Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Investigation of dual species ions cloud by molecular-dynamics simulation for microwave clocks

Yani Zuo, Pengfei Cheng, Xiaolin Sun, L. J. Wang, Jianwei Zhang, L. J. Wang

Published Jul 1, 2017• 0 citations
Publisher

Abstract

A microwave atomic clock based on113Cd+ions at Tsinghua University is carried out for seven years. To further improve the performance of the clock, a new experimental setup with dual traps and dual species ions was proposed. To investigate the efficiency of sympathetic cooling and the dynamic process of ions, numerical simulation study of the dual-species ion ensembles by the Molecular-dynamics simulation is applied.

DOI
10.1109/fcs.2017.8088933

Related papers

Research On Sympathetic Cooling 113 Cd + - 174 Yb + System By Molecular Dynamics Simulation

S. N. Miao, Jianwei Zhang, N. C. Xin +6 more

A microwave ion clock based on113Cd+ions at Tsinghua University has been carried out for eleven years. To improve the performance of the ion clock with lower second-order Doppler frequency shift and suppressed Dick effect, a high-performance scheme for sympathetically cooling113Cd+ions based on molecular dynamics simulation is reported.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•2 citations

Progress of the dual-traps microwave frequency standard based on 113Cd+ ions

Yani Zuo, K. Miao, Changjun Gao +2 more

Microwave frequency standards based on ions have made great progress over the past decades; a microwave atomic clock based on laser cooled113Cd+ions at Tsinghua University is carried out for about five years. In order to further improve the performance of the clock, a new experiment setup with dual traps and two kinds of ions was proposed. This paper reports our recent experimental progress of the new dual-traps microwave frequency standard based on113Cd+ions.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2016•1 citation

Towards a high-performance microwave frequency standard based on 113Cd+ ions

Jianwei Zhang, K. Miao, Lijun Wang +2 more

Microwave frequency standards based on ions are promising as the next generation atomic clocks. This paper reports the recent progresses of the microwave frequency standard based on laser-cooled113Cd+ions developed at Tsinghua University. Based on the current experimental setup, the ground-state hyperfine splitting of113Cd+is measured with higher precision and a better short-term frequency stability is obtained than before. To improve the performance of the Cd+clock further, a new experimental setup with dual-traps is designed, and bi-ions operation is proposed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•3 citations

Progress Towards a Cadimium Ion Microwave Clock Based on Sympathetic Cooling

Yani Zuo, J. Z. Han, Lei Wei +2 more

The precision of Cadmium ion microwave clock based on linear quadrupole trap is mainly determined by the measurement accuracy of hyperfine splitting of the ground state of113Cd+. To reduce the second order Doppler frequency shift(SODFS), which is one of the main frequency shifts, we take advantages of sympathetic cooling by24Mg+ions to keep the Cadmium ion clouds at relatively low temperature during the interrogation of clock transition. By comparing the experiment results with molecular-dynamics(MD) simulation, we discuss the efficiency of sympathetic cooling and its influence on our clock's performance.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2018•3 citations

Progress Towards a Microwave Frequency Standard Based on Sympathetically-cooled 113Cd+ Ions

S. N. Miao, Jianwei Zhang, N. C. Xin +5 more

A microwave frequency standard based on113Cd+ions at Tsinghua University has been carried out for twelve years. To overcome the limitations of the Dick effect and the second-order Doppler frequency shift (SODFS), we propose to use heavy174Yb+as the coolant ions to sympathetically cool the large113Cd+cloud, which is expected to further improve the performance of the cadmium-ion microwave frequency standard. This paper reports our recent experimental and simulation progress towards the cadmium-ion microwave frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations

Precision Determination of the Ground-State Hyperfine Splitting in a 113Cd+ Microwave Clock

S. N. Miao, Y. H. Zheng, Yiting Chen +3 more

As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance$^{113}\text{Cd}^{+}$microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of$4.2\times 10^{-13}/\sqrt{\tau}$and a relative frequency uncertainty of$1.8\times 10^{-14}$, improving nearly three orders of magnitude compared to the result from JPL. The ground-state hyperfine splitting of$^{113}\text{Cd}^{+}$was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using$^{40}\text{Ca}^{+}$as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to$3.48\times 10^{-13}/\sqrt{\tau}$.

European Frequency and Time Forum•Jun 25, 2024•1 citation
A microwave atomic clock based on113Cd+ions at Tsinghua University is carried out for seven years. To further improve the performance of the clock, a new experimental setup with dual traps and dual species ions was proposed. To investigate the efficiency of sympathetic cooling and the dynamic process of ions, numerical simulation study of the dual-species ion ensembles by the Molecular-dynamics simulation is applied.
Microwave frequency standards based on ions are promising as the next generation atomic clocks. This paper reports the recent progresses of the microwave frequency standard based on laser-cooled113Cd+ions developed at Tsinghua University. Based on the current experimental setup, the ground-state hyperfine splitting of113Cd+is measured with higher precision and a better short-term frequency stability is obtained than before. To improve the performance of the Cd+clock further, a new experimental setup with dual-traps is designed, and bi-ions operation is proposed.
The precision of Cadmium ion microwave clock based on linear quadrupole trap is mainly determined by the measurement accuracy of hyperfine splitting of the ground state of113Cd+. To reduce the second order Doppler frequency shift(SODFS), which is one of the main frequency shifts, we take advantages of sympathetic cooling by24Mg+ions to keep the Cadmium ion clouds at relatively low temperature during the interrogation of clock transition. By comparing the experiment results with molecular-dynamics(MD) simulation, we discuss the efficiency of sympathetic cooling and its influence on our clock's performance.
A microwave frequency standard based on113Cd+ions at Tsinghua University has been carried out for twelve years. To overcome the limitations of the Dick effect and the second-order Doppler frequency shift (SODFS), we propose to use heavy174Yb+as the coolant ions to sympathetically cool the large113Cd+cloud, which is expected to further improve the performance of the cadmium-ion microwave frequency standard. This paper reports our recent experimental and simulation progress towards the cadmium-ion microwave frequency standard.
As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance113Cd+^{113}\text{Cd}^{+}113Cd+microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of4.2×10−13/τ4.2\times 10^{-13}/\sqrt{\tau}4.2×10−13/τ​and a relative frequency uncertainty of1.8×10−141.8\times 10^{-14}1.8×10−14, improving nearly three orders of magnitude compared to the result from JPL. The ground-state hyperfine splitting of113Cd+^{113}\text{Cd}^{+}113Cd+was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using40Ca+^{40}\text{Ca}^{+}40Ca+as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to3.48×10−13/τ3.48\times 10^{-13}/\sqrt{\tau}3.48×10−13/τ​.