Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Thermal noise in high T(c) RF squids. 1. Experimental technique

Vladimir Polushkin, A.G. Likhachev

Published Jan 1, 1991• 0 citations
OpenAlex

Related papers

A thermal-activation model for intrinsic noise in RF pumped double SQUID'S

Boris Chesca

Physica C Superconductivity•Jan 1, 1996•5 citations

Intrinsic flux noise of high-Tc RF-SQUID in the dissipative mode

Xiaohui Wang, Jin Xin, Xixian Yao

Physica C Superconductivity•Oct 1, 1992•1 citation

Theory of RF SQUIDs Operating in the Presence of Large Thermal Fluctuations

Boris Chesca

Journal of Low Temperature Physics•Mar 1, 1998•53 citations

Effect of thermal fluctuation on the critical current of RF-SQUID in the dispersive mode

Xiaohui Wang, Xin Jin, Xinxian Yao

Physica C Superconductivity•May 1, 1991•0 citations

Measurements of thermal switching between metastable flux states in a RF-SQUID with intermediate damping

Maria Gabriella Castellano, Roberto Leoni, G. Torrioli +3 more

Applied Superconductivity•Jul 1, 1997•3 citations

Voltage-biased superconducting transition-edge bolometer with strong electrothermal feedback operated at 370 mK

Shih-Fu Lee, Jan M. Gildemeister, Warren A. Holmes +2 more

We present an experimental study of a composite voltage-biased superconducting bolometer (VSB). The tested VSB consists of a Ti-film superconducting thermometer (T(c) ~375 mK) on a Si substrate suspended by NbTi superconducting leads. A resistor attached to the substrate provides calibrated heat input into the bolometer. The current through the bolometer is measured with a superconducting quantum interference device ammeter. Strong negative electrothermal feedback fixes the bolometer temperature at T(c) and reduces the measured response time from 2.6 s to 13 ms. As predicted, the measured current responsivity of the bolometer is equal to the inverse of the bias voltage. A noise equivalent power of 5 x 10(-17) W/ radicalHz was measured for a thermal conductance G ~ 4.7 x 10(-10) W/K, which is consistent with the expected thermal noise. Excess noise was observed for bias conditions for which the electrothermal feedback strength was close to maximum.

Applied Optics•Jun 1, 1998•120 citations
We present an experimental study of a composite voltage-biased superconducting bolometer (VSB). The tested VSB consists of a Ti-film superconducting thermometer (T(c) ~375 mK) on a Si substrate suspended by NbTi superconducting leads. A resistor attached to the substrate provides calibrated heat input into the bolometer. The current through the bolometer is measured with a superconducting quantum interference device ammeter. Strong negative electrothermal feedback fixes the bolometer temperature at T(c) and reduces the measured response time from 2.6 s to 13 ms. As predicted, the measured current responsivity of the bolometer is equal to the inverse of the bias voltage. A noise equivalent power of 5 x 10(-17) W/ radicalHz was measured for a thermal conductance G ~ 4.7 x 10(-10) W/K, which is consistent with the expected thermal noise. Excess noise was observed for bias conditions for which the electrothermal feedback strength was close to maximum.