbN superconducting nanostrip and a capacitance of the superconductor-insulator-normal (SIN) tunnel junctions. The basic idea of a multichroic system is to combine a wideband antenna and narrow-band RCEBs. We used a single Lambda slot with two RCEBs for 75 and 105 GHz, placed in the middle. Each RCEB included two SIN junctions with absorber connected to NbN kinetic inductance of 420 and 240 pH. SIN junctions had capacitances of 11 and 8 fF. Wave impedance of the slot antenna was near 15 Ω and resistance of the absorber was matched to this value. Matching of antenna with an external system was done by placing Si lens on the back side of a Si substrate. RF testing was done at 300 mK irradiating this chip by sweep generator from 60 to 120 GHz. The response curves showed clear resonances at 75 and 105 GHz with quality factor of 10 and 7. Kinetic inductance value was estimated at the level of 35 pH/sq. These experiments confirmed that the RCEB can be effectively used to create multiband elements.
A novel type of resonant cold-electron bolometer (RCEB) is proposed. In this sensor, the internal resonance is organized by the kinetic inductance of an ultrasmall NbN superconducting nanostrip and the capacitance of the nanoscale superconductor-insulator-normal (SIN) tunnel junction. The size of kinetic inductance is about 300 times smaller than the size of geometrical inductance of the same value. This reduction of size gives an opportunity to create nanofilters with a total size considerably smaller than the wavelength. This internal resonance acts as a bandpass filter (instead of external filters) with a bandwidth of 3%-50%, something needed for radioastronomy applications. The use of NbN as Andreev contact material against escaping hot quasiparticles provides a unique opportunity to create an optimal CEB with only one SIN junction and an Andreev SN contact for thermal protection, in contrast to a classical CEB with two SIN junctions. The problem of hot quasiparticles escaping over the Andreev barrier (Δ) for Al electrode is overcome here by creating a barrier higher than quantum energy Δ > hf to have working kinetic inductance. Replacing two SIN junctions by one junction, we could use this junction of half the area to keep the same capacitive coupling. Therefore, a single-junction RCEB would have four times less area of junctions (and volume of absorber) in comparison with a two-junction RCEB and should show better noise performance due to the proportionally decreased e-ph (electron-phonon) noise component. The RCEB can be effectively used to create multiband elements that are actual tasks in submillimeter astronomy due to the benefit that comes from its ability to use co-located data, and problems with the dramatic increase of the size of the focal plane.
A capacitively coupled hot-electron nanobolometer (CC-HEB) is the simplest and most effective antenna-coupled bolometer. The bolometer consists of a small absorber connected to the superconducting antenna by tunnel junctions. The tunnel junctions used for high-frequency coupling also give perfect thermal isolation of hot electrons in the small volume of the absorber. The same tunnel junctions are used for temperature measurements and electron cooling. This bolometer does not suffer from the frequency limitations in the submillimeter range due to the high potential barrier of the tunnel junctions as does the microbolometer with Andreev mirrors (A-HEB), which is limited by the superconducting gap. Theoretical analyses show that the two-junction configuration more than doubles the sensitivity of the bolometer in current-biased mode compared to the single-junction configuration used for A-HEB. Another important advantage of CC-HEB is its simple two-layer technology for sample fabrication. Samples were fabricated with an absorber made of a bilayer of Cr and Al to match the impedance of the antenna. Electrodes were made of Al and tunnel junctions were formed over the Al oxide layer. The coupling capacitances of the tunnel junctions, C ≈ 20 fF, in combination with the inductance of the 10 μm absorber create a bandpass filter with a central frequency around 300 GHz. Bolometers are integrated with log-periodic and double-dipole planar antennas made of Au. The temperature response of bolometer structures was measured at temperatures down to 256 mK. In our experiment we observed dV/dT=1.3 mV/K, corresponding to responsivity S=0.2.109 V/W. For amplifier noise Vna=3nV/Hz1/2 at 1 kHz the estimated total noise equivalent power is NEP=1.5.10-17 W/Hz1/2. The intrinsic bolometer self noise Vnbol=0.5 nV/Hz1/2 corresponds to NEP=3.10-18 W/Hz1/2. For microwave evaluation of bolometer sensitivity we used a black body radiation source comprising a thin NiCr stimulator placed on the cold plate of cryostat in front of a CC-HEB attached to an extended hemisphere sapphire lens. This measurements were consistent with estimates based on the dc responsivity of the bolometer.
Abstract Cold-electron bolometers have shown suitability for use in modern fundamental physical experiments. In this study, the fabrication and measurements of the samples with cold-electron bolometers integrated into coplanar antennas are performed. The absorber layer was made using combined aluminum-hafnium technology to improve quality of aluminum oxide layer and decrease electron–phonon coupling. The samples of two types were measured in a dilution cryostat at various temperatures from 20 to 300 mK. The first sample with Ti/Au/Pd antenna shows response in the two frequency bands, at 7–9 GHz with bandwidth of about 20%, and also at 14 GHz with 10% bandwidth. The NEP below 10 aW Hz − 1 is reached at 300 mK for 7.7 GHz signal. The second sample with aluminum made antenna shows response in the frequency range 0.5–3 GHz due to the effect of kinetic inductance of superconducting aluminum.
A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.
A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.
For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.