Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Theoretical analysis of suppressing Dick effect in Ramsey-CPT atomic clock by interleaving lock

Xiaolin Sun, Jianwei Zhang, Pengfei Cheng, Yani Zuo, Lijun Wang

Published Feb 1, 2018• 6 citations
Publisher

Abstract

For most pulsed atomic clocks, the Dick effect is one of the main limits to reach its frequency stability limitation due to quantum projection noise. In this paper, we measure the phase noise of the local oscillator in the Ramsey-CPT atomic clock and calculate the Dick effect induced Allan deviation based on a three-level atomic model, which is quite different from typical atomic clocks. We further present a detailed analysis of optimizing the sensitivity function and minimizing the Dick effect by interleaving lock. By optimizing the duty circle of laser pulses, average time during detection and optical intensity of laser beam, the Dick effect induced Allan deviation can be reduced to the level of .

DOI
10.1088/1674-1056/27/2/023101

Related papers

Suppression of Dick Effect in the Ramsey-CPT atomic clock by Interleaving Lock

Xiaolin Sun, Jianwei Zhang, Pengfei Cheng +2 more

For most passive atomic clocks, the Dick effect is one of the main limits to reach its frequency stability limitation due to quantum projection noise. In this paper, we demonstrate that the minimization of the Dick effect for the Ramsey-CPT atomic clock can be accomplished by interleaving lock. By optimizing the duty circle of laser pulses, averaging time during detection and optical intensity of laser beam, the Dick effect induced Allan deviation can be reduced to the level of 10^-14.

arXiv:1707.07559•Jul 6, 2017•0 citations

Reduction of dick effect in a pulsed CPT vapor cell clock by interleaving lock

Xiaolin Sun, Pengfei Cheng, Yani Zuo +3 more

The Dick effect is one of the main limits for a passive atomic frequency standard to reach its frequency instability limit due to quantum projection noise. In this paper, we report on the reduction of Dick effect of a Ramsey-CPT vapor cell clock using interleaving lock. Three parameters are investigated in the process of optimizing sensitivity function in details. By optimizing the sensitivity function, the Dick effect induced Allan deviation (DEAD) can be reduced to the level of 10-14.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Dick effect in a pulsed atomic clock using coherent population trapping

Jean-Marie Danet, M. Lours, Stéphane Guérandel +1 more

The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.

arXiv:1406.6673•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Apr 1, 2014•63 citations

Dick Effect in a Microwave Frequency Standard Based on Laser-Cooled 113 Cd+ Ions

Jianwei Zhang, K. Miao, Lijun Wang

The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.

Chinese Physics Letters•Jan 1, 2015•13 citations

Minimizing the dick effect in an optical lattice clock

Philip G. Westergaard, Jérôme Lodewyck, P. Lemonde

We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a nondestructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 x 10(-16tau-1/2) for the lattice clock.

arXiv:0909.0909•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2010•57 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•17 citations
For most pulsed atomic clocks, the Dick effect is one of the main limits to reach its frequency stability limitation due to quantum projection noise. In this paper, we measure the phase noise of the local oscillator in the Ramsey-CPT atomic clock and calculate the Dick effect induced Allan deviation based on a three-level atomic model, which is quite different from typical atomic clocks. We further present a detailed analysis of optimizing the sensitivity function and minimizing the Dick effect by interleaving lock. By optimizing the duty circle of laser pulses, average time during detection and optical intensity of laser beam, the Dick effect induced Allan deviation can be reduced to the level of .
The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here, we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Because of its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally, this study permitted the choice of an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2 x 10-13at 1 s.
The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.
We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a nondestructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 x 10(-16tau-1/2) for the lattice clock.
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.